The Recall Desk

Hazard

Software Fault recalls

93 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
93
Critical
0
Severe
15
Most recent
2026-07-30

Of the 93 software fault recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 15 (16%) are Severe.

Which agencies issued them

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all software fault recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

1–25 of 93

  • SevereNHTSA·26V498000·2026-07-30

    Winnebago Ekko Motorhomes Recalled Over Generator Software Fault

    Winnebago is recalling certain 2024-2025 Ekko motorhomes because the touchscreen display may register unintended inputs and turn the generator on without the operator's knowledge.

    Product
    WINNEBAGO — WINNEBAGO EKKO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1573-2026·2026-03-25

    Welch Allyn vision screener display may flicker inducing photosensitive seizures

    Baxter is recalling the Welch Allyn Spot Vision Screener VS100 on software version 3.2.0.1 because the display screen may unintentionally flicker, which may induce photosensitive seizure activity.

    Product
    Brand Name: Welch Allyn, Inc. Product Name: Welch Allyn Spot Vision Screener VS100 Model/Catalog Number: VS100 Software Version: Software version 3.2.0.1 Product Description: Welch Allyn Spot Vision Screener VS100, FDA product code name: Refractometer, ophthalmic One unit pe
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·26V185000·2026-03-25

    Volkswagen Jetta and Taos instrument panels may not display warnings

    Volkswagen is recalling certain 2025 Jetta and Taos vehicles because the instrument panel may fail to display warning lights or gauges. This fails FMVSS 101.

    Product
    VOLKSWAGEN — VOLKSWAGEN JETTA, TAOS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26V165000·2026-03-18

    Ford and Lincoln image module resets can disable rearview camera

    Ford is recalling certain 2022-2025 Lincoln Navigator, Nautilus, Aviator and Explorer vehicles because the Image Processing Module A may reset unexpectedly, losing the rearview camera image and driver assistance features.

    Product
    LINCOLN — LINCOLN, FORD NAVIGATOR, NAUTILUS, EXPLORER, AVIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26V112000·2026-02-26

    Honda Prologue and Acura ZDX instrument and camera displays may fail

    Honda is recalling certain 2024 Acura ZDX and Prologue vehicles because a software error may cause the instrument panel display to fail and the rearview camera to show a blank screen in reverse.

    Product
    HONDA — HONDA, ACURA PROLOGUE, ZDX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1383-2026·2026-02-25

    Bronchoscopy robots recalled over arms that may move toward patient-left

    Auris Health is recalling 173 MONARCH Platform bronchoscopy systems because a software restart can re-initialize the system to patient-left, leading to unanticipated robotic arm positioning.

    Product
    MONARCH Platform, Bronchoscopy, Catalog Numbers: MON-000005-01 , MON-000005-01R , MON-000006 , MON-000006-RFB, MON-000008 with software
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1345-2026·2026-02-18

    Azurion 3 M15 systems recalled over tables that may move unexpectedly

    Philips is recalling 802 units of the Azurion 3 M15 because the table may move unexpectedly when the Reset Geometry button is pressed, even with a table lock active.

    Product
    Azurion 3 M15 System Model Numbers: (1) 722064, (2) 722222, (3) 722230, (4)722280(OUS only); Software Version Number - All versions: R1.X, R2.X, R3.X
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1339-2026·2026-02-18

    GammaPlan 11.1 recalled over plans that may irradiate the wrong location

    Elekta is recalling Leksell GammaPlan version 11.1 because an error when defining a new stereotactic reference may produce a treatment plan that irradiates the incorrect patient location.

    Product
    Brand Name: Leksell GammaPlan Product Name: Radionuclide RT Treatment planning system Software Version: 11.1 Product Description: Leksell GammaPlan¿ is a computer-based system designed for Leksell Gamma Knife¿ treatment planning.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1340-2026·2026-02-18

    GammaPlan software recalled over plans that may irradiate the wrong location

    Elekta is recalling Leksell GammaPlan versions 11.3 and 11.4 because an error when defining a new stereotactic reference may produce a treatment plan that irradiates the incorrect patient location.

    Product
    Brand Name: Leksell GammaPlan Product Name: Radionuclide RT Treatment planning system Software Version: 11,3, 11.4 Product Description: Leksell GammaPlan¿ is a computer-based system designed for Leksell Gamma Knife¿ treatment planning.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1347-2026·2026-02-18

    Azurion 7 B20 systems recalled over tables that may move unexpectedly

    Philips is recalling 1 of the Azurion 7 B20 because the table may move unexpectedly when the Reset Geometry button is pressed, even with a table lock active.

    Product
    Azurion 7 B20 System Model Numbers: (1)722068, (2)722226, (3)722236; Software Version Number - All versions: R1.X, R2.X, R3.X
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1349-2026·2026-02-18

    Azurion 7 M20 systems recalled over tables that may move unexpectedly

    Philips is recalling 5 of the Azurion 7 M20 because the table may move unexpectedly when the Reset Geometry button is pressed, even with a table lock active.

    Product
    Azurion 7 M20 System Model Numbers: (1)722079, (2)722224, (3)722234, (4)722282(OUS only); Software Version Number - All versions: R1.X, R2.X, R3.X
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1350-2026·2026-02-18

    Azurion 5 M12 systems recalled over tables that may move unexpectedly

    Philips is recalling 326 units of the Azurion 5 M12 because the table may move unexpectedly when the Reset Geometry button is pressed, even with a table lock active.

