Meritor Recalls Front Non-Drive Steer Axles Due to Tie Rod Clamp Cracking
Meritor is recalling certain Front Non-Drive Steer Axles because improperly heat-treated tie rod clamps may crack and separate, potentially causing a sudden loss of steering.
What this means for you
Our assessment, not the agency’s: severity 4/5 (Severe).
The hazard poses a serious risk of illness, injury, or structural failure. Stop using the product immediately and contact the manufacturer for a refund or repair.
Our severity reasoning: The recall involves a structural vehicle defect (tie rod separation) that can result in a sudden loss of steering and increased crash risk, which aligns with the 'Severe' criteria for structural vehicle defects.
Plain-English summary
Meritor, Inc. is recalling certain Front Non-Drive Steer Axles, specifically the FL941 and MFS Series. The recall addresses a defect where tie rod clamps may have been improperly heat-treated. This improper heat treatment can cause the clamps to crack, which allows the tie rods to separate.
The separation of the tie rods can result in a sudden loss of steering, which increases the risk of a crash. The source text does not specify the number of affected vehicles or the specific distribution scope.
Meritor will work with the affected manufacturers to replace the tie rod clamps free of charge. Owners may contact Meritor customer service at 1-866-668-7221. Meritor's number for this recall is C22AJ. Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.nhtsa.gov.
The recalled product
- Product
- STEERING:LINKAGES:TIE ROD ASSEMBLY recall
- Manufacturer
- Meritor, Inc.
- Category
- Vehicle — Steering Components
- Affected units
- 1,601
Distribution
Distributed nationwide across the United States.
Related recalls
Same manufacturer · Meritor, Inc.
See all →- SevereMeritor Recalls Front Steer Drive Axles Due to Bearing Damage Risk
NHTSA · 2024-12-09
- SevereMeritor Recalls Replacement Tie Rods Due to Heat-Treatment Defect
NHTSA · 2024-07-26
- SevereMeritor Recalls Front Drive Steer Axles Due to Fastener Loosening
NHTSA · 2023-04-11
- SevereMeritor Recalls Front Drive Steer Axles Due to Loose Fasteners
NHTSA · 2023-03-20
- SevereMeritor 180 Series Drive Pinions Recalled for Fracture Risk
NHTSA · 2022-03-29
Same hazard · loss of steering
See all →- SevereMack Recalls 2025 TerraPro Trucks Due to Steering Gearbox Fastener Issue
NHTSA · 2026-08-06
- SevereTenneco Recalls NAPA Steering Inner Tie Rod Ends for Ford Vehicles
NHTSA · 2026-07-10
- SevereBlue Arc BA4L-800 Recalled for Steering Gearbox Mounting Defect
NHTSA · 2026-02-17
- Severe
- SevereFord Bronco upper control arm ball joint fasteners may be missing
NHTSA · 2025-05-09
Similar recalls
- HighMeritor Recalls Front Non-Drive Axles Due to Tie Rod Torque Issue
NHTSA · 2015-02-19
- SevereMeritor Recalls Front Steer Axles Due to Missing Heat Treat Process
NHTSA · 2019-07-26
- SevereMeritor Recalls Front Drive Steer Axles Due to Fastener Loosening
NHTSA · 2023-04-11
- SevereMeritor Recalls Front Drive Steer Axles Due to Loose Fasteners
NHTSA · 2023-03-20
- SevereMeritor Recalls Replacement Tie Rods Due to Heat-Treatment Defect
NHTSA · 2024-07-26
- SevereMeritor Recalls Front Axles Due to Potential Heat Treatment Defect
NHTSA · 2016-06-06