Medical Device Recall: Orthopedic Compression Screws with Incorrect Dimensions
In2Bones, SAS is recalling I.B.S Compression screws due to a batch mix-up. Affected screws may have different lengths than indicated on their labels, creating a risk of improper surgical implantation.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: FDA Class II recall for a medical device with dimensional mismatch on an orthopedic surgical implant. No injuries or illnesses reported in the source. Per the rubric, this constitutes a risk-of-harm medical device where injury has not yet been reported, warranting a High (3) severity score.
Plain-English summary
In2Bones, SAS is recalling I.B.S Compression screws (6.5mm diameter) due to a batch mix-up that resulted in incorrect product being distributed. Affected units may contain 75mm-length screws mislabeled as 80mm-length screws, or vice versa. The recall affects 63 units distributed nationwide in Tennessee. The affected batch (Batch Number 2306008, UDI/DI 3760225710692) has an expiration date of May 31, 2028.
Compression screws are orthopedic implants used in surgical procedures to provide fixation and support. A dimensional mismatch between the actual product and the label could result in the wrong implant being used during surgery, potentially compromising the surgical repair and patient safety.
Consumers and healthcare providers should immediately stop using the recalled units. Healthcare facilities should quarantine the affected batch and review patient records to identify whether any of these screws were already implanted. Patients who may have received these screws during surgery should contact their healthcare provider to determine if follow-up care is needed.
For more information, patients and providers may contact In2Bones, SAS or consult the FDA recall notice at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfres/res.cfm?id=Z-1320-2024.
The recalled product
- Product
- I.B.S¿ 6.5-C Compression screw - diam 6.5mm lg 80mm,Part Number S65 ST180
- Manufacturer
- In2Bones, SAS
- Affected units
- 63
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (3)
- UDI/DI 3760225710692
- Batch Number 2306008
- exp. 31/MAY/2028
Distribution
Part of a larger recall action
This product is one of 2 recalled by In2Bones, SAS under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.
See all 2 products in this recall →Related recalls
Same manufacturer · In2Bones, SAS
See all →- HighI.B.S. 6.5-C Compression Screw Batch Recalled for Dimensional Mix-Up
FDA (Devices) · 2024-03-27
- HighIn2Bones Shannon Percutaneous Burr Recalled for Potential Breakage During Use
FDA (Devices) · 2021-03-31
- HighIn2Bones Recalls Non-Locking Orthopedic Screws Due to Perioperative Breakage
FDA (Devices) · 2017-08-09
- ModerateIn2Bones Recalls NEOVIEW Screws Due to Thread Dimensional Non-Conformity
FDA (Devices) · 2017-01-18
- HighIn2Bones Recalls NEOVIEW Locking Screws Due to Thread Dimensional Non-Conformity
FDA (Devices) · 2017-01-18
Similar recalls
- ModerateIn2Bones Recalls Osteosynthesis Screws with Incorrect Torx Imprint
FDA (Devices) · 2015-12-16
- ModerateIntegra LifeSciences Recalls QWIX Compression Screws Due to Labeling Error
FDA (Devices) · 2016-08-31
- ModerateSynthes 3.0mm Headless Compression Screws Recalled for Labeling Mismatch
FDA (Devices) · 2018-10-31
- ModerateIn2bones Recalls NeoSpan Compression Staple Kits Due to Incorrect Drill Bit Size
FDA (Devices) · 2019-01-02
- ModerateSmith & Nephew Recalls Mislabelled Trigen Internal Hex Reconstruction Screws
FDA (Devices) · 2013-03-20
- ModerateSynthes 2.4 and 2.7 mm Locking Screws Recalled for Mislabeling
FDA (Devices) · 2013-12-04