Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all electrical short recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

26–50 of 382

  • SevereNHTSA·25V332000·2025-06-06

    Volvo Recalls 2025-2026 VN Trucks for Power Cable Routing Defect

    Volvo Trucks North America is recalling 2025-2026 Volvo VN trucks because improperly routed power cables may cause electrical shorts, leading to engine stalls or fires.

    Product
    VOLVO — VOLVO VN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V291000·2025-05-06

    2025 Hyundai Palisade vehicles recalled for electric oil pump fire risk

    Hyundai is recalling certain 2025 Palisade vehicles because an insufficient seal on the electric oil pump controller can allow moisture to accumulate and cause an electrical short that may result in fire. Owners should park vehicles outside and away from structures until the repair is completed.

    Product
    HYUNDAI — HYUNDAI PALISADE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V261000·2025-04-18

    Motiv Recalls F-53 and F-59 Chassis Due to Bracket Failure Risk

    Motiv Power Systems is recalling 2019-2022 F-53 and F-59 chassis vehicles because a support bracket may break, causing an electrical short and loss of drive power.

    Product
    MOTIV — MOTIV F-53 BEV CHASSIS, F-59 BEV CHASSIS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V258000·2025-04-17

    Autocar Recalls 2023-2024 Xspotter Vehicles Due to Wiring Fire Risk

    Autocar is recalling 2023-2024 Xspotter vehicles because a misrouted alternator ground cable may contact the positive stud, causing damage and increasing the risk of a fire.

    Product
    AUTOCAR — AUTOCAR XSPOTTER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1529-2025·2025-04-16

    Beckman Coulter DxI 9000 Immunoassay Analyzer Electrical Short Risk

    Beckman Coulter is recalling certain DxI 9000 Access Immunoassay Analyzer units due to ground screws on PCB boards that may cause electrical shorts, leading to smoke and delayed patient test results.

    Product
    DxI 9000 Access Immunoassay Analyzer, catalog number C11137 in vitro diagnostic device used for the quantitative, semi-quantitative, or qualitative determination of various analyte concentrations found in human body fluids
    Category
    Medical Device
    Distribution
    0 states
  • SevereNHTSA·25V238000·2025-04-11

    Ford Recalls 2024-2025 E-Transit Chassis Due to Battery Fire Risk

    Ford is recalling 2024-2025 E-Transit Chassis vehicles because battery tray rails may crack, allowing water entry that could cause a fire.

    Product
    FORD — FORD E-TRANSIT CHASSIS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V055000·2025-03-25

    Volvo Recalls 2023-2025 VNR Electric Trucks Due to Battery Fire Risk

    Volvo Trucks North America is recalling 2023-2025 VNR Electric trucks because loose hardware in the high-voltage battery may cause a short circuit and fire.

    Product
    VOLVO — VOLVO VNRE (ELECTRIC)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·25703·2024-12-05

    Polaris RZR XP Off-Road Vehicles Recalled Due to Fire Hazard

    Polaris is recalling about 21,000 RZR XP 1000 and XP 4 1000 recreational off-road vehicles because the battery terminal cover can be damaged by the seat base, exposing the battery post and creating a fire hazard. No injuries have been reported.

    Product
    Model Year 2024-2025 RZR XP 1000 and XP 4 1000 ROVs
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V863000·2024-11-15

    2025 Grand Design Lineage motorhomes recalled for faulty battery warming pad

    2025 Lineage motorhomes may have incorrectly installed battery warming pads that can damage wiring and cause electrical shorts with fire risk. Grand Design will replace the pads free of charge.

    Product
    GRAND DESIGN — GRAND DESIGN LINEAGE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V783000·2024-10-18

    Rimac Nevera Recalled for Potential Electrical Cable Fire Risk

    Rimac is recalling 2023-2024 Nevera vehicles because a low-voltage cable may not be secured properly, posing a fire risk. Owners are advised not to drive until inspected.

    Product
    RIMAC — RIMAC NEVERA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0051-2025·2024-10-16

    Endoscopy and Bronchoscopy Systems Power Cord Defect Risk

    Monarch Platform endoscopy and bronchoscopy systems may have defective power cords causing electrical shorts and shock risk if exposed wires are touched, potentially leading to system shutdown.

