The Recall Desk

Hazard

Wheel Separation recalls

116 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
116
Critical
0
Severe
105
Most recent
2026-10-02

Of the 116 wheel separation recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 105 (91%) are Severe.

Which agencies issued them

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all wheel separation recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

26–50 of 116

  • SevereNHTSA·19V835000·2019-11-20

    Isuzu and Chevrolet Trucks Recalled for Rear Wheel Lug Nut Defect

    Isuzu is recalling certain 2017-2020 Isuzu and Chevrolet trucks because rear outer wheel lug nuts may not have been properly tightened, increasing crash risk.

    Product
    ISUZU — ISUZU, CHEVROLET NPR HD, NPR XD, NQR, NRR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V630000·2019-08-28

    Pierce Recalls 2019 Tanker Vehicles Due to Front Axle Lubrication Defect

    Pierce Manufacturing is recalling one 2019 Pierce Tanker vehicle because insufficient front axle lubrication may damage wheel end bearings, potentially causing wheel separation and loss of control.

    Product
    PIERCE — PIERCE TANKER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V443000·2019-06-11

    Freightliner M2 and 108SD Trucks Recalled for Axle Lubrication Defect

    Daimler Trucks North America is recalling 2019-2020 Freightliner M2 and 2020 108SD trucks because insufficient axle lubrication may damage wheel bearings, increasing crash risk.

    Product
    FREIGHTLINER — FREIGHTLINER BUSINESS CLASS M2, 108SD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V422000·2019-06-06

    2020 International HV Trucks Recalled for Wheel Bearing Lubrication Defect

    Navistar is recalling 2020 International HV Severe Service Diesel Trucks because insufficient steer axle hub lubrication may cause wheel bearing damage and potential wheel separation.

    Product
    INTERNATIONAL — INTERNATIONAL HV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19E036000·2019-05-23

    Meritor recalls steer axles due to insufficient lubrication risk

    Meritor is recalling specific steer axles because insufficient lubrication may damage wheel end bearings, potentially causing wheel separation and loss of vehicle control.

    Product
    POWER TRAIN:AXLE ASSEMBLY recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V364000·2019-05-13

    LDJ Recalls 2019 Thunder Creek Trailers Due to Wheel Lug Nut Issues

    LDJ Manufacturing is recalling 102 2019 Thunder Creek trailers because wheel lug nuts may loosen, potentially causing a wheel to separate and increasing crash risk.

    Product
    THUNDER CREEK — THUNDER CREEK EV, SLT, MTT, FST
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19E028000·2019-04-12

    Cush Corp Recalls Trailer Axles Due to Wheel Separation Risk

    Cush Corp is recalling specific trailer suspension systems because a locking device may not be installed properly, allowing the wheel end to separate from the axle.

    Product
    SUSPENSION:REAR:AXLE:NON-POWERED AXLE ASSEMBLY recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V585000·2018-09-08

    Trailstar Recalls 2019 Dump Trailers Due to Wheel Separation Risk

    Trailstar is recalling 2019 Dump trailers because improperly installed wheel end nuts may cause the wheel to separate from the axle, increasing crash risk.

    Product
    TRAILSTAR — TRAILSTAR DUMP TRAILER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18E088000·2018-09-05

    AXN Heavy Duty Recalls Trailer Axles Due to Wheel Separation Risk

    AXN Heavy Duty LLC is recalling certain trailer axles because the wheel end nut locking device may not be properly installed, allowing the wheel end to separate from the axle.

    Product
    SUSPENSION:REAR:AXLE:NON-POWERED AXLE ASSEMBLY recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V567000·2018-08-28

    MAC Trailers Recalls 2019 Dump and Waste Trailers for Wheel Nut Defect

    MAC Trailer Mfg. is recalling 2019 Dump and Waste trailers because the wheel end nut locking device may not be properly installed, allowing the wheel end to separate from the axle.

    Product
    MAC TRAILERS — MAC TRAILERS WASTE TRAILER, DUMP TRAILER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V359000·2018-05-31

    Kenworth Recalls 2019 T270 and T370 Trucks for Axle Nut Issue

    PACCAR is recalling 2019 Kenworth T270 and T370 vehicles because over-tightened rear axle nuts may cause bearing failure or fire, increasing crash risk.

