The Recall Desk

Hazard

Dimension Mismatch recalls

9 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
9
Critical
0
Severe
0
Most recent
2026-09-23

Of the 9 dimension mismatch recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 0 (0%) are Severe.

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all dimension mismatch recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

1–9 of 9

  • HighFDA (Devices)·Z-1320-2024·2024-03-27

    Medical Device Recall: Orthopedic Compression Screws with Incorrect Dimensions

    In2Bones, SAS is recalling I.B.S Compression screws due to a batch mix-up. Affected screws may have different lengths than indicated on their labels, creating a risk of improper surgical implantation.

    Product
    I.B.S¿ 6.5-C Compression screw - diam 6.5mm lg 80mm,Part Number S65 ST180
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0846-2024·2024-02-07

    Cortera Spinal Fixation System screws recalled for incorrect dimensions

    XTANT Medical is recalling Cortera Spinal Fixation System screws that were manufactured with incorrect dimensions. Screws labeled 8.5 mm by 50 mm are actually 5.5 mm by 45 mm, potentially preventing proper screw engagement.

    Product
    Cortera Spinal Fixation System, REF: 150100-85050. Spinal fixation screws labeled as 8.5 mm diameter, 50 mm length.
    Category
    Medical Device
    Distribution
    1 state
  • ModerateFDA (Devices)·Z-1604-2023·2023-05-24

    Dental implant system recalled for incorrect package length labeling

    Hiossen Inc. is recalling 287 units of ET III Nano-HA dental implants due to incorrect package labeling stating implant length as 10mm when the actual length is 8.5mm. No illnesses or injuries have been reported.

    Product
    ET III Nano-HA fixture System ET NH Dental Implant Model # ET3R5010B -Intended for Dental Implant Catalog #: AET3R5010B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1246-2023·2023-03-22

    Synthes TFN-Advanced Femoral Nail Recalled for Dimensional Labeling Mismatch

    Synthes (USA) Products LLC is recalling TFN-Advanced Femoral Nails because labeled measurements do not match actual dimensions. Nails labeled 200mm may be 170mm and vice versa.

    Product
    TFN-Advanced Femoral Nail 12MM/125 DEG TI CANN TFNA 200MM STERILE. Intended for temporary fixation and stabilization of proximal femur fractures. Part Number: 04.037.213S
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1247-2023·2023-03-22

    TFN-Advanced Femoral Nails May Have Incorrect Length Markings

    Synthes TFN-Advanced Femoral Nails labeled as 200mm may measure 170mm, and vice versa. Healthcare providers should verify actual dimensions before surgical use.

    Product
    TFN-Advanced Femoral Nail 12MM/125 DEG TI CANN TFNA 170MM - STERILE. Intended for temporary fixation and stabilization of proximal femur fractures. Part Number: 04.037.212S
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1248-2023·2023-03-22

    TFN Femoral Nails dimensions mislabeled, may measure 170mm or 200mm

    Synthes recalled TFN-Advanced Femoral Nails because some units have incorrect dimensions: nails labeled 200mm may measure 170mm, while those labeled 170mm may measure 200mm. This dimensional mismatch could compromise surgical fixation.

    Product
    TFN-Advanced Femoral Nail 12MM/130 DEG TI CANN TFNA 170MM STERILE. Intended for temporary fixation and stabilization of proximal femur fractures Part Number: 04.037.242S
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0077-2022·2021-10-20

    Gore VIABAHN VBX endoprosthesis recalled for incorrect device dimension labeling

    W L Gore & Associates is recalling GORE VIABAHN VBX balloon expandable endoprosthesis units due to labeling showing incorrect device dimensions. Two units with specification mismatches were distributed to Italy and Lebanon.

    Product
    Heparin, GORE VIABAHN VBX, BALLOON EXPANDABLE ENDOPROTHESIS, REF BXAL085902E, 8 MM X 59 MM 8 Fr, LARGE BALLOON EXPANDLBE, Nominal Stent Diameter 8 mm, Max Post-Dilated Stent Diameter 16 mm, UDI:
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2170-2021·2021-08-11

    Stryker Nail Insertion Sleeve Recalled for Incorrect Inner Diameter

    Stryker is recalling Nail Insertion Sleeves with incorrect inner diameters that do not match the box label. The dimensional mismatch could affect proper fit during orthopedic surgical procedures.

    Product
    Nail Insertion Sleeve, elastic T2 Tibia SPI ¿8-13 (SPI Elast. Sleeve 8-13), Catalog Number 18061407S
    Category
    Medical Device
    Distribution
    Distributed nationwide