The Recall Desk

State

Washington product recalls

72,982 recalls have nationwide distribution and so reach Washington. 8,456 additional recalls listed Washington specifically in their distribution scope.

What the numbers show

Total
8,456
Critical
867
Severe
2,006
Most recent
2026-09-09

Of the 8,456 recalls naming Washington we have scored against our rubric, 867 (10%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 2,006 (24%) are Severe.

These figures cover only the 8,456 recalls whose distribution notice names Washington specifically. The 72,982 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

5851–5875 of 81438

  • HighFDA (Devices)·Z-2339-2025·2025-08-27

    Legacy electrosurgical generators recalled over system error triggering repeated device reboots

    The ESG-410 Legacy Electrosurgical Generator, model WA91307C, is recalled because it may display an E0662 System Error followed by a single automatic reboot or a continuous reboot loop. 434 units are affected.

    Product
    Electrosurgical, Cutting and Coagulation and Accessories. Electrosurgical Generator ESG-410. Model Number: WA91307C. The ESG-410 Electrosurgical Generator is an electrosurgical generator which utilizes monopolar and bipolar high frequency current and supports ultrasonic instr
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2338-2025·2025-08-27

    Electrosurgical generators recalled over system error causing reboots during use

    The ESG-410 Electrosurgical Generator is recalled because it may display an E0662 System Error followed by a single automatic reboot or a continuous reboot loop. 155 units are affected.

    Product
    Electrosurgical, Cutting and Coagulation and Accessories. Electrosurgical Generator ESG-410 Surgical Energy Platform (SEP). Model Number: WA91327U. The ESG-410 Electrosurgical Generator is an electrosurgical generator which utilizes monopolar and bipolar high frequency current
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·H-0505-2025·2025-08-27

    Ojasvita Chocomalt 200 g pouches recalled for undeclared soy lecithin

    Sri Sri Tattva Ojasvita Chocomalt, 7 oz / 200 g paper pouches, is recalled because it contains undeclared soy lecithin. 1,100 units are affected.

    Product
    Sri Sri Tattva, Ojasvita Chocomalt,7oz / 200g, Paper Pouch, 25 packages per case
    Category
    Food
    Distribution
    10 states
  • HighFDA (Devices)·Z-2329-2025·2025-08-27

    Endoscopy video processors recalled over hot light guide and thermal injury risk

    Pentax Medical EPK-i8020c video processors are recalled after reports of darkened images, smoke-like steam and a hot endoscope light guide that may cause thermal injury to the patient's mucous membrane. 144 units are affected.

    Product
    Pentax Medical Video Processor; Model Number: EPK-i8020c;
    Category
    Medical Device
    Distribution
    20 states
  • HighFDA (Devices)·Z-2340-2025·2025-08-27

    Deep brain stimulation burr hole kits recalled over retaining clip closing resistance

    Burr Hole Cover Kits used with the Vercise Deep Brain Stimulation System are recalled because resistance closing the retaining clip may cause procedural delay or lead migration requiring further surgery. 24,583 units are affected.

    Product
    Burr Hole Cover Kit, REF: M365DB4600C0; Burr Hole Cover Spares Kit, REF: M365DB4605C0. Components of Vercise Deep Stimulation System used with the Surgical Implant Manual
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2336-2025·2025-08-27

    Estrone diagnostic kits recalled over rare falsely high or low results

    Estrone RIA kits, catalog number DSL8700, are recalled because certain lots may rarely give falsely high or falsely low patient results. 279 units are affected.

    Product
    Estrone RIA Catalog Number DSL8700 UDI Code: 15099590211615 Estrone RIA is an in vitro diagnostic manual medical device used by healthcare professionals for the quantitative measurement of estrone in human serum and plasma.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0591-2025·2025-08-27

    Sodium bicarbonate injection vials recalled for lack of assurance of sterility

    Hospira 8.4% Sodium Bicarbonate Injection USP, 50 mEq/50 mL, lot LH2671, is recalled nationwide for lack of assurance of sterility. 15,750 vials are affected.

    Product
    SODIUM BICARBONATE — SODIUM BICARBONATE (SODIUM BICARBONATE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2331-2025·2025-08-27

    Bayonet injection needles recalled after showing elevated cytotoxicity in testing

    Bayonet Luer-Lock injection needles, models 50-353-23 and 50-345-23, are recalled because affected product showed elevated cytotoxicity values, which may present a risk of intolerance or allergic reaction.

    Product
    Injection needle, bayonet, Luer-Lock, 1. Model no. 50-353-23, working length 25 cm, total length 31cm, nonsterile; 2. Model no. 50-345-23, working length 24 cm, total length 31 cm, non-sterile
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0590-2025·2025-08-27

    Epinephrine injection vials recalled for lack of assurance of sterility

    Hospira Epinephrine Injection USP, 1 mg/10 mL, lots LY3681, LY4360 and LY4416, is recalled nationwide for lack of assurance of sterility. 49,620 vials are affected.

