Solta Medical Recalls Thermage Face Tips Due to Sparking and Burn Risk
Solta Medical is recalling Thermage Face Tip 3.0 units because sparking during use could cause skin burns.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: The recall involves a risk-of-harm product (potential skin burns) where specific injury counts are not reported, fitting the High severity criteria for risk-of-harm products without reported injury.
Plain-English summary
Solta Medical Inc. is recalling 4,472 units of Thermage Face Tip 3.0, a medical device used in dermatologic and general surgical procedures for electrocoagulation and hemostasis. The recall was initiated due to complaints that the tips of the electrosurgical device spark during radiofrequency (RF) surgical procedures.
The use of the affected treatment tips could contribute to potential skin burns. The affected units are distributed in the United States (AK, AR, AZ, CA, FL, GA, IL, NY, PA, TX, UT, and WA) and internationally in Japan, Korea, Malaysia, Singapore, Taiwan, and Thailand.
Healthcare providers and consumers should stop using the affected Thermage Face Tip 3.0 units immediately. Solta Medical Inc. is the recalling firm responsible for managing the recall.
The recalled product
- Product
- Thermage Face Tip 3.0, REF/UDI: TTNS3,00C3-400/UDI (01)000850608002377; REF TTNS3.00C3-600/UDI (01)000850608002384; REF TTNS3.00C3-900; UDI (01)000850608002391 Used in dermatologic and general surgical procedures for electrocoagulation and hemostasis.
- Manufacturer
- Solta Medical Inc
- Hazard
- Affected units
- 4,472
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (20)
- Model Number /Lot Numbers: TTNS3.00C3-400: DOM 120519 011
- DOM 120419 014
- DOM 120219 008
- DOM 112619 006
- DOM 112019 010
- DOM 111519 004
- DOM 100819 005
- DOM 100119 005
- DOM 082319 003
- DOM 081919 007
- DOM 081419 004
- TTNS3.00C3-600: DOM 120419 018
- DOM 112019 009
- DOM 110119 010
- DOM 092319 005
- DOM 082219 015
- DOM 082119 006
- TTNS3.00C3-900: DOM 111819 005
- DOM 092319 006
- DOM 081419 005 Lot number/Number of Units Affected 120219-008/180
Distribution
Related recalls
Same manufacturer · Solta Medical Inc
See all →- ModerateThermage CPT System unit improperly tested and calibrated during manufacturing
FDA (Devices) · 2023-04-19
- HighSolta Medical Recalls VASER PRO Amplifiers Due to Burn Risk
FDA (Devices) · 2017-08-30
- SevereSolta Medical Recalls VASER Amplifiers Due to Burn Risk
FDA (Devices) · 2017-08-30
- ModerateSolta Medical Recalls Fraxel DUAL Laser Systems Due to Incorrect Labeling
FDA (Devices) · 2014-04-23
Same hazard · burn injury
See all →- SevereVQQQ Gas Patio Heaters Recalled for Fire and Burn Hazards
CPSC · 2026-10-22
- SevereSnow Peak Recalls Propane Fireplace Inserts and Lava Rocks
CPSC · 2026-10-08
- SevereHyundai and Genesis Recall Vehicles Due to Front Seat Fire Risk
NHTSA · 2026-10-08
- SevereDR Power Trimmer Mowers Recalled for Fire and Burn Hazards
CPSC · 2026-10-08
- SevereMedline Homecare Beds Recalled for Fire Hazard in Hand Control Pendant
FDA (Devices) · 2026-10-07
Similar recalls
- ModerateThermage CPT System unit improperly tested and calibrated during manufacturing
FDA (Devices) · 2023-04-19
- HighThermaCare HeatWraps Recalled for Potential Skin Burn Risk
FDA (Devices) · 2019-06-05
- HighSiemens Multix TOP X-ray Table Recalled Due to Fire Risk
FDA (Devices) · 2024-07-03
- SevereCutera truSculpt Infrared System Recalled for Thermal Burn Risk
FDA (Devices) · 2013-12-18
- HighBoston Scientific Recalls Habib EUS RFA Electrode Tips Due to Thermal Injury Risk
FDA (Devices) · 2019-12-18
- HighElekta Unity Radiation Therapy System Recalled for Heating Issues
FDA (Devices) · 2020-07-08