Medtronic Percept RC Implantable Neurostimulators Unable to Communicate with Programmer
Medtronic Percept RC implantable neurostimulators (Model B35300) may fail to communicate with the A610 DBS Clinician Programmer, displaying an 'Invalid Device' message. This prevents clinicians from adjusting therapy.
What this means for you
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: FDA Class II medical device with functional defect preventing programmer communication. No illnesses, injuries, or hospitalizations reported. Theoretical risk-of-harm scenario without reported adverse events scores at maximum 3 per the rubric.
Plain-English summary
Medtronic Neuromodulation is recalling Percept RC Implantable Neurostimulators, Model B35300. A limited number of these devices will not communicate with the A610 DBS Clinician Programmer Application upon use. When communication fails, an 'Invalid Device' message appears.
The recall involves 39 units distributed internationally to Germany, the United Kingdom, and Israel. The affected devices are identified by specific serial numbers and product codes documented in the official FDA recall notice.
The inability to communicate between the implanted neurostimulator and the programmer prevents clinicians from adjusting therapy settings and monitoring the device. This is an FDA Class II recall with no reported illnesses, injuries, or hospitalizations.
The recalled product
- Product
- Medtronic Percept RC Implantable Neurostimulators (INS), Model B35300.
- Manufacturer
- Medtronic Neuromodulation
- Hazard
- Affected units
- 39
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (20)
- GTIN 00763000813468
- Serial Numbers: NND504236H
- NND504252H
- GTIN 00763000813475
- Serial Numbers: NND504165H
- NND504169H
- NND504174H
- NND504181H
- NND504208H
- NND504212H
- NND504215H
- NND504216H
- NND504217H
- NND504218H
- NND504221H
- NND504222H
- NND504223H
- NND504224H
- NND504229H
- NND504230H
Distribution
Distribution scope not specified by the agency.
Related recalls
Same manufacturer · Medtronic Neuromodulation
See all →- ModerateMedtronic 1x4 pocket adaptor kits carry incorrect use-by dates
FDA (Devices) · 2026-06-03
- ModerateMedtronic 2x4 pocket adaptor kits carry incorrect use-by dates
FDA (Devices) · 2026-06-03
- HighMedtronic SynchroMed Flex Infusion Programmer Software Application
FDA (Devices) · 2026-05-20
- ModerateNeurostimulator clinician programmer app recalled over faults during device use
FDA (Devices) · 2026-01-21
- HighFemoral nails, 360 mm left trochanteric, recalled over undersized shaft diameter
FDA (Devices) · 2025-12-31
Same hazard · communication failure
See all →- ModeratePhilips Telemetry Monitor 5500 Device Reset Risk Recall
FDA (Devices) · 2026-07-01
- SevereEnhanced Verify Evaluation Handset May Fail to Connect to Neurostimulator
FDA (Devices) · 2025-05-07
- ModerateBeckman Coulter DxI 9000 Analyzer Communication Failure Recall
FDA (Devices) · 2025-03-26
- HighHospital Bed Fails to Send Remote Alerts Through Nurse Call System
FDA (Devices) · 2024-11-06
- HighArial Emergency Mobile App Restarts Cause Alert Overload and Call Failures
FDA (Devices) · 2024-06-12