The Recall Desk

State

Wisconsin product recalls

72,936 recalls have nationwide distribution and so reach Wisconsin. 8,408 additional recalls listed Wisconsin specifically in their distribution scope.

What the numbers show

Total
8,408
Critical
1,547
Severe
1,957
Most recent
2026-09-09

Of the 8,408 recalls naming Wisconsin we have scored against our rubric, 1,547 (18%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,957 (23%) are Severe.

These figures cover only the 8,408 recalls whose distribution notice names Wisconsin specifically. The 72,936 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

2901–2925 of 81344

  • HighFDA (Devices)·Z-1522-2026·2026-03-18

    Link Endo-Model plateau 15-0027/12 recalled over screw bushing fracture

    Waldemar Link is recalling Endo-Model Replacement Plateau item 15-0027/12 because the bushing on a plateau screw could detach from the screw shaft due to a longitudinal fracture.

    Product
    Endo-Model Replacement Plateau; Item Number: 15-0027/12;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1497-2026·2026-03-18

    IBA proton therapy system may not interrupt beam when gating fails

    Ion Beam Applications is recalling PROTEUS 235 proton therapy systems because a disabled interface means the safety system may not interrupt beam delivery if the external gating signal is lost.

    Product
    IBA Proton Therapy System - PROTEUS 235
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1563-2026·2026-03-18

    Medline Medcrest surgical gowns may delaminate prematurely after recommended laundering

    Medline is recalling Medcrest surgical gowns because the fabric may delaminate prematurely when the included laundering instructions are followed.

    Product
    Medline Medcrest Surgical Gowns: MDTGXC4J5XL DBQ-GOWN,SURG,XALT,L4, CRTCL CVR, GRN, 5 MDTGXC4JL DBD-GOWN,SURG,XALT,L4,CRTCL CVR,GREEN,L MDTGXC4JXL DBD-GOWN,SURG,XALT,L4,CRTCL CVR,GREEN,XL MDTGXC4JXXL DBD-GOWN,SURG,XALT,L4,CRTCL CVR,GREEN,XX MDTGXP4JL DBD-GOWN,SURG,XALT,L4,
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1543-2026·2026-03-18

    GEM Premier 5000 parts 00055445010 and 00055445011 may eject cartridges

    Instrumentation Laboratory is recalling GEM Premier 5000 parts 00055445010 and 00055445011 after confirmed complaints of Process Control Solution Not Detected errors during warm-up.

    Product
    GEM Premier 5000; Part No. 00055445010 & 00055445011.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1524-2026·2026-03-18

    GEM Premier 5000 PAK part 00055360004 may eject during warm-up

    Instrumentation Laboratory is recalling GEM Premier 5000 PAK part 00055360004 after confirmed complaints of Process Control Solution Not Detected errors during warm-up causing cartridge ejection.

    Product
    GEM Premier 5000 PAK, Part No. 00055360004.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1531-2026·2026-03-18

    GEM Premier 5000 PAK part 00055407511 may eject during warm-up

    Instrumentation Laboratory is recalling GEM Premier 5000 PAK part 00055407511 after confirmed complaints of Process Control Solution Not Detected errors during warm-up causing cartridge ejection.

    Product
    GEM Premier 5000 PAK; Part No. 00055407511.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1517-2026·2026-03-18

    Link Endo-Model plateau 15-8030/12 recalled over screw bushing fracture

    Waldemar Link is recalling Endo-Model Replacement Plateau item 15-8030/12 because the bushing on a plateau screw could detach from the screw shaft due to a longitudinal fracture.

    Product
    Endo-Model Replacement Plateau; Item Number: 15-8030/12;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1538-2026·2026-03-18

    GEM Premier 5000 part 00055430008 may eject cartridges during warm-up

    Instrumentation Laboratory is recalling GEM Premier 5000 part 00055430008 after confirmed complaints of Process Control Solution Not Detected errors during warm-up causing cartridge ejection.

    Product
    GEM Premier 5000; Part No. 00055430008.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1536-2026·2026-03-18

    GEM Premier 5000 part 00055415011 may eject cartridges during warm-up

    Instrumentation Laboratory is recalling GEM Premier 5000 part 00055415011 after confirmed complaints of Process Control Solution Not Detected errors during warm-up causing cartridge ejection.

    Product
    GEM Premier 5000; Part No: 00055415011.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1541-2026·2026-03-18

    GEM Premier 5000 part 00055445004 may eject cartridges during warm-up

    Instrumentation Laboratory is recalling GEM Premier 5000 part 00055445004 after confirmed complaints of Process Control Solution Not Detected errors during warm-up causing cartridge ejection.

    Product
    GEM Premier 5000; Part No. 00055445004.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1510-2026·2026-03-18

    Exactech Equinoxe core instrument kits may have handles missing cross-pins

    Exactech is recalling the Equinoxe Core Instrument Kit, model KIT-311X, because the impactor handle may be missing a cross-pin.

    Product
    Brand Name: Equinoxe Product Name: Equinoxe Core Instrument Kit Model/Catalog Number: KIT-311X
    Category
    Medical Device
    Distribution
    25 states
  • HighFDA (Devices)·Z-1530-2026·2026-03-18

    GEM Premier 5000 PAK part 00055407510 may eject during warm-up

    Instrumentation Laboratory is recalling GEM Premier 5000 PAK part 00055407510 after confirmed complaints of Process Control Solution Not Detected errors during warm-up causing cartridge ejection.