    Product
    Monarch Platform (Endoscopy), REF: MON-000005-01, MON-000005-01R. Monarch Platform (Bronchoscopy), REF: MON-000006, MON-000006-RFB.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·24V672000·2024-09-16

    2024 Harley-Davidson Motorcycles Recalled for Electrical Short Circuit Risk

    Harley-Davidson is recalling certain 2024 motorcycles because the voltage regulator output wire may rub on the crankcase, causing an electrical short circuit. This could result in loss of electrical and drive power while riding, increasing crash risk.

    Product
    HARLEY-DAVIDSON — HARLEY-DAVIDSON FLHX, FLTRX, FLTRXSE, FLHXSE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V685000·2024-09-13

    2024 Ford Explorer Hybrid: Fire Risk from Battery Cable Chafing

    Ford is recalling certain 2024 Ford Explorer vehicles with 3.3L Hybrid engines due to a defect in which the 12-Volt battery cable may chafe against the high voltage cable and short circuit, increasing fire risk. No injuries have been reported.

    Product
    FORD — FORD EXPLORER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2586-2024·2024-08-21

    Heated Eye Mask Recalled Due to Detachable Wires and Burn Risk

    EYE COMFORT CARE LLC is recalling the UNclog Eye Mask due to safety clips that may allow wires to detach, potentially causing electrical shorts and burn injuries.

    Product
    Brand Name: UNclog Eye Mask Product Name: UNclog Eye Mask Model/Catalog Number: AG23JW24 Serial # ag22 Product Description: Heated eye mask Component: Heating unit, wire
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V608000·2024-08-13

    BMW Recalls Multiple Models Due to Water Pump Electrical Fire Risk

    BMW is recalling 720,796 vehicles from 2012-2018 because an improperly sealed water pump connector may short circuit, increasing the risk of a fire.

    Product
    BMW — BMW 328I, 228XI, Z4, X3
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V577000·2024-08-01

    Jayco Recalls 2024-2025 Entegra Motorhomes Due to Battery Cable Fire Risk

    Jayco is recalling 2024-2025 Entegra motorhomes because improperly sized or installed battery cables may overheat or short, increasing the risk of a fire.

    Product
    ENTEGRA — ENTEGRA CORNERSTONE, REATTA XL, ANTHEM, ASPIRE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V437000·2024-06-13

    Ram 1500 Recall: Rearview Camera Wiring Harness Defect

    Chrysler is recalling one 2022 Ram 1500 Classic because a wiring harness short may prevent the rearview camera from displaying, increasing crash risk.

    Product
    RAM — RAM 1500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V412000·2024-06-05

    2024 Hyundai Tucson and Santa Cruz power steering defect recall

    Hyundai is recalling 2024 Tucson and Santa Cruz vehicles due to a potential circuit board short in the power steering system. Loss of steering assist could increase crash risk.

    Product
    HYUNDAI — HYUNDAI TUCSON, SANTA CRUZ
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V310000·2024-05-01

    Jayco Terrain and Entegra Launch Motorhomes Recalled for Wiring Chafing Hazard

    Jayco and Entegra recall certain 2023-2024 motorhomes with a wiring harness that may chafe against the drive shaft, causing short circuit and risking loss of steering, braking, and drive power, plus fire.

    Product
    ENTEGRA — ENTEGRA, JAYCO LAUNCH, TERRAIN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V308000·2024-05-01

    2024 Hyundai Kona electrical short can cause loss of drive power

    Hyundai is recalling 2024 Kona, Elantra, and Venue vehicles because an electrical short in the EGR valve can cause loss of drive power. Dealers will replace the assembly free of charge.

    Product
    HYUNDAI — HYUNDAI VENUE, ELANTRA, KONA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V166000·2024-03-01

    Mercedes-Benz Recalls 2023 Sprinter Vans Due to Wiring Harness Fire Risk

    Daimler Vans USA is recalling 2023 Mercedes-Benz Sprinter vans because the main wiring harness may chafe and short circuit, increasing the risk of fire and loss of vehicle control.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ SPRINTER 4500, SPRINTER 2500, SPRINTER 3500, SPRINTER 1500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V107000·2024-02-13

    Hyundai Recalls Genesis Models Due to Starter Solenoid Fire Risk

    Hyundai is recalling certain 2015-2019 Genesis vehicles because water in the starter solenoid can cause an electrical short and engine fire.

    Product
    HYUNDAI — HYUNDAI, GENESIS GENESIS, G80, G90, G70
    Category
    Vehicle
    Distribution
    Distributed nationwide