RaySearch Ray Station Software Recalled for Dose Miscalculations
RaySearch Laboratories is recalling Ray Station software versions 2.0 through 4.0 due to dose miscalculations for support structures on CT images.
What this means for you
Illness, injury, or structural failure has been reported. Stop using the product immediately and contact the manufacturer for a refund or repair.
Our severity reasoning: The recall is classified as FDA Class II, which corresponds to a 'Severe' rating under the rubric, particularly given the potential for significant injury due to radiation dose miscalculations.
Plain-English summary
RaySearch Laboratories AB has initiated a Class II recall for the RaySearch Ray Station Radiation Therapy Treatment Planning System, a stand-alone software product. The recall affects versions 2.0, 2.5, 3.0, 3.5, and 4.0.
The recall was issued because the software may miscalculate radiation doses for bolus, external, or fixation support structures when processing CT images. This defect could impact the accuracy of treatment planning for radiation therapy.
A total of 251 units are affected, with 148 units distributed domestically in the United States and 103 units distributed internationally. The software was distributed worldwide, including in the United States and various countries in Europe, Asia, and Oceania. Users of the affected software should contact RaySearch Laboratories for further instructions regarding the recall and potential corrective actions.
The recalled product
- Product
- RaySearch Ray Station Radiation Therapy Treatment Planning System, Stand-alone software. Versions 2.0, 2.5, 3.0, 3.5 and 4.0.
- Manufacturer
- RAYSEARCH LABORATORIES AB
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (8)
- Versions: 2.0.0.15
- 2.5.1.89
- 3.0.0.251
- 3.5.0.16
- 3.5.1.6
- 4.0.0.14
- 4.0.1.4
- 4.0.2.9.
Distribution
Related recalls
Same manufacturer · RAYSEARCH LABORATORIES AB
See all →- HighRayCare 2024A SP1 Oncology Information System Software Recall
FDA (Devices) · 2026-07-08
- HighRayCare 2024A SP4 Oncology System Beam Set Delivery Note Data Loss
FDA (Devices) · 2026-07-08
- HighRayStation 2024A treatment planning recalled over dose that fails to invalidate
FDA (Devices) · 2026-01-28
- HighRayStation 2023B and 2024A recalled over dose that fails to invalidate
FDA (Devices) · 2026-01-28
- HighRayStation v2025 treatment planning recalled over dose that fails to invalidate
FDA (Devices) · 2026-01-28
Same hazard · dose miscalculation
See all →- HighRayStation radiation therapy software recall for density calculation inconsistency
FDA (Devices) · 2025-02-26
- HighPinnacle3 Radiation Therapy Planning System dose-calculation software error
FDA (Devices) · 2022-09-21
- HighRadiotherapy Planning Software BeamAdjust and VeriSoft Recalled for Measurement Errors
FDA (Devices) · 2022-01-19
- HighMonaco RTP System software defect may cause incorrect radiation therapy dose calculations
FDA (Devices) · 2021-09-08