The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

6151–6175 of 14963

  • HighNHTSA·20V461000·2020-08-06

    GM Recalls 2020 Chevrolet Corvette for Front Trunk Release Defect

    General Motors is recalling 2020 Chevrolet Corvette vehicles because the front trunk release button may fail to function after the vehicle is shut off for ten minutes, potentially trapping a person inside.

    Product
    CHEVROLET — CHEVROLET CORVETTE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V456000·2020-08-05

    Blue Bird Recalls 2021 School Buses Due to Steering Wheel Nut Issue

    Blue Bird is recalling 2021 Vision and All American school buses because the steering wheel nut may not be tightened properly, risking loss of control.

    Product
    BLUE BIRD — BLUE BIRD VISION SCHOOL BUS, ALL AMERICAN SCHOOL BUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V455000·2020-08-05

    Blue Bird Recalls 2021 Transit Buses Due to Steering Wheel Nut Issue

    Blue Bird is recalling 2021 Vision and All American transit buses because the steering wheel nut may not be properly tightened, risking loss of vehicle control.

    Product
    BLUE BIRD — BLUE BIRD VISION TRANSIT BUS, ALL AMERICAN TRANSIT BUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V459000·2020-08-05

    Kia Recalls 2019 Forte Vehicles Due to Axle Driveshaft Defect

    Kia is recalling 2019 Forte vehicles because the left front axle driveshaft may not have been heat-treated, which can cause it to break and increase crash risk.

    Product
    KIA — KIA FORTE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V458000·2020-08-05

    Thor Motor Coach Motorhomes Recalled: Pedestal Bolts May Fail During Crash

    Thor Motor Coach is recalling 2020-2021 Daybreak, 2018-2021 Four Winds, and 2018-2021 Chateau motorhomes because barrel chair pedestals are secured with bolts of the wrong size. In a crash, these pedestals could separate, causing seat belt anchorages to fail and increasing injury risk.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH redundant FOUR WINDS, redundant CHATEAU, DAYBREAK, FOUR WINDS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V453000·2020-08-04

    2019 Mercedes-Benz Sprinter Recalled for Fuel Pump Leak Risk

    Daimler Vans USA is recalling 2019 Mercedes-Benz and Freightliner Sprinter vans because an open port on the fuel pump may leak fuel onto the roadway, increasing crash risk.

    Product
    FREIGHTLINER — FREIGHTLINER, MERCEDES-BENZ SPRINTER (VS30)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V454000·2020-08-04

    Indian Recalls 2019 Scout Motorcycles Due to Brake Performance Issues

    Indian Motorcycle is recalling 2019 Scout, Scout Sixty, and Scout Bobber models because trapped air in the brake system may reduce performance and increase crash risk.

    Product
    INDIAN — INDIAN SCOUT BOBBER, SCOUT, SCOUT SIXTY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V451000·2020-08-03

    Triumph Recalls 2020 Tiger 900 Models for Detaching Rear Reflectors

    Triumph is recalling 2020 Tiger 900 motorcycles because rear reflectors may detach, reducing visibility and increasing crash risk.

    Product
    TRIUMPH — TRIUMPH TIGER 900 RALLY, TIGER 900, TIGER 900 GT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V452000·2020-08-03

    Bentley Recalls 2020 Flying Spur for Rear Camera Moisture Issue

    Bentley is recalling 2020 Flying Spur vehicles because moisture can enter the rear camera holder, reducing image clarity and increasing crash risk.

    Product
    BENTLEY — BENTLEY FLYING SPUR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V447000·2020-07-31

    Hyundai Recalls 2020 Genesis G70 for Steering Locking Risk

    Hyundai is recalling 2020 Genesis G70 vehicles because a steering component may be defective, potentially causing the steering to lock or become difficult to operate while driving.

    Product
    HYUNDAI — HYUNDAI GENESIS G70
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V449000·2020-07-31

    Mercedes-Benz Recalls Vehicles for Seat Belt Warning Software Defect

    Mercedes-Benz is recalling specific 2017-2019 models because instrument cluster software may cause the seat belt warning system to display a solid light instead of a blinking light with an audible tone.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ CLS 450, E 300, C 300, E 450
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V450000·2020-07-31

    Autocar Xpeditor Parking Brake May Apply Unexpectedly

    Certain 2018-2021 Autocar Xpeditor right-hand drive trucks may have improperly assembled parking brake plumbing, causing the brake to apply unexpectedly and increasing crash risk.

    Product
    AUTOCAR — AUTOCAR XPEDITOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20E052000·2020-07-30

    ZF Recalls Air Bag Crash Sensors in Chrysler and Volkswagen Vehicles

    ZF is recalling air bag crash sensors in 2019 Chrysler Jeep Cherokee and 2018 Volkswagen Atlas vehicles due to manufacturing defects that may delay or prevent air bag deployment.

    Product
    AIR BAGS recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V446000·2020-07-30

    GM Recalls 2020 Vehicles Due to Roof-Rail Air Bag Defect

    General Motors is recalling 2020 Buick, Cadillac, Chevrolet, and GMC vehicles because the roof-rail air bag inflator may separate during deployment, increasing injury risk.

    Product
    GMC — GMC, CHEVROLET, CADILLAC SIERRA 1500, SILVERADO 3500, SILVERADO 1500, SILVERADO 2500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V444000·2020-07-29

    Thor Motor Coach motorhomes recalled for faulty swivel seat wiring harnesses

    Certain 2020-2021 Thor motorhomes with swivel seats have wiring harnesses that may be routed incorrectly, potentially causing side airbags to deploy inadvertently or fail during crashes. Owners should contact Thor or Mercedes-Benz for free inspection and repair.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH GEMINI, COMPASS, redundant SYNERGY, CHATEAU CITATION
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V442000·2020-07-29

    Fleetwood Pace Arrow Motorhomes Recalled for Battery Fire Risk

    REV Recreation Group is recalling 2019-2020 Fleetwood Pace Arrow motorhomes because loose battery brackets may cause a short circuit and fire.

    Product
    FLEETWOOD — FLEETWOOD PACE ARROW
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V432000·2020-07-28

    High Altitude Trailer XT50 Recalled for Rear Swing Arm Weld Failure

    High Altitude Trailer is recalling 2019-2020 XT50 trailers with retrofitted rear swing arm spare tire carriers because a weld may fail, causing the tire to separate and increasing crash risk.

    Product
    HIGH ALTITUDE TRAILER — HIGH ALTITUDE TRAILER XT50
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20E051000·2020-07-28

    Meritor Recalls P220 and P579 Pressure Assemblies Due to Hose Fitting Defect

    Meritor is recalling specific pressure assemblies where an incorrect fitting may cause the power steering hydraulic hose to fail, resulting in a loss of steering assist.

    Product
    STEERING:HYDRAULIC POWER ASSIST:HOSE, PIPING, AND CONNECTIONS recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V434000·2020-07-28

    BMW Recalls 2019-2020 X5 and X6 M for Steering Column Defect

    BMW is recalling 2019-2020 X5 and 2020 X6 M vehicles because the steering column shaft bearing plate may not be properly attached, which can affect handling and increase crash risk.

    Product
    BMW — BMW X5, X6 M
    Category
    Vehicle
    Distribution
    Distributed nationwide