The Recall Desk

State

US Virgin Islands product recalls

73,738 recalls have nationwide distribution and so reach US Virgin Islands. 178 additional recalls listed US Virgin Islands specifically in their distribution scope.

What the numbers show

Total
178
Critical
12
Severe
39
Most recent
2026-10-21

Of the 178 recalls naming US Virgin Islands we have scored against our rubric, 12 (7%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 39 (22%) are Severe.

These figures cover only the 178 recalls whose distribution notice names US Virgin Islands specifically. The 73,738 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

38401–38425 of 73916

  • SevereFDA (Devices)·Z-1826-2018·2018-05-23

    Medtronic Endo GIA Universal Staplers Recalled for Missing Sled Component

    Medtronic is recalling 171,271 Endo GIA Universal and Universal XL staplers worldwide due to a missing sled component that may cause staple line failure, bleeding, or leakage.

    Product
    (1) BOX 01KBAR006116V PROC BYPASS 01KBAR0061(Item Code 01KBAR006116V PROC BYPAS) (2) BOX 1073076GASB0 BBR STVEIT GASTRIC B (Item Code BOX1073076GASB0) (3) BOX BOX1073076GASB0 BBR STVEIT GASTRIC B (Item Code BOX1073076GASB0 BBR STVEIT GASTRIC B) Product Usage…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1823-2018·2018-05-23

    Medtronic Endo GIA Vascular Reloads Recalled for Missing Sled Component

    Medtronic is recalling specific Endo GIA vascular reloads because a missing sled component may prevent staple formation, potentially causing bleeding or leakage.

    Product
    Endo GIA" 45mm Gray Curved Tip Articulating Vascular Reload with Tri-Staple" Technology( Item Code EGIA45CTAV) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1830-2018·2018-05-23

    COVIDIEN Medtronic Recalls Endo GIA Staplers for Missing Sled Component

    COVIDIEN Medtronic is recalling approximately 171,271 Endo GIA universal staplers because a missing sled component may prevent proper staple deployment. This defect can lead to bleeding or leakage of luminal contents during surgery.

    Product
    (1)BOX HEMIGX1 ZESTAW DO HEMICOLECTOMII (Item Number HEMIGX1 ZESTAW DO HEMICOLECTOMII) (2) BOX LAPPH ZASTAW DO PRAWEJ HEMIKOLEKTOMI (item number: LAPPH ZASTAW DO PRAWEJ HEMIKOLEKTOMI Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1852-2018·2018-05-23

    Medtronic Endo GIA Staplers Recalled for Missing Sled Component

    Medtronic is recalling Endo GIA staplers because a missing sled component may prevent staple formation, leading to bleeding or leakage.

    Product
    BOX PST03533 KIT APP STAPLER Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the staples is determined by…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1816-2018·2018-05-23

    COVIDIEN Recalls Endo GIA Stapler Loading Units Due to Missing Sled Component

    COVIDIEN MEDTRONIC is recalling 171,271 Endo GIA Universal Articulating Loading Units because a missing sled component may prevent proper staple deployment, risking bleeding or leakage during surgery.

    Product
    Endo GIA" Auto Suture" Universal Articulating Loading Unit 30mm - 3.5mm ( Item Code 030452) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1824-2018·2018-05-23

    Medtronic Recalls Endo GIA Stapler Kits Due to Missing Sled Component

    Medtronic is recalling 171,271 Endo GIA stapler kits worldwide because a missing sled component may prevent staple formation, leading to bleeding or leakage.

    Product
    Covidien" Best Practices" Procedure Kits containing Auto Suture" Endo GIA" Devices Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1814-2018·2018-05-23

    Medtronic Recalls Endo GIA Stapler Loading Units Due to Missing Sled Component

    Medtronic is recalling 171,271 Endo GIA Auto Suture Universal Articulating Loading Units because a missing sled component may prevent staple formation, risking bleeding or leakage.

    Product
    Endo GIA" Auto Suture" Universal Articulating Loading Unit 30mm- 2.0mm ( Item Code 030450) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1847-2018·2018-05-23

    Medtronic Endo GIA Universal Staplers Recalled for Missing Sled Component

    Medtronