Varian On-Board Imager X-ray Generators Recalled for Missing Ground Wire
Varian Medical Systems is recalling 32 On-Board Imager systems because the X-ray generators are missing a required ground wire.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: The recall involves a missing safety ground wire on a medical device, which poses a risk of electrical shock or equipment malfunction, but the source text does not report any injuries or illnesses.
Plain-English summary
Varian Medical Systems, Inc. is recalling 32 units of the Varian On-Board Imager Advanced Imaging System. The recall is due to a defect identified by the X-ray generator supplier, CPI, where the VMS150 X-ray Generators were shipped without a ground wire connecting the EMI braid on the induction assembly cable to the ground stud on the lid of the High Voltage Module.
The affected devices are used to verify correct patient position in relation to the isocenter and to verify treatment fields in relation to anatomical and/or fiducial landmarks. The recall covers units distributed worldwide.
Healthcare facilities should contact Varian Medical Systems for instructions on how to resolve the missing ground wire issue.
The recalled product
- Product
- Varian On-Board Imager Advanced Imaging System. The On-Board Imager device is used for verification of correct patient position in relation to isocenter and verification of the treatment fields in relation to anatomical and/or fiducial land¿¿ marks.
- Manufacturer
- Varian Medical Systems, Inc.
- Affected units
- 32
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (1)
- Part Number P1003290001
Distribution
Distribution scope not specified by the agency.
Related recalls
Same manufacturer · Varian Medical Systems, Inc.
See all →- HighVarian Multileaf Collimator Recall Due to Software-Related Leaf Movement Failure
FDA (Devices) · 2020-05-13
- HighVarian Eclipse Treatment Planning System Proton Algorithm Recall
FDA (Devices) · 2019-01-30
- HighVarian Eclipse Treatment Planning System Software Recall for Contouring Errors
FDA (Devices) · 2017-01-18
- HighVarian Head Frame Posts Recalled Due to Rotation Risk
FDA (Devices) · 2016-10-19
- HighVarian AlignRT Plus Optical Surface Monitoring System Recall for Parameter Errors
FDA (Devices) · 2016-07-20
Same hazard · electrical shock
See all →- High
- Severe
- HighFort Defiance Automated Field Steam Sterilizer Recalled for Electrical Grounding Defect
FDA (Devices) · 2026-08-26
- SevereJayco Recalls 2026 Seismic Fifth Wheel Toy Haulers Due to Fire Risk
NHTSA · 2026-07-02
- Severe
Similar recalls
- ModerateVarian On-Board Imager Elbow Motor Shaft Recall
FDA (Devices) · 2014-04-30
- ModerateEos Imaging Recalls EOS X-ray Systems Due to Generator Failures
FDA (Devices) · 2012-10-10
- HighVarian VariSource iX Afterloader Systems Recalled for Calculation Errors
FDA (Devices) · 2015-07-08
- HighVarian AlignRT Plus Optical Surface Monitoring System Recall for Parameter Errors
FDA (Devices) · 2016-07-20
- HighVirtual Imaging Recalls Digital Mobile X-ray Systems Due to Motion Defect
FDA (Devices) · 2015-02-18
- HighVarian Optical Surface Monitoring System Recall for Unintended Couch Parameter Changes
FDA (Devices) · 2016-07-20