The Recall Desk
Agency classClass IIOur severity:HighFDA (Devices)·Z-0826-2024·Announced 2024-02-07

Custom Procedural Convenience Kits Recalled for Sterilization Validation Failure

American Contract Systems is recalling 244 custom procedural kits (Baby PICC, Pediatric PICC, and PORT PACK) distributed nationwide. Components subjected to sterilization without proper validation documentation may have reduced functionality or elevated sterilization residuals.

The agency’s classification

FDA (Devices): Class II

Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.

This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work

What this means for you

Our assessment, not the agency’s: severity 3/5 (High).

Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.

Our severity reasoning: This is an FDA Class II medical device recall with no reported hospitalizations, illnesses, or injuries. The hazards are theoretical—components may lose functionality or drug efficacy due to improper sterilization validation—but represent a risk-of-harm scenario. Per the rubric, recalls with unconfirmed hazards and no reported clinical incidents rate as High (Score 3).

Plain-English summary

American Contract Systems, Inc. is recalling custom procedural convenience kits distributed nationwide: Baby PICC Kit (kit numbers UIBP90J and UIBP90K), PORT PACK (kit number UIPO82AB), and Pediatric PICC Kit (kit number UIPP76K). The recall affects 244 units total.

During an internal investigation, the company identified that components were added to ACS sterilization trays and subjected to the ACS sterilization process. No documentation existed confirming these components were assessed for suitability to elevated temperatures for an extended period and to the sterilization process itself.

As a result, the components may have experienced loss or lack of functionality, loss of drug efficacy if applicable, or higher than specified ethylene oxide sterilization residuals. These conditions could affect the safety and effectiveness of the affected procedural kits.

The recall involves specific lot numbers with expiration dates ranging from July 2023 through April 2024. This is classified as a Class II recall by the FDA.

The recalled product

Product
Custom procedural convenience kits and trays, general hospital use, labeled as: a) Baby PICC Kit, kit number UIBP90J; b) Baby PICC Kit, kit number UIBP90K; c) PORT PACK (PS 058330), kit number UIPO82AB; d) Pediatric PICC Kit, kit number UIPP76K;
Affected units
244

Is your product affected?

Check your packaging against the codes below. If any of them match, the product is part of this recall.

Lot numbers (20)

  • a) UIBP90J
  • UDI/DI 00191072117038
  • Lot Numbers: 996231
  • exp. 1/4/2024
  • b) UIBP90K
  • UDI/DI 00191072189356
  • Lot Numbers: 911231
  • exp. 7/26/2023
  • c) UIPO82AB
  • UDI/DI 00191072172006
  • Lot Numbers: 727221
  • exp. 9/30/2023
  • 680221
  • exp. 11/16/2023
  • d) UIPP76K
  • UDI/DI 00191072142849
  • Lot Numbers: 637221
  • exp. 12/29/2023
  • 976231
  • exp. 1/24/2024

Distribution

Distributed nationwide across the United States.

Part of a larger recall action

This product is one of 18 recalled by American Contract Systems, Inc. under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.

See all 18 products in this recall →

Same manufacturer · American Contract Systems, Inc.