The Recall Desk

State

US Virgin Islands product recalls

72,982 recalls have nationwide distribution and so reach US Virgin Islands. 177 additional recalls listed US Virgin Islands specifically in their distribution scope.

What the numbers show

Total
177
Critical
12
Severe
30
Most recent
2026-09-09

Of the 177 recalls naming US Virgin Islands we have scored against our rubric, 12 (7%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 30 (17%) are Severe.

These figures cover only the 177 recalls whose distribution notice names US Virgin Islands specifically. The 72,982 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

7301–7325 of 73159

  • HighCPSC·25177·2025-03-13

    BMC recalls Kaius 01 bicycles and framesets for fork separation hazard

    BMC recalled about 1,300 Kaius 01 bicycles because the fork steerer tube can crack and separate during use, posing a fall hazard. No injuries reported; consumers should stop using them and contact dealers for free fork replacement.

    Product
    BMC-branded Kaius 01 bicycles and framesets
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1244-2025·2025-03-12

    Rotarex Atherectomy Catheter Recalled for Helix Fracture Risk

    Bard is recalling Rotarex Atherectomy System catheters due to potential helix fracture or breakage that could cause vessel injury and severe bleeding. Updated instructions are being distributed to clarify procedural steps to reduce this risk.

    Product
    Rotarex Atherectomy System and Instructions for Use, BD SET Rotarex: S 6 F x 110 cm, REF: 80236; S 6 F x 135 cm, REF: 80237; S 8 F x 85 cm, REF: 80238; S 8 F x 110 cm, REF: 80239
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1257-2025·2025-03-12

    Insulin pump recall: Medtronic Paradigm models malfunction during airplane flight

    Medtronic MiniMed's Paradigm insulin pumps can malfunction during airplane flight due to air pressure changes, potentially causing dangerously high or low blood sugar levels that could be fatal.

    Product
    Paradigm insulin pump, REF: MMT-754
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V152000·2025-03-12

    Shyft Recalls 2025 Utilimaster Upfit Vehicles for Loose Seat Bolts

    Shyft Group is recalling 2025 Utilimaster Upfit vehicles because passenger jump seat mounting bolts may not be properly tightened, increasing injury risk in a crash.

    Product
    UTILIMASTER — UTILIMASTER UPFIT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V046000·2025-03-12

    Freightliner Recalls eCascadia and eM2 Trucks for Power Loss Risk

    Daimler Trucks North America is recalling 2020-2026 Freightliner eCascadia and eM2 trucks because a faulty power module may cause a loss of drive power, increasing crash risk.

    Product
    FREIGHTLINER — FREIGHTLINER E-CASCADIA, EM2
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1245-2025·2025-03-12

    Medtronic Pipeline Vantage Embolization Device Recall for Structural Deformation Risk

    Medtronic is recalling approximately 18,245 unused Pipeline Vantage embolization devices due to incomplete wall apposition and braid deformation that may lead to thrombosis and serious adverse events.

    Product
    Medtronic Pipeline Vantage Embolization Device with Shield Technology, REF: PED3-027-350-12, PED3-027-350-14, PED3-027-350-16, PED3-027-350-20, PED3-027-350-25, PED3-027-400-12, PED3-027-400-14, PED3-027-400-16, PED3-027-400-18, PED3-027-400-20, PED3-027-400-25, PED3-027-400-30,
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-0606-2025·2025-03-12

    Amazon Fresh Jumbo Sugar Cookies recalled for undeclared egg allergen

    Amazon Retail LLC is recalling Amazon Fresh Jumbo Sugar Cookies nationwide due to undeclared egg, a major allergen. Consumers with egg allergies should not consume the affected cookies.

    Product
    ASIN B084PZ7K98, Amazon Fresh Jumbo Sugar Cookie, 27 oz (12 count), product is baked and packaged in flexible plastic bag. 4-day shelf life. UPC 465712007998. ASIN B084PX9V31, Amazon Fresh Jumbo Sugar Cookie, 2.3 oz (1 count), product is baked and sold from open pastry tray in s
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-0607-2025·2025-03-12

    Frozen Sugar Cookie Dough Recalled for Undeclared Egg Allergen

    Amazon Fresh Bake at Home Jumbo Sugar Cookie dough is being recalled due to undeclared egg. Consumers with egg allergies should not consume this product.