    Product
    Azurion 5 M12 System Model Numbers: (1)722227, (2)722231; Software Version Number - All versions: R1.X, R2.X, R3.X
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1348-2026·2026-02-18

    Azurion 7 M12 systems recalled over tables that may move unexpectedly

    Philips is recalling 1 of the Azurion 7 M12 because the table may move unexpectedly when the Reset Geometry button is pressed, even with a table lock active.

    Product
    Azurion 7 M12 System Model Numbers: (1)722078, (2)722223, (3)722233; Software Version Number - All versions: R1.X, R2.X, R3.X
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1344-2026·2026-02-18

    Azurion 3 M12 systems recalled over tables that may move unexpectedly

    Philips is recalling 291 units of the Azurion 3 M12 because the table may move unexpectedly when the Reset Geometry button is pressed, even with a table lock active.

    Product
    Azurion 3 M12 System Model Numbers: (1) 722063, (2) 722221, (3) 722229; Software Version Number - All versions: R1.X, R2.X, R3.X
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1351-2026·2026-02-18

    Azurion 5 M20 systems recalled over tables that may move unexpectedly

    Philips is recalling 922 units of the Azurion 5 M20 because the table may move unexpectedly when the Reset Geometry button is pressed, even with a table lock active.

    Product
    Azurion 5 M20 System Model Numbers: (1)722228, (2)722232, (3)722281(OUS only); Software Version Number - All versions: R1.X, R2.X, R3.X
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1346-2026·2026-02-18

    Azurion 7 B12 systems recalled over tables that may move unexpectedly

    Philips is recalling 655 units of the Azurion 7 B12 because the table may move unexpectedly when the Reset Geometry button is pressed, even with a table lock active.

    Product
    Azurion 7 B12 System Model Numbers:(1) 722067, (2) 722225, (3) 722235; Software Version Number - All versions: R1.X, R2.X, R3.X
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V083000·2026-02-12

    Chevrolet and GMC transmission control valve failure may lock rear wheels

    GM is recalling certain Chevrolet Silverado and GMC Sierra vehicles that may have been repaired incorrectly under recall 24V797, because the transmission control valve may fail and lock the rear wheels.

    Product
    CHEVROLET — CHEVROLET, GMC SILVERADO 1500, SIERRA 1500, SILVERADO 2500, SILVERADO 3500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26V084000·2026-02-12

    International truck software may fail to brake with adaptive cruise

    International is recalling certain 2026-2027 MV vehicles because the ECU software may fail to engage the brakes when adaptive cruise control or hill hold assist is in use.

    Product
    INTERNATIONAL — INTERNATIONAL MV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1235-2026·2026-02-11

    Sample preparation systems recalled over a software dispensing error

    Beckman Coulter is recalling 50 CellMek SPS Sample Preparation Systems because a software error dispenses samples close to or touching tube bottoms, removing 60-100 microliters from the final sample.

    Product
    CellMek SPS Sample Preparation System, REF: C44603, with software
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1238-2026·2026-02-11

    Insulin pumps recalled over errors that suspend insulin delivery

    Medtronic MiniMed is recalling 577 MiniMed 780G insulin pumps on software version 6.60 because a timing and processor communication issue may trigger Pump Error 43 or 41, suspending insulin delivery.

    Product
    MiniMed 780G Insulin Pump Catalog Numbers: MMT-1884 MMT-1886 With Software Version 6.60 The MiniMed 780G insulin pump is indicated for use by patients age 7-80 years with Type 1 diabetes, whose total daily dose of insulin is 8 units per day or more. The MiniMed 780G system
    Category
    Medical Device
    Distribution
    45 states
  • HighFDA (Devices)·Z-1232-2026·2026-02-11

    Surgical robots recalled over a software error hiding failed arm diagnostics

    Intuitive Surgical is recalling 219 da Vinci X, Xi and da Vinci 5 systems because a software error allowed instrument arms failing an important diagnostic test to remain in clinical use.

    Product
    Brand Name: Da Vinci Product Name: da Vinci X, Xi Surgical System, & da Vinci 5 Surgical System Model/Catalog Number: IS4000; IS4200; IS5000 Software Version: N/A Product Description: The da Vinci Xi, X, and da Vinci 5 surgical systems each consist of three main components:
    Category
    Medical Device
    Distribution
    30 states
  • HighFDA (Devices)·Z-1175-2026·2026-02-04

    Q.namix T fluoroscopy systems recalled over unflipped and mismatched images

    Siemens is recalling 7 units of the LUMINOS Q.namix T fluoroscopic X-ray system because ortho images may not be flipped as preset and an image of a previous patient may be processed.

    Product
    Interventional Fluoroscopic X-Ray System: LUMINOS Q.namix T; Siemens Material Number (SMN): 11574003; With Software Version VB10D-SP02
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1179-2026·2026-02-04

    Q.namix R fluoroscopy systems recalled over unflipped and mismatched images

    Siemens is recalling 41 units of the LUMINOS Q.namix R fluoroscopic X-ray system because ortho images may not be flipped as preset and an image of a previous patient may be processed.

    Product
    Alphenix INFX-8000V, interventional fluoroscopic x-ray system
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1202-2026·2026-02-04

    A.T.S. 3200TS tourniquets recalled over screens that may freeze

    Zimmer Surgical is recalling 51 A.T.S. 3200TS Tourniquet Systems because the user interface may freeze or become unresponsive to touch in certain non-English language settings.

    Product
    Brand Name: Zimmer Tourniquet Systems Product Name: A.T.S.¿ 3200TS Tourniquet Systems Model/Catalog Number: 60320010100 Software Version: Software version v2.06 or prior are within scope of the recall for A.T.S.¿ 3200TS Product Description: A.T.S 3200TS Tourniquet Systems Co
    Category
    Medical Device
    Distribution
    0 states