MiniMed 780G Insulin Pump Software Anomaly Recall
Medtronic MiniMed's 780G Insulin Pump can stop delivering insulin due to a software anomaly when paired with the Instinct sensor, potentially leading to delayed therapy and increased risk of hyperglycemia or diabetic ketoacidosis.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: The recall involves a Class II medical device with a software defect that could delay critical insulin therapy and create risk of serious hyperglycemia or diabetic ketoacidosis. No illnesses or injuries have been reported, but the hazard is a known malfunction with potential for significant patient harm.
Plain-English summary
Medtronic MiniMed, Inc. is recalling the MiniMed 780G Insulin Pump (models MMT-1885, MMT-1886, MMT-1895, MMT-1896) due to a software anomaly in version 6.62. The pump can unexpectedly stop delivering insulin when paired with the Instinct sensor. When this occurs, the pump displays two error messages in sequence: Pump Error 53 followed immediately by Pump Error 23.
When insulin delivery stops, patients may experience delayed therapy and an increased risk of hyperglycemia or diabetic ketoacidosis (DKA). The affected devices have been distributed internationally to Spain, Great Britain, Netherlands, and Italy. A total of 778 units are subject to this recall.
Patients currently using the recalled pump models should contact Medtronic MiniMed, Inc. or consult their healthcare provider for guidance on next steps and potential replacement options.
The recalled product
- Product
- MiniMed 780G Insulin Pump, REF: MMT-1885, MMT-1886, MMT-1895, MMT-1896
- Manufacturer
- Medtronic MiniMed, Inc.
- Affected units
- 778
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (20)
- UDI-DI/GTIN: A7630006392701
- 00763000521554
- 00763000639273
- A7630006392301
- 00199150035687
- A7630007325603
- A7630007325601
- 00763000639235
- A7630007325604
- 00763000384289
- 00763000521530
- A7630007325401
- 00763000521547
- A7630006392601
- A7630006392201
- 00763000639228
- 00199150035663
- 00763000639266
- A7630007325404
- 00199150035694
Distribution
Distribution scope not specified by the agency.
Related recalls
Same manufacturer · Medtronic MiniMed, Inc.
See all →- SevereMedtronic MiniMed Flex Insulin Pumps Recalled for Failed Verification Tests
FDA (Devices) · 2026-10-14
- HighMedtronic MiniMed 780G Insulin Pumps Recalled for Chemical Damage Risk
FDA (Devices) · 2026-08-26
- SevereMedtronic MiniMed 670G Insulin Pumps Recalled Due to Chemical Damage Risk
FDA (Devices) · 2026-08-26
- HighMedtronic MiniMed 640G Insulin Pumps Recalled for Chemical Damage Risk
FDA (Devices) · 2026-08-26
- HighMiniMed Go App Recalled Due to Missed Insulin Alerts
FDA (Devices) · 2026-07-29
Same hazard · insulin delivery failure
See all →- HighInPen Smart Insulin Pen Recall Due to Incorrect Assembly
FDA (Devices) · 2025-04-30
- SevereVariSoft Infusion Set Model 1002828 Recalled for Connector Detachment Risk
FDA (Devices) · 2023-11-29
- HighTandem t:slim X2 Insulin Pump Battery Display May Cause Insulin Delivery Failure
FDA (Devices) · 2022-06-22
- HighTandem t:slim G4 Insulin Pump Recalled for Inaccurate Battery Readings
FDA (Devices) · 2018-07-25
- HighMedtronic MiniMed 620G Insulin Pump Recall for Motor Malfunction
FDA (Devices) · 2015-12-23
Similar recalls
- HighMedtronic MiniMed 780G software defects may cause insulin delivery inaccuracies
FDA (Devices) · 2026-04-01
- HighInsulin pumps recalled over errors that suspend insulin delivery
FDA (Devices) · 2026-02-11
- HighMiniMed 780G insulin pump delivery varies with pump height changes
FDA (Devices) · 2026-04-08
- HighMiniMed 780G Insulin Pump Software Fault Risks Overdose
FDA (Devices) · 2021-06-09
- SevereMiniMed Insulin Pumps Recalled for Battery Depletion and Delivery Risk
FDA (Devices) · 2024-10-09
- HighMiniMed 770G insulin pump delivery varies with pump height changes
FDA (Devices) · 2026-04-08