The Recall Desk

Manufacturer

Entegra Coach

49 recalls in our database name Entegra Coach as the manufacturing or recalling firm.

What the numbers show

Total
49
Critical
0
Severe
23
Most recent
2022-12-02

Of the 49 recalls from Entegra Coach we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 23 (47%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

1–25 of 49

  • HighNHTSA·21V767000·2021-09-28

    Entegra Class A Motorhomes Recalled for Fuel Hose Leak Fire Risk

    Entegra Coach is recalling certain 2021-2022 Anthem, Aspire, and Reatta XL Class A motorhomes with Cummins diesel engines due to fuel hoses that may leak and pose a fire risk. Owners should contact Entegra customer service at 1-800-283-8267 for free replacement.

    Product
    ENTEGRA — ENTEGRA ANTHEM, REATTA XL, ASPIRE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V591000·2021-07-30

    Entegra Coach Motorhomes Recalled for Fuel Rail Sealing Defect

    Entegra Coach is recalling certain 2018-2022 Anthem, Aspire, Insignia, and Reatta XL motorhomes. A faulty sealing washer in the fuel rail assembly may leak, creating a fire risk. Contact Entegra Coach at 1-800-517-9137 for repairs.

    Product
    ENTEGRA — ENTEGRA REATTA XL, INSIGNIA, ASPIRE, ANTHEM
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V846000·2019-11-25

    Entegra Recalls 2018-2020 Qwest Motorhomes for Propane Tank Defect

    Entegra is recalling 2018-2020 Qwest motorhomes because defective propane tank hangers may allow the tank to dislodge, increasing crash and fire risk.

    Product
    ENTEGRA — ENTEGRA QWEST
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·19V436000·2019-06-11

    Entegra Recalls 2020 Motorhomes Due to Steering Shaft Bolt Issue

    Entegra is recalling 2020 Anthem and Cornerstone motorhomes because an insufficiently tightened steering shaft bolt may cause steering failure, increasing crash risk.

    Product
    ENTEGRA — ENTEGRA ANTHEM, CORNERSTONE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V265000·2019-04-02

    Entegra Recalls 2019 Vision and Emblem Motorhomes for Fire Risk

    Entegra Coach is recalling 2019 Vision and Emblem motorhomes because a missing fuse in the blower motor circuit may cause wiring to overheat and increase the risk of fire.

    Product
    ENTEGRA — ENTEGRA VISION, EMBLEM
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V178000·2019-03-06

    Entegra Recalls 2019-2020 Reatta Motorhomes for Damaged Tow Hitch

    Entegra Coach is recalling 2019-2020 Reatta motorhomes because the tow hitch may have been damaged during delivery, increasing the risk of a crash.

    Product
    ENTEGRA — ENTEGRA REATTA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V175000·2019-03-05

    Entegra Esteem Motorhomes Recalled for Parking Brake Cable Defect

    Entegra is recalling 2019 Esteem motorhomes because parking brake cable ends may be too small, allowing the cable to disconnect and preventing the emergency brake from engaging.

    Product
    ENTEGRA — ENTEGRA ESTEEM
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V124000·2019-02-25

    Entegra Reatta Motorhomes Recalled for Front Brake Defect

    Entegra is recalling 2019 Reatta motorhomes because missing or improper cotter pins on front brakes may reduce stopping power and increase crash risk.

    Product
    ENTEGRA — ENTEGRA REATTA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·18V687000·2018-10-02

    Entegra Recalls 2019 Motorhomes Due to Park Brake Defect

    Entegra is recalling 2019 Aspire, Anthem, and Insignia motorhomes because the park brake may fail to hold the vehicle on a grade.

    Product
    ENTEGRA — ENTEGRA INSIGNIA, ASPIRE, ANTHEM
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·18V688000·2018-10-02

    Entegra Recalls 2019 Motorhomes Due to Door Latch Adjustment Issue

    Entegra is recalling 2019 Anthem, Aspire, Cornerstone, and Insignia motorhomes because improperly adjusted entry door latch rods may allow the door to open during transit.