    Product
    GEM Premier 5000 PAK; Part No. 00055407510.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1552-2026·2026-03-18

    Beckman Coulter DxC 700 AU analyzer may stop analyzing after errors

    Beckman Coulter is recalling DxC 700 AU analyzers because leaving the calibration monitor open beyond 15 minutes can trigger database errors that stop the system analyzing.

    Product
    DxC 700 AU, REF: B86444, B86446
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1529-2026·2026-03-18

    GEM Premier 5000 PAK part 00055407508 may eject during warm-up

    Instrumentation Laboratory is recalling GEM Premier 5000 PAK part 00055407508 after confirmed complaints of Process Control Solution Not Detected errors during warm-up causing cartridge ejection.

    Product
    GEM Premier 5000 PAK; Part No. 00055407508.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1515-2026·2026-03-18

    Link Endo-Model plateau 15-2835/12 recalled over screw bushing fracture

    Waldemar Link is recalling Endo-Model Replacement Plateau item 15-2835/12 because the bushing on a plateau screw could detach from the screw shaft due to a longitudinal fracture.

    Product
    Endo-Model Replacement Plateau; Item Number: 15-2835/12;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1544-2026·2026-03-18

    Infant and child defibrillator electrodes recalled over pediatric electrode delamination

    Physio-Control is recalling Infant/Child Reduced Energy Defibrillator Electrodes, catalogue numbers 11101-000016 and 11101-000017, due to pediatric defibrillator electrode delamination.

    Product
    PHYSIO CONTROL INFANT/CHILD Reduced Energy Defibrillator Electrodes Catalog Numbers: 11101-000016 UDI-DI code: 00721902629013 Catalog Number: 11101-000017 UDI-DI code: 00721902682483 Infant/Child Reduced Energy Defibrillation Electrodes are pre gelled, self-adhesive, the
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·26V165000·2026-03-18

    Ford and Lincoln image module resets can disable rearview camera

    Ford is recalling certain 2022-2025 Lincoln Navigator, Nautilus, Aviator and Explorer vehicles because the Image Processing Module A may reset unexpectedly, losing the rearview camera image and driver assistance features.

    Product
    LINCOLN — LINCOLN, FORD AVIATOR, EXPLORER, NAUTILUS, NAVIGATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26V162000·2026-03-18

    Lexus NX, RX, and TX rearview camera software malfunction recall

    Toyota is recalling certain 2022–2026 Lexus NX, RX, and TX vehicles because the rearview camera image may fail to display when the vehicle is in reverse, reducing rear visibility and increasing crash risk.

    Product
    LEXUS — LEXUS NX, RX, TX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26V163000·2026-03-18

    2026 Land Rover Defender Third-Row Seat Belt Bracket Weld Defect

    Jaguar Land Rover North America is recalling certain 2026 Land Rover Defender vehicles because the third-row lower seat belt anchorage bracket may have an insufficient weld stud, potentially preventing proper restraint during a crash.

    Product
    LAND ROVER — LAND ROVER DEFENDER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1512-2026·2026-03-18

    Link Endo-Model plateau 15-0027/15 recalled over screw bushing fracture

    Waldemar Link is recalling Endo-Model Replacement Plateau item 15-0027/15 because the bushing on a plateau screw could detach from the screw shaft due to a longitudinal fracture.

    Product
    Endo-Model Replacement Plateau; Item Number: 15-0027/15;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1523-2026·2026-03-18

    Link Endo-Model plateau 15-0027/16 recalled over screw bushing fracture

    Waldemar Link is recalling Endo-Model Replacement Plateau item 15-0027/16 because the bushing on a plateau screw could detach from the screw shaft due to a longitudinal fracture.

    Product
    Endo-Model Replacement Plateau; Item Number: 15-0027/16;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1535-2026·2026-03-18

    GEM Premier 5000 part 00055415010 may eject cartridges during warm-up

    Instrumentation Laboratory is recalling GEM Premier 5000 part 00055415010 after confirmed complaints of Process Control Solution Not Detected errors during warm-up causing cartridge ejection.

    Product
    GEM Premier 5000; Part No. 00055415010.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1516-2026·2026-03-18

    Link Endo-Model plateau 15-2836/11 recalled over screw bushing fracture

    Waldemar Link is recalling Endo-Model Replacement Plateau item 15-2836/11 because the bushing on a plateau screw could detach from the screw shaft due to a longitudinal fracture.

    Product
    Endo-Model Replacement Plateau; Item Number: 15-2836/11;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1514-2026·2026-03-18

    Link Endo-Model SL connection component recalled over screw bushing fracture

    Waldemar Link is recalling Endo-Model SL Connection Component item 16-2840/07 because the bushing on a plateau screw could detach from the screw shaft due to a longitudinal fracture.

    Product
    Endo-Model SL Connection Component incl. PE-Plateau; Item Number: 16-2840/07;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1528-2026·2026-03-18

    GEM Premier 5000 PAK part 00055407504 may eject during warm-up

    Instrumentation Laboratory is recalling GEM Premier 5000 PAK part 00055407504 after confirmed complaints of Process Control Solution Not Detected errors during warm-up causing cartridge ejection.

    Product
    GEM Premier 5000 PAK; Part No. 00055407504.
    Category
    Medical Device
    Distribution
    Distributed nationwide