    Product
    ASIN B0CY2RDW5T, Amazon Fresh brand, Bake at Home Jumbo Sugar Cookie 30oz, product is frozen dough, and packaged in flexible plastic bag. UPC 446472006995.
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1253-2025·2025-03-12

    Baxter Sigma Spectrum Infusion System Recalled for Missing Mounting Screws

    Baxter Healthcare is recalling 66 units of Sigma Spectrum Infusion System (V6) due to potential missing motor mounting screws that may have occurred during servicing. Missing screws could affect the device's operation.

    Product
    Baxter Sigma Spectrum Infusion System (V6 Platform), Product Code 35700BAX
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1254-2025·2025-03-12

    Baxter Spectrum IQ Infusion System may have missing motor mounting screws

    Baxter Spectrum IQ Infusion Systems may lack motor mounting screws due to a servicing defect. The FDA Class I recall affects 323 units distributed nationwide.

    Product
    Baxter Spectrum IQ Infusion System with Dose IQ Safety Software, Product Code 3570009
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V154000·2025-03-12

    BMW X3 rear brake hoses may leak and disable rear braking

    BMW is recalling certain 2025 X3 30 xDrive and X3 M50 xDrive vehicles because the rear brake hoses may leak, causing a loss of rear brake function, ABS and stability control.

    Product
    BMW — BMW X3
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1263-2025·2025-03-12

    Insulin Pump Recalled for Abnormal Delivery During Flight Pressure Changes

    Medtronic MiniMed 720G insulin pumps may malfunction during airplane travel due to air pressure changes, causing abnormal insulin doses that can lead to severe low or high blood sugar emergencies.

    Product
    MiniMed insulin pump, REF: 720G (MMT-1809, MMT-1810, MMT-1859, MMT-1860, MMT-1867)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1246-2025·2025-03-12

    Medtronic Pipeline Vantage device recall: deformation may cause blood clots

    The Pipeline Vantage Embolization Device may malfunction, with the braid deforming or not positioning correctly, potentially causing blood clots. Approximately 7,820 units are affected worldwide.

    Product
    Medtronic Pipeline Vantage Embolization Device with Shield Technology, REF: PED3-021-350-16, PED3-021-250-14, PED3-021-350-20, PED3-021-250-20, PED3-021-300-16, PED3-021-300-20, PED3-021-275-12, PED3-021-275-16, PED3-021-325-12, PED3-021-325-14, PED3-021-325-16, PED3-021-325-20,
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1259-2025·2025-03-12

    MiniMed Insulin Pumps Recalled for Abnormal Insulin Delivery During Flight

    MiniMed insulin pumps may deliver abnormal insulin doses during aircraft takeoff and landing due to air pressure changes, risking severe blood sugar fluctuations, seizures, and potentially fatal complications.

    Product
    MiniMed insulin pump, REF: 630G (MMT-1714, MMT-1715, MMT-1754, MMT-1755)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1266-2025·2025-03-12

    Medtronic MiniMed insulin pumps may deliver abnormal insulin doses during flight

    Medtronic MiniMed insulin pumps may deliver abnormal doses of insulin during airplane takeoff or landing due to air pressure changes. This can result in severe hypoglycemia or hyperglycemia, with potential for seizure, coma, or death.

    Product
    MiniMed insulin pump, REF: 780G (MMT-1884, MMT-1885, MMT-1886, MMT-1894, MMT-1895, MMT-1896)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1268-2025·2025-03-12

    Heat Moisture Exchanger Connector Occlusion May Impair Ventilation

    Kung Shin Plastics' CircuitGuard ThermoFlo Filter may have plastic obstructing the machine-side connector, preventing proper ventilation bag operation and risking oxygen deprivation during manual ventilation.

    Product
    CircuitGuard ThermoFlo Filter -Combined Heat and Moisture Exchanger, Bacterial Viral Filter w O2 Port and Elbow (Model/Catalogue number: SK200CPE / 6126)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·25V155000·2025-03-12

    Land Rover Recalls 2025 Range Rovers for Seat Belt Defect

    Jaguar Land Rover is recalling 2025 Range Rover and Range Rover Sport vehicles because the second-row center seat belt buckle may not latch correctly.

    Product
    LAND ROVER — LAND ROVER RANGE ROVER, RANGE ROVER SPORT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1262-2025·2025-03-12

    Medtronic MiniMed insulin pump recalled for abnormal delivery during air pressure changes

    Medtronic MiniMed insulin pumps may deliver insulin abnormally during airplane take-off or landing due to air pressure changes, risking severe low or high blood sugar emergencies.

    Product
    MiniMed insulin pump, REF: 700G (MMT-1801, MMT-1805, MMT-1850, MMT-1851)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1258-2025·2025-03-12

    MiniMed Insulin Pumps Recalled for Abnormal Delivery During Air Travel

    Medtronic recalled MiniMed insulin pumps due to abnormal delivery caused by air pressure changes during airplane flights. The defect can cause severe hypoglycemia or hyperglycemia, potentially leading to seizure, coma, or death.

    Product
    MiniMed insulin pump, REF: 620G (MMT-1750)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0254-2025·2025-03-12

    Morphine Sulfate Oral Syringes Recalled for Defective Delivery System Leakage

    Safecor Health is recalling Morphine Sulfate 5 mg oral syringes nationwide due to leakage in the delivery system following repackaging. No illnesses have been reported.

    Product
    Morphine Sulfate 5 mg per 0.25 mL Oral Syringe, Delivers: 0.25 mL, Oral Solution, Rx Only, Mfg by: Hikma, Pkg by: Safecor Health, LLC, Columbus, OH 43204, NDC: a) 00406800312, b) 00406800330, c) 00054051750.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1265-2025·2025-03-12

    MiniMed Insulin Pump May Malfunction at High Altitude During Flight

    Medtronic MiniMed insulin pumps may deliver abnormal insulin doses during airplane takeoff or landing due to air pressure changes, potentially causing severe low or high blood sugar.

    Product
    MiniMed insulin pump, REF: 770G (MMT-1880, MMT-1881, MMT-1882, MMT-1890, MMT-1891, MMT-1892)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1270-2025·2025-03-12

    Philips BGM 4 Blood Glucose Meter Battery Expansion Risk Recall

    Telcare recalls 34,764 Philips BGM 4 blood glucose meters (Model TM0009) nationwide due to battery expansion and swelling. The battery may cause the back cover to separate or, in worst-case scenarios, explode. No injuries reported to date.

    Product
    Philips Connected Blood Glucose Meter, BGM 4; Model Number: TM0009;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1293-2025·2025-03-12

    Alcon Custom Pak surgical packs mislabeled as latex-free despite containing latex

    Alcon surgical procedure packs contain latex but are labeled as latex-free, creating risk of allergic reaction for patients with latex sensitivity. The company is recalling 2,511 affected units.

    Product
    Alcon Custom Pak with Non-Latex Symbol, Pak: 12771-18, 18050-10, 18252-17, 12698-09, 15632-10, 3141-45, 12630-07, 18925-05, 19265-05, 13894-16, 17550-08, 12236-18, 11854-15, 8043-29, 12466-17, 15599-17, 14764-09, 13194-16, 17069-09
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1256-2025·2025-03-12

    Medtronic Paradigm insulin pump recall for abnormal delivery during flight

    Medtronic MiniMed Paradigm insulin pumps may deliver incorrect insulin doses during airplane takeoff or landing due to air pressure changes. This can cause severe high or low blood sugar requiring immediate medical attention.

    Product
    Paradigm insulin pump, REF: MMT-522, MMT-523, MMT-551, MMT-722, MMT-723, MMT-751
    Category
    Medical Device
    Distribution
    Distributed nationwide