    Product
    Vial Label: Epinephrine Injection, USP, 1mg/10mL (0.1 mg/mL), Rx only, Distributed by Hospira, Inc., Lake Forest, IL 60045, USA. NDC 0409-4933-05. Case: NDC 0409-4933-10.
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0595-2025·2025-08-27

    Tavaborole topical solution recalled after discoloration found in one lot

    Tavaborole Topical Solution 5%, 10 mL bottles from lot T401968, distributed by Viona Pharmaceuticals, is recalled because of discoloration. 3,960 bottles are affected.

    Product
    TAVABOROLE — TAVABOROLE (TAVABOROLE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2337-2025·2025-08-27

    Strep A test kits recalled after shipment to unlicensed purchasing customers

    Clearview Strep A Exact II Dipstick Respiratory Kits are recalled because a classification error in the inventory system sent devices to customers without the required license to buy them. 5 kits are affected.

    Product
    Clearview Strep A Exact II Dipstick Respiratory Kit, CLIA Waived. Catalog Number: 4581225020
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2335-2025·2025-08-27

    Calcium test slides recalled after calibration failures delayed patient results

    VITROS Chemistry Products Ca Slides, catalog number 145 0261, generations 67 and above, are recalled because calibration failures on VITROS XT systems delay calcium test results. 174,215 units are affected.

    Product
    VITROS Chemistry Products Ca Slides; Catalog Number: 145 0261;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2330-2025·2025-08-27

    Suture retention devices recalled with no reason stated in FDA record

    DRS Vascular is recalling 264 Q-Stop Suture Retention Devices. The FDA enforcement record for this action carries a placeholder in place of a stated reason for the recall.

    Product
    Brand Name: Q-Stop Product Name: Suture Retention Device Model/Catalog Number: QS Software Version: N/A Product Description: The DRS Vascular Q-Stop Suture Retention Appliance is a sterile, single-use, lightweight device made of biocompatible materials that can be easily installe
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Drugs)·D-0592-2025·2025-08-27

    Sensodyne Pronamel toothpaste recalled after tube and carton labels were mixed up

    Sensodyne Pronamel Active Shield toothpaste is recalled for a label mix-up: the outer carton reads Fresh Mint while the tube reads Cool Mint/Whitening. The toothpaste inside is Fresh Mint, as the carton states.

    Product
    Sensodyne PRONAMEL (Potassium nitrate 5%, Sodium fluoride 0.25%) Active SHIELD Toothpaste for Sensitive Teeth, Fresh Mint, Net WT 3.4OZ (96.4g) Tube, 6 tubes x 2 inners, per case, Distributed by GSK Consumer Healthcare, Warren, NJ 07059. UPC 3 10158 35691 2
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V555000·2025-08-26

    Polestar 3 front bumper may be missing bolts and detach

    Polestar is recalling certain 2025 Polestar 3 vehicles because the hood wing front bumper may be missing bolts, allowing the bumper to detach and become a road hazard.

    Product
    POLESTAR — POLESTAR POLESTAR 3
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V550000·2025-08-26

    Forest River Riverstone hydraulic brake lines can fail and leak

    Forest River is recalling certain 2018-2026 Riverstone fifth wheel trailers because the steel hydraulic brake lines may fail and leak brake fluid, causing a loss of brake function.

    Product
    FOREST RIVER — FOREST RIVER RIVERSTONE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V554000·2025-08-26

    Tiffin Recalls 2025 GT1 Vans Due to Short Rear Seat Belts

    Tiffin Motorhomes is recalling 2025 GT1 Touring vans because rear seat belt buckles may be too short to fasten, increasing injury risk in a crash.

    Product
    TIFFIN — TIFFIN GT1
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V552000·2025-08-26

    Ram ProMaster and Dodge Journey rearview cameras may not display properly

    Chrysler is recalling certain 2019-2021 Ram ProMaster and 2019-2020 Dodge Journey vehicles because cracks in the microprocessor may stop the rearview camera image displaying properly.

    Product
    DODGE — DODGE, RAM JOURNEY, PROMASTER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25E052000·2025-08-26

    Chrysler Recalls Mopar Rearview Camera Modules Due to Image Display Issues

    Chrysler is recalling specific Mopar rearview camera modules because cracks in the microprocessor may prevent the image from displaying properly, increasing crash risk.

    Product
    BACK OVER PREVENTION: SENSING SYSTEM: CAMERA recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V548000·2025-08-25

    Kia K4 and Sorento connecting rod bolts may be improperly tightened

    Kia is recalling certain 2025 K4 and Sorento vehicles because the connecting rod bolts in the engine may have been improperly tightened, which can cause a loss of drive power.

    Product
    KIA — KIA K4, SORENTO
    Category
    Vehicle
    Distribution
    Distributed nationwide