    Product
    ENTEGRA — ENTEGRA ASPIRE, ANTHEM, CORNERSTONE, INSIGNIA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V571000·2018-08-29

    Entegra Odyssey Recall: Damaged Hydraulic Hoses May Cause Fire

    Entegra Coach is recalling 2018 Odyssey vehicles because damaged leveling system hydraulic hoses may leak fluid onto the exhaust system, increasing the risk of a fire.

    Product
    ENTEGRA — ENTEGRA redundant ODYSSEY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·18V446000·2018-07-05

    Entegra Recalls 2019 Motorhomes for Windshield Wiper Defect

    Entegra is recalling 2019 Emblem and Vision motorhomes because windshield wiper arms may lift at highway speeds, reducing visibility and increasing crash risk.

    Product
    ENTEGRA — ENTEGRA EMBLEM, VISION
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·18V298000·2018-05-04

    Entegra Recalls 2019 Vision and Emblem Motorhomes for Wiper Defect

    Entegra is recalling 2019 Vision and Emblem motorhomes because the windshield wiper motor may fail in heavy snow or ice, reducing driver visibility.

    Product
    ENTEGRA — ENTEGRA VISION, EMBLEM
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V181000·2018-03-19

    Entegra Aspire Recalled for Power Steering Hose Fire Risk

    Entegra Coach is recalling 2011-2012 and 2015-2016 Aspire motorhomes because an incorrectly routed power steering hose may cause electrical arcing and a fire.

    Product
    ENTEGRA — ENTEGRA ASPIRE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V077000·2018-01-30

    Entegra Recalls Aspire and Insignia Motorhomes Due to Brake Reservoir Defect

    Entegra is recalling 2015-2018 Aspire and Insignia motorhomes because the air brake supply reservoir is undersized, which may reduce braking performance and increase crash risk.

    Product
    ENTEGRA — ENTEGRA INSIGNIA, ASPIRE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·17V752000·2017-11-22

    Entegra Recalls 2010-2011 RVs Due to Fire Extinguisher Defect

    Entegra is recalling 2010-2011 Aspire, Anthem, and Cornerstone RVs because the installed fire extinguishers may clog, require excessive force to activate, or have nozzles that detach.

    Product
    ENTEGRA — ENTEGRA CORNERSTONE, ASPIRE, ANTHEM
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·17V695000·2017-11-03

    Entegra Motorhomes Recalled for Missing Exterior Reflectors

    Entegra is recalling 2016-2018 Aspire, Anthem, Cornerstone, and Insignia motorhomes because they lack required reflectors, reducing visibility to other drivers.

    Product
    ENTEGRA — ENTEGRA ANTHEM, ASPIRE, INSIGNIA, CORNERSTONE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·17V441000·2017-07-13

    Entegra Recalls 2018 Cornerstone Motorhomes Due to Fuel Pump Defect

    Entegra is recalling 18 units of 2018 Cornerstone motorhomes because a fuel pump drive gear could slip, causing engine stalls and increasing crash risk.

    Product
    ENTEGRA — ENTEGRA CORNERSTONE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17V187000·2017-03-17

    Entegra Motorhomes Recalled for Front Suspension Ball Joint Separation Risk

    Entegra is recalling specific Aspire, Cornerstone, and Anthem motorhomes because front suspension ball joints may loosen and separate, potentially causing a loss of steering control.

    Product
    ENTEGRA — ENTEGRA CORNERSTONE, ANTHEM, ASPIRE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·16V873000·2016-12-05

    Entegra Recalls 2017 Cornerstone Vans Due to Collision System Defect

    Entegra is recalling 125 2017 Cornerstone vehicles because the collision mitigation system may be installed upside down, reducing its functionality and increasing crash risk.

    Product
    ENTEGRA — ENTEGRA CORNERSTONE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·16V827000·2016-11-15

    Entegra Recalls 2017 Motorhomes Due to Throttle Wire Interference

    Entegra is recalling 2017 Aspire, Anthem, Cornerstone, and Insignia motorhomes because throttle wires may not be twisted, causing unintended acceleration or deceleration.

    Product
    ENTEGRA — ENTEGRA CORNERSTONE, ANTHEM, ASPIRE, INSIGNIA
    Category
    Vehicle
    Distribution
    Distributed nationwide