Pinnacle3 Radiation Therapy Planning System dose-calculation software error
Philips Pinnacle3 radiation therapy planning systems may export incorrect dose information when multiple beams are used with certain Edit Prescription settings. 169 systems are affected.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: This is an FDA Class II recall affecting a high-risk medical device (radiation therapy planning system) with a software bug that causes incorrect dose calculations. No injuries or illnesses have been reported, meeting the rubric criterion for 'risk-of-harm products where injury has not yet been reported'.
Plain-English summary
Philips Medical Systems (Cleveland) Inc is recalling 169 Pinnacle3 Radiation Therapy Planning System units (Models 870231 and 870237). The recall is due to a software error affecting dose calculation and export.
When computing a radiation dose in the system with multiple beams attached to a prescription and certain options selected on the Edit Prescription screen, the exported dose information is incorrect. This applies to Model 870231 (software versions 16.0.4, 16.4.2, and 16.4.3) and Model 870237 (software versions 16.4.6 and 18.0.1).
Affected systems were distributed across 20 US states (CA, FL, GA, IA, IL, MA, MD, ME, MI, MN, NJ, NM, NV, NY, OH, OK, RI, SC, TN, TX, WA) and 20 countries including Australia, Austria, Belgium, China, France, Germany, Italy, Japan, Jordan, Lebanon, Poland, Portugal, Romania, Russian Federation, Singapore, Spain, Switzerland, Taiwan, Thailand, and United Kingdom.
The recalled product
- Product
- Pinnacle3 Radiation Therapy Planning System, Model numbers 870231 and 870237.
- Manufacturer
- Philips Medical Systems (Cleveland) Inc
- Affected units
- 169
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (13)
- Model 870231: Software version 16.0.4
- UDI (01)00884838099081(10)16.0.4.60330
- Software version 16.4.2
- UDI (01)0084838103054(10)16.4.2.60330
- UDI (01)00884838102965(10)16.4.2.60330
- UDI (01)00884838102972(10)16.4.2.60315
- UDI (01)00884838102989(10)16.4.2.60330
- UDI (01)00884838103191(10)16.4.2.60330
- and Software version 16.4.3
- UDI (01)00884838102965(10)16.4.3.60360. Model 870237: Software version 16.4.6
- UDI (01)00884838103566(10)16.4.6.21197
- and Software version 18.0.1
- UDI (01)00884838103566(10)18.0.1.2149 and (01)00884838103566(10)18.0.1.21197.
Distribution
Related recalls
Same manufacturer · Philips Medical Systems (Cleveland) Inc
See all →- HighRadiation planning software recalled over image errors in three patient orientations
FDA (Devices) · 2025-09-24
- HighPinnacle 3 radiation planning software may miscalculate stopping power ratio
FDA (Devices) · 2025-08-13
- SeverePhilips Forte Gamma Camera System Recalled Due to Detector Falling Hazard
FDA (Devices) · 2019-11-13
- SeverePhilips Recalls Forte Gamma Camera Systems Due to Detector Fall Risk
FDA (Devices) · 2019-11-13
- SeverePhilips Forte Gamma Camera System Recalled for Detector Fall Hazard
FDA (Devices) · 2019-11-13
Same hazard · dose miscalculation
See all →- HighRayStation radiation therapy software recall for density calculation inconsistency
FDA (Devices) · 2025-02-26
- HighRadiotherapy Planning Software BeamAdjust and VeriSoft Recalled for Measurement Errors
FDA (Devices) · 2022-01-19
- HighMonaco RTP System software defect may cause incorrect radiation therapy dose calculations
FDA (Devices) · 2021-09-08
- SevereRaySearch Ray Station Software Recalled for Dose Miscalculations
FDA (Devices) · 2014-04-30
Similar recalls
- SeverePhilips Pinnacle3 Software Recall Due to Incorrect Dose Calculation
FDA (Devices) · 2015-05-27
- SeverePhilips Proton Therapy Planning Software Recalled for Dose Calculation Errors
FDA (Devices) · 2016-02-10
- HighPhilips Pinnacle3 Radiation Treatment Planning Software Recalled for Dose Inconsistency
FDA (Devices) · 2015-07-29
- HighPhilips Pinnacle3 Radiation Therapy Planning System Software Recall
FDA (Devices) · 2014-04-09
- HighPinnacle 3 radiation planning software may miscalculate stopping power ratio
FDA (Devices) · 2025-08-13
- ModeratePhilips Recalls Pinnacle3 Virtual Client Connection Software Due to Improper Release
FDA (Devices) · 2012-11-14