    Product
    KENWORTH — KENWORTH T270, T370
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V308000·2018-05-11

    Kenworth Recalls 2018 T270 Trucks Due to Front Wheel Hub Defect

    PACCAR is recalling 2018 Kenworth T270 trucks because an incorrectly installed front wheel hub component may cause bearing failure and wheel separation.

    Product
    KENWORTH — KENWORTH T270
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V206000·2018-03-29

    Spartan Gladiator Recall for Front Axle Spindle Failure Risk

    Spartan Motors is recalling 2004-2007 Gladiator emergency response vehicles because front axle spindles may crack and fail, potentially causing a wheel to separate.

    Product
    SPARTAN — SPARTAN GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18E017000·2018-03-29

    Timoney Front Suspension Recall Due to Axle Spindle Fatigue Cracks

    Timoney Technology is recalling Mark 1 and Gen 2 Independent Front Suspensions because inconsistent machining may cause axle spindle failure and wheel separation.

    Product
    SUSPENSION:FRONT recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V172000·2018-03-14

    KME Predator Fire Apparatus Recalled for Front Axle Spindle Defect

    Kovatch Mobile Equipment is recalling specific KME Predator fire apparatus vehicles because inconsistent machining may cause front axle spindles to crack and fail, potentially leading to wheel separation.

    Product
    KME — KME PREDATOR TANKER, PREDATOR RESCUE, PREDATOR AERIAL, PREDATOR PUMPER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17E048000·2017-08-28

    Ford Recalls Wheel Hub Bearings for 2011-2017 Explorer 4X2 Vehicles

    Ford is recalling certain wheel hub bearing assemblies for 2011-2017 Ford Explorer 4X2 vehicles because they lack a self-retention feature, which could cause the wheel to separate.

    Product
    FORD — FORD EXPLORER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17E042000·2017-08-01

    Timken Recalls Rear Hub Unit Bearings for Ford Explorers

    Timken is recalling specific rear hub unit bearings for 2011-2017 Ford Explorer 4X2 vehicles because they lack a self-retention feature, which could cause the wheel to separate.

    Product
    SUSPENSION:REAR recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17V311000·2017-05-11

    Toyota Recalls Tundra and Sequoia for Cracking Lugnuts

    Toyota is recalling 2013-2017 Tundra and Sequoia vehicles with specific aftermarket wheels because lugnuts may crack and detach, increasing crash risk.

    Product
    TOYOTA — TOYOTA SEQUOIA, TUNDRA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V634000·2016-08-31

    Daimler Trucks Recalls 2014-2017 Models Due to Front Axle Hub Failure Risk

    Daimler Trucks North America is recalling specific 2014-2017 Freightliner and Western Star trucks because front axle hubs may fail, causing the wheel to separate from the axle.

    Product
    WESTERN STAR — WESTERN STAR, FREIGHTLINER 4800, 5700, 108SD, CASCADIA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V319000·2016-05-18

    Autocar Recalls 2016-2017 Xpert and Xspotter Trucks for Rear Axle Defect

    Autocar is recalling 43 model year 2016-2017 Xpert and Xspotter trucks because improperly bent tab lock washers may allow rear axle spindle nuts to loosen, potentially causing the wheel assembly to separate.

    Product
    AUTOCAR — AUTOCAR XPERT, XSPOTTER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V661000·2015-10-15

    Chrysler Recalls 2015-2016 Ram 1500 Trucks for Rear Axle Defect

    Chrysler is recalling 2015-2016 Ram 1500 trucks because rear axles may have been incorrectly heat treated, potentially causing a fracture and wheel separation.

    Product
    RAM — RAM 1500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V331000·2015-06-01

    Van Hool Recalls Coaches Due to Front Steering Knuckle Breakage Risk

    Van Hool is recalling specific 2014-2015 coaches because the front steering knuckle carrier may break, potentially causing the wheel to separate and increasing crash risk.

    Product
    VAN HOOL — VAN HOOL CX45, TD925, TDX25, TX40
    Category
    Vehicle
    Distribution
    Distributed nationwide