Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

35476–35500 of 40489

  • ModerateFDA (Devices)·Z-2044-2014·2014-07-23

    MTI Precision Products Recalls Lynx TM20 Torquemaster Low Speed Handpieces

    MTI Precision Products LLC is recalling 134 Lynx TM20 Torquemaster Low Speed Handpieces due to a sharp edge on the body or housing.

    Product
    Lynx TM20 Torquemaster Low Speed Handpiece MTI Dental Products
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2071-2014·2014-07-23

    Siemens RAPIDComm Data Management System Recalled for Incorrect Test Names

    Siemens Healthcare Diagnostics Inc is recalling six RAPIDComm Data Management Systems because the 5.0 screen layout displays incorrect test names.

    Product
    Siemens RAPIDComm¿ Data Management System. The RAPIDComm¿ Data Management System manages the process of sending and receiving data from Siemens POC devices and hospital systems located in the hospital network,
    Category
    Medical Device
    Distribution
    2 states
  • ModerateFDA (Devices)·Z-2042-2014·2014-07-23

    Siemens e.cam camera systems recalled for loose rear casters

    Siemens Medical Solutions USA is recalling 2,458 e.cam camera systems because the collimator cart rear casters may become loose.

    Product
    e.cam camera system. Emission Computed Tomography System used to detect or image the distribution of radionuclides in the body or organ, using the following techniques: planar imaging, whole body imaging, tomographic imaging for isotopes with energies up to 588 keV. Nuclear…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-2041-2014·2014-07-23

    BBL CrystaLEAD E/NF Identification Kits Recalled for Incorrect Expiration Dates

    Becton Dickinson is recalling specific lots of BBL CrystaLEAD E/NF Identification kits because some contain fluid bottles that expire before the date printed on the kit carton.

    Product
    BBL CrystaLEAD Enteric/Nonfermentor (E/NF) Identification (ID) System, catalog number 245000. in vitro diagnostic for the identification of aerobic gram-negative bacteria that belong to the family Enterobacteriaceae as well as some of the more frequently isolated glucose…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1994-2014·2014-07-16

    Intuitive Surgical Recalls Patient Side Cart Battery Boxes for Overheating Risk

    Intuitive Surgical is recalling 2,606 Patient Side Cart Battery Boxes used with the da Vinci A surgical system because they may overheat and bulge during charging.

    Product
    Patient Side Cart Battery Box used in conjunction with the da Vinci A surgical system. Intuitive Surgical Inc. Sunnyvale, CA 94086
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-2023-2014·2014-07-16

    Invacare Aquatec Fixed Backrest Recalled for Structural Failure Risk

    Invacare is recalling 465 Aquatec Fixed Backrests because they may detach from the frame under uneven load, posing a risk of injury.

    Product
    Aquatec Fixed Backrest - accessory for Mobile Shower and Toilet commode Aquatec Ocean, Ocean VIP and Ocean E-VIP family.
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-2034-2014·2014-07-16

    Zimmer Hip Joint Prosthesis Recalled for Black Residue in Sterile Pouches

    Zimmer, Inc. is recalling 852 units of M/L Taper Reduced Neck hip joint prostheses because black residue was observed in the sterile pouches.

    Product
    Zimmer M/L Taper Reduced Neck Standard & Extended Offset, HIP JOINT PROSTHESIS, Sizes:4, 5, 6, 7.5, 9, 10, 11 & 12.5. The femoral stem component of a modular system that consists of an acetabular component, femoral head, femoral stem, and the instrumentation necessary…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2022-2014·2014-07-16

    B. Braun Stopcock Extension Sets Recalled for Reverse Assembly Defect

    B. Braun Medical is recalling 10,835 Stopcock Extension Sets because some stopcocks are assembled in reverse, causing them to close when set to open.

    Product
    STOPCOCK EXT. SET W/ 3-WAY STOPCOCK WITH INJ. SITE AND SPINLOCK CONNECTOR, 22 inches and 37 inches
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2038-2014·2014-07-16

    Pall Medical Breathing Circuit Filter Recall for Possible Air Leak

    Pall Corporation is recalling specific lots of Medical Breathing Circuit Filters due to a possible leak at the filter end cap junction.

    Product
    PALL Medical Breathing Circuit Filter, REF BB50T and BB50T-BULK , Rx ONLY Single use, bi-directional bacterial/viral removal filter. The filters are individually packaged in a clear, plastic pouch with black writing - 50 per case, or in bulk packaged 100 filters/bag and two…
    Category
    Medical Device
    Distribution
    15 states
  • HighFDA (Devices)·Z-1996-2014·2014-07-16

    RGI Medical Recalls 300psi I.V. Catheter Extension Sets

    RGI Medical is recalling 19,200 units of Henora 300psi I.V. Catheter Extension Sets due to a defect that may cause the tubing to separate from the luer connection during use.

    Product
    Henora REF: 70-4026-09V1 300psi I.V. Catheter Extension Set Product Usage: Catheter extension set for high pressure procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2001-2014·2014-07-16

    Vascular Technology Recalls VTI Bayonet Doppler Probes Due to Sterility Concerns

    Vascular Technology, Inc. is recalling 25 VTI Bayonet Doppler probes because the sterile barrier may have been penetrated, potentially rendering the devices unsterile.

    Product
    VTI BAYONET DOPPLER, 20MHz DOPPLER PROBE, SLIM, BX 4, REF 108660 The Doppler probe is intended for the intraoperative and transcutaneous evaluation of blood flow.
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-1999-2014·2014-07-16

    Mizuho Doppler Probe Recalled Due to Sterile Barrier Penetration

    Vascular Technology, Inc. is recalling 147 Mizuho Doppler Probes because the sterile barrier was penetrated, potentially rendering the devices unsterile.

    Product
    07-150-10 MIZUHO, DOPPLER PROBE, SLIM, BX 4, REF 138660 The Doppler probe is intended for the intraoperative and transcutaneous evaluation of blood flow.
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-2000-2014·2014-07-16

    Vascular Technology Recalls Sterile Doppler Probes Due to Barrier Penetration

    Vascular Technology, Inc. is recalling 34 sterile Doppler probes because the sterile barrier may have been penetrated, potentially rendering the devices unsterile.

    Product
    07-150-12 MIZUHO, MINI, SLIM, STERILE, BOX OF 4, REF 138665 The Doppler probe is intended for the intraoperative and transcutaneous evaluation of blood flow.
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-2002-2014·2014-07-16

    3M Attest Auto-reader Recalled for Missing Dry Natural Rubber Labeling

    3M is recalling Attest Auto-readers because labels failed to disclose dry natural rubber content, posing an allergy risk.

    Product
    3M Attest Auto-reader. Model numbers 390, 390G,and 490. These devices incubate the biological indicators (BIs) to determine a positive or negative result for the sterilization cycle.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2027-2014·2014-07-16

    Hospira MedNet Software Recall for Dosing Unit Transmission Defect

    Hospira is recalling 13 units of MedNet MMS software due to a defect that may fail to send specific dosing units to infusion pumps.

    Product
    The Hospira MedNet Medication Management Suite (MMS). Product Usage: The Hospira MedNet Medication Management Suite (MMS) is intended to facilitate networked communication between MMS compatible computer systems and Hospira infusion pumps. The MMS provides trained healthcare…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2026-2014·2014-07-16

    Steris 4085 General Surgical Table Recalled for Pressure Switch Defect

    Steris Corporation is recalling 3,689 STERIS 4085 General Surgical Tables because a defective pressure switch may cause the hand control to incorrectly indicate that floor lock feet are locked.

    Product
    The STERIS 4085 General Surgical Table Product Usage: is an electro-hydraulically operated surgical table designed to support all general surgical procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2025-2014·2014-07-16

    CareFusion Recalls SmartSite Infusion Sets Due to Unlabeled Filter

    CareFusion is recalling SmartSite Low Sorbing Infusion Sets because the drip chamber contains a 15-micron filter not listed in the instructions, posing a risk of occlusion if used with blood.

    Product
    SmartSite Low Sorbing Infusion Set, Model Codes: 10014855A, 10015861A, 10061661A 14035457 14035485 14046894 14035458
    Category
    Medical Device
    Distribution
    5 states
  • HighFDA (Devices)·Z-1998-2014·2014-07-16

    Mizuho Disposable Doppler Probe Recalled for Sterile Barrier Penetration

    Vascular Technology, Inc. is recalling 164 Mizuho disposable Doppler probes because the sterile barrier was penetrated, potentially rendering the product unsterile.

    Product
    07-150-07 MIZUHO, MAL DISP DOPPLER PROBE BX 4, REF 138200 The Doppler probe is intended for the intraoperative and transcutaneous evaluation of blood flow.
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-2035-2014·2014-07-16

    Zimmer M/L Taper Hip Prosthesis Recalled Due to Black Residue

    Zimmer, Inc. is recalling M/L Taper Hip Prostheses with Kinectiv Technology because black residue was observed in the sterile pouches.

    Product
    Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology, HIP JOINT PROSTHESIS¿, Sizes:4, 5, 6, 7.5, 9, 10, 11 & 12.5. The femoral stem component of a modular system that consists of an acetabular component, femoral head, femoral stem, and the instrumentation necessary…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2039-2014·2014-07-16

    Karl Storz Recalls Essential NEO Audio/Visual Units Due to Overheating Cable

    Karl Storz Endoscopy is recalling 968 Essential NEO audio/visual integration units because the connected power cable could overheat, generate smoke, and cause the peripheral to stop working.

    Product
    Essential NEO, Audio/Visual Integration Unit An audio/visual integration unit.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1995-2014·2014-07-16

    Cenorin HLD System Model 610 Recalled for Temperature Sensor Defect

    Cenorin is recalling 25 HLD System Model 610 units because a temperature sensor defect may prevent water from heating during pasteurization.

    Product
    HLD System, Model 610, Medical Device Cleaning and High Level Disinfection Washer/Pasteurizer.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1997-2014·2014-07-16

    FDA Recalls Devon Surgical Positioning Kits Due to Strap Separation Risk

    The FDA is recalling 264 Devon Supine, Lithotomy and Trendelenburg Positioning Kits because straps may separate from the foam pad.

    Product
    Devon Supine, Lithotomy and Trendelenburg Positioning Kit; Product Code: 31151090 Product Usage: The device is intended to provide padding under the patient, and help maintain the position of an anesthetized patient during surgery.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2020-2014·2014-07-16

    Intuitive Surgical Recalls Large Clip Applier Instruments Due to Jamming Risk

    Intuitive Surgical is recalling Large Clip Applier instruments used with da Vinci S and SI systems because a manufacturing defect may cause the instrument to jam during insertion.

    Product
    Intuitive Surgical Inc. Large Clip Applier instruments used in conjunction with da Vinci S and da Vinci SI Surgical Systems Intuitive Surgical Inc., 'Sunnyvale, CA 94086
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2033-2014·2014-07-16

    Zimmer M/L Taper Hip Stem Recall Due to Black Residue

    Zimmer, Inc. is recalling M/L Taper Hip Stems because black residue was observed in the sterile pouches. The recall covers 1,487 units distributed worldwide.

    Product
    Zimmer M/L Taper Hip Stem Standard & Extended Offset, HIP JOINT PROSTHESIS, Sizes: 5.0, 7.5, 9.0, 10.0, 11.0, 12.5, 13.5, 15.0, 11.25, 17.25, 20.0 & 22.5. The femoral stem component of a modular system that consists of an acetabular component, femoral head, femoral stem…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2040-2014·2014-07-16

    Codan Recalls ColorSafe IV Lines Manufactured Before FDA Approval

    Codan US Corporation is recalling ColorSafe IV lines because they were manufactured and marketed prior to FDA approval.

    Product
    ColorSafe IV lines Catalog No.(Model No.) CS3000-R (76.7806), CS400-R (76.7800), CS408N-R (76.8000), CS3000-B (76.7807), B314 (25.7406), CS400-B (76.7801), CS408N-B (76.8001), CS3000-O (76.7808), CS400-O (76.7802), CS408N-O (76.8002), CS3000-G (76.7809)…
    Category
    Medical Device
    Distribution
    3 states