The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

3251–3275 of 14961

  • SevereNHTSA·23V382000·2023-05-30

    Alfa Romeo Giulia and Stelvio Recalled for Brake Rotor Fracture Risk

    NHTSA is recalling 2017-2020 Alfa Romeo Giulia and 2018-2020 Stelvio vehicles with carbon ceramic brakes due to a risk of rotor fracture and decreased brake performance.

    Product
    ALFA ROMEO — ALFA ROMEO GIULIA, STELVIO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V384000·2023-05-30

    2023 Toyota Corolla Cross instrument panel airbag deployment risk

    Toyota is recalling 2022-2023 Corolla Cross vehicles because the instrument panel may lack required perforations, preventing proper front-passenger airbag deployment in a crash.

    Product
    TOYOTA — TOYOTA COROLLA CROSS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V378000·2023-05-26

    Ford Recalls 2015-2019 Lincoln MKC for Engine Compartment Fire Risk

    Ford is recalling 2015-2019 Lincoln MKC vehicles because a battery monitor sensor may short-circuit and overheat, causing a fire in the engine compartment.

    Product
    LINCOLN — LINCOLN MKC
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V379000·2023-05-26

    Ford Vehicles Recalled for Incorrect Tire and Loading Capacity Label

    Ford is recalling certain 2019-2023 Ranger, 2022-2023 Bronco, and 2023 F-250 SD vehicles with TREAD labels stating incorrect load carrying capacity, which could result in vehicle overload and increase crash risk.

    Product
    FORD — FORD F-250 SD, RANGER, BRONCO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V380000·2023-05-26

    Ford Escape, Maverick, and Corsair Engine Fire Risk Recall

    Ford is recalling certain 2020-2023 Escape, 2022-2023 Maverick, and 2021-2023 Corsair vehicles due to a 2.5L engine defect that could cause an engine compartment fire. No injuries have been reported.

    Product
    FORD — FORD, LINCOLN MAVERICK, CORSAIR, ESCAPE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V376000·2023-05-26

    Travel trailers recalled for missing wardrobe cabinet backer board

    Certain 2021-2023 Keystone Arcadia travel trailers lack a backer board behind the wardrobe cabinet, potentially allowing the slide room to extend and cause injury. Dealers will install steel brackets to secure the slide room at no cost.

    Product
    KEYSTONE — KEYSTONE ARCADIA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V381000·2023-05-26

    Knapheide Recalls Vehicles with Warn Winches Due to Unintentional Operation Risk

    Knapheide is recalling 2022-2023 trucks equipped with certain Warn winches because water intrusion can cause the winch to operate unintentionally, increasing injury risk.

    Product
    KNAPHEIDE — KNAPHEIDE RAM 3500, FORD F-350, FORD F-250, FORD F-550
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V375000·2023-05-26

    Forest River Recalls 2023 East to West Travel Trailers Due to Gas Leak Risk

    Forest River is recalling 2023 East to West Della Terra and Silver Lake travel trailers because an incorrectly installed furnace may cause a gas leak inside the cabin.

    Product
    EAST TO WEST — EAST TO WEST DELLA TERRA, SILVER LAKE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V373000·2023-05-25

    2021-2023 Autocar Xpeditor trucks recalled for defective door latch

    Autocar is recalling 2021-2023 Xpeditor commercial trucks due to incorrectly assembled right-side door latches that may open unexpectedly during operation. Owners should contact Autocar for a free inspection and reassembly.

    Product
    AUTOCAR — AUTOCAR XPEDITOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V368000·2023-05-25

    Fontaine Recalls 2023-2024 Container Trailers Due to Missing Reflectors

    Fontaine Trailer Company is recalling 2023-2024 40-foot container trailers because they may be missing rear reflex reflectors, which reduces visibility and increases crash risk.

    Product
    FONTAINE — FONTAINE CONTAINER TRAILER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V367000·2023-05-25

    2023 Cadillac Lyriq Battery Connection Defect May Cause Loss of Drive Power

    General Motors is recalling certain 2023 Cadillac Lyriq and 2022 GMC Hummer EV vehicles. Connections in the high-voltage battery pack may be out of position or incorrectly welded, potentially causing loss of drive power and increasing crash risk.

    Product
    CADILLAC — CADILLAC, GMC LYRIQ, HUMMER EV PICKUP
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V374000·2023-05-25

    2023 Nissan Rogue rear seat belt fasteners may loosen in crashes

    Certain 2023 Nissan Rogue vehicles have rear seat belt anchor fasteners that may not have been properly tightened and could loosen over time, potentially failing to restrain occupants in a crash.

    Product
    NISSAN — NISSAN ROGUE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V369000·2023-05-25

    Jaguar I-PACE Battery Overheat May Increase Fire Risk

    Jaguar is recalling certain 2019-2024 I-PACE vehicles because the high-voltage battery may overheat, increasing the risk of fire. Owners should park and charge vehicles outside until repairs are complete.

    Product
    JAGUAR — JAGUAR I-PACE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V371000·2023-05-25

    IC Bus school buses recalled for ABS warning light failure

    IC Bus school buses (2021–2024) are being recalled because the anti-lock brake system warning light fails to illuminate during malfunctions, preventing drivers from being alerted and increasing crash risk.

    Product
    IC BUS — IC BUS CESB, RESB, EVSB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V370000·2023-05-25

    2022-2024 International Trucks: ABS Warning Light Fails to Illuminate

    Navistar is recalling certain 2021-2024 International trucks and buses whose anti-lock brake system warning light fails to illuminate when malfunctions occur. Drivers will not be alerted to brake system problems, increasing the risk of crashes.

    Product
    INTERNATIONAL — INTERNATIONAL, IC BUS LONESTAR, RH, LT, HX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23E040000·2023-05-24

    Veoneer Brake Booster Recall for Certain Honda Vehicles

    Veoneer is recalling brake booster assemblies in certain Honda vehicles because a tie rod fastener may be improperly assembled, risking brake failure.

    Product
    SERVICE BRAKES recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V365000·2023-05-24

    Loose Seat Belt Attachment in Winnebago and Itasca Motorhomes

    Winnebago and Itasca recall certain 2020-2023 motorhomes due to improperly tightened seat belt attachments that may fail to restrain occupants in a crash. Dealers will tighten fasteners free of charge.

    Product
    WINNEBAGO — WINNEBAGO, ITASCA INSPIRE, ADVENTURER, VISTA, SHELL
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V361000·2023-05-22

    Polestar Recalls 2020-2021 Polestar 1 Vehicles Due to Battery Fire Risk

    Polestar is recalling 2020-2021 Polestar 1 vehicles because defective high-voltage battery cells may overheat and cause a fire. Dealers will replace the battery pack free of charge.

    Product
    POLESTAR — POLESTAR POLESTAR 1
    Category
    Vehicle
    Distribution
    Distributed nationwide