The Recall Desk

Agency

National Highway Traffic Safety Administration

NHTSA oversees recalls of vehicles, tires, child seats, and motor-vehicle equipment. Each campaign is identified by an NHTSA campaign number.

Visit the official NHTSA site →

About NHTSA recalls

NHTSA regulates the safety of every motor vehicle sold in the US plus tires, child seats, and motor-vehicle equipment. Recalls are coordinated under a numbering scheme called the NHTSA Campaign Number — a string like 25V123000 where the first two digits are the year, V is for vehicle (T is for tires, C for child seats, E for equipment), and the rest identifies the campaign. Every vehicle in our database can be looked up by VIN to check whether any active campaigns affect it.

NHTSA recalls are unusual in two ways. First, the cause is usually a defined defect or non-compliance with a Federal Motor Vehicle Safety Standard rather than a pathogen or contamination event — so 'severity' tracks the consequence of the defect (does the airbag fail to deploy, does the steering lose assist, does the fuel tank leak) rather than reported illnesses. Second, every NHTSA recall is mandatory for the manufacturer to remedy at no charge to the owner, for as long as the vehicle is on the road. There's no expiration on a NHTSA campaign.

We enrich every recall with the full make / model / year-range affected so you can see at a glance whether your vehicle is in scope. If you're not sure, the VIN lookup decodes your specific vehicle and cross-references the database. The remedy is always free — usually a dealer visit for a part replacement, software update, or inspection.

6976–7000 of 15405

  • SevereNHTSA·19V848000·2019-11-26

    Forest River Recalls 2020 XLR Boost Trailers Due to Axle Defect

    Forest River is recalling 2020 XLR Boost trailers because an undersized axle and tire combination may cause the trailer to be overloaded, increasing the risk of a crash.

    Product
    FOREST RIVER — FOREST RIVER XLR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V844000·2019-11-25

    Forest River Recalls 2018-2020 Cascade and Cherokee Travel Trailers

    Forest River is recalling 2018-2020 Cascade and Cherokee travel trailers because the trailer hitch coupler may fail, potentially causing the trailer to detach from the tow vehicle.

    Product
    FOREST RIVER — FOREST RIVER CASCADE, CHEROKEE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V845000·2019-11-25

    Jayco Melbourne Prestige Motorhomes Recalled for Propane Tank Defect

    Jayco is recalling 2018-2020 Melbourne Prestige motorhomes because defective propane tank hangers may allow the tank to dislodge, increasing crash and fire risk.

    Product
    JAYCO — JAYCO MELBOURNE PRESTIGE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V846000·2019-11-25

    Entegra Recalls 2018-2020 Qwest Motorhomes for Propane Tank Defect

    Entegra is recalling 2018-2020 Qwest motorhomes because defective propane tank hangers may allow the tank to dislodge, increasing crash and fire risk.

    Product
    ENTEGRA — ENTEGRA QWEST
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V842000·2019-11-22

    TransTech School Buses Recalled for Roof Hatch Handle Defect

    Transportation Collaborative is recalling 2019-2020 TransTech school buses because the roof hatch handle may break, preventing emergency exit.

    Product
    TRANS TECH — TRANS TECH SST, CST
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V837000·2019-11-21

    GM Recalls 2020 Vehicles for Fuel Pump Pressure Regulator Defect

    General Motors is recalling 2020 Cadillac, Chevrolet, and GMC vehicles because a missing fuel pump pressure regulator may cause over-pressurization and fire risk.

    Product
    GMC — GMC, CADILLAC, CHEVROLET YUKON XL, ESCALADE ESV, SIERRA 1500, SUBURBAN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V838000·2019-11-21

    Navistar Recalls 2020 International HV Trucks for Brake Valve Defect

    Navistar is recalling 2020 International HV 6X4 vehicles because a non-Quick Release Modulator Valve may increase brake release time, raising the risk of brake or tire fires.

    Product
    INTERNATIONAL — INTERNATIONAL HV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·19V841000·2019-11-21

    Navistar Recalls International Trucks Due to Parking Brake Failure Risk

    Navistar is recalling specific International trucks because engaging the PTO switch can override the parking brake, causing unintended movement.

    Product
    INTERNATIONAL — INTERNATIONAL DURASTAR, WORKSTAR, HV, MV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·19V840000·2019-11-21

    Land Rover Recalls 2020 Range Rover Evoque for Headliner Plate Defect

    Jaguar Land Rover is recalling 2020 Range Rover Evoque vehicles because a metal plate on the headliner may detach during a crash, increasing injury risk.

    Product
    LAND ROVER — LAND ROVER RANGE ROVER EVOQUE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·19V839000·2019-11-21

    Ford Recalls 2019 Rangers Due to Rear Light Connector Issues

    Ford is recalling 2019 Ranger trucks because rear light connectors may be misaligned, causing lights to fail and increasing crash risk.

    Product
    FORD — FORD RANGER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V835000·2019-11-20

    Isuzu and Chevrolet Trucks Recalled for Rear Wheel Lug Nut Defect

    Isuzu is recalling certain 2017-2020 Isuzu and Chevrolet trucks because rear outer wheel lug nuts may not have been properly tightened, increasing crash risk.

    Product
    ISUZU — ISUZU, CHEVROLET NPR HD, NPR XD, NQR, NRR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·19V830000·2019-11-20

    Arcimoto Recalls 2019 FUV Motorcycles Due to Electrical Short Circuit Risk

    Arcimoto is recalling 25 units of the 2019 FUV motorcycle because a display board component may short circuit, potentially causing a sudden loss of power and increasing crash risk.

    Product
    ARCIMOTO — ARCIMOTO FUV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V833000·2019-11-19

    Arcimoto Recalls 2019 FUV Motorcycles Due to Inverter Software Defect

    Arcimoto is recalling 2019 FUV motorcycles because an inverter defect may cause unexpected battery shutdowns, increasing crash risk. Dealers will reprogram the inverter software free of charge.

    Product
    ARCIMOTO — ARCIMOTO FUV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V828000·2019-11-19

    Spartan Gladiator and Metrostar Recalled for Brake Control Line Defect

    Marion Body Works is recalling 2005-2020 Spartan Gladiator and Metrostar vehicles because air pressure control lines may not be protected, potentially causing unexpected brake application.

    Product
    SPARTAN — SPARTAN GLADIATOR, METROSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·19V829000·2019-11-19

    Freightliner Econic SD Recalled for Incorrect Axle Weight Rating Labels

    Daimler Trucks North America is recalling 2020 Freightliner Econic SD vehicles because certification labels contain incorrect gross axle weight rating information, which may lead to axle overloading.

    Product
    FREIGHTLINER — FREIGHTLINER ECONIC SD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·19V831000·2019-11-19

    Thomas Built Buses Recalling Saf-T-Liner HDX School Buses for Torque Converter Defect

    Daimler Trucks North America is recalling 2018-2020 Thomas Built Saf-T-Liner HDX school buses because loose torque converter fasteners may disable the vehicle, increasing injury risk during evacuation.

    Product
    THOMAS BUILT BUSES — THOMAS BUILT BUSES SAF-T-LINER HDX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V825000·2019-11-18

    Ducati Recalls 2018 Multistrada 1260 Motorcycles Due to Side Stand Defect

    Ducati is recalling 2018 Multistrada 1260 motorcycles because the side stand may be improperly welded. If the stand breaks, the motorcycle may fall over, increasing injury risk.

    Product
    DUCATI — DUCATI MULTISTRADA 1260
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V820000·2019-11-18

    Mercedes-Benz Recalls 2019 G-Class Vehicles for Door Wiring Defect

    Mercedes-Benz is recalling 2019 G 550 and G63 vehicles because improperly routed front door wiring may damage safety features, increasing crash injury risk.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ G 550, G63
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V822000·2019-11-18

    Mercedes-Benz Recalls 2019 GLC 300 for Power Steering Defect

    Mercedes-Benz is recalling 2019 GLC 300 vehicles because a failed electrical connection may cause loss of power steering assist, increasing crash risk.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ GLC 300
    Category
    Vehicle
    Distribution
    Distributed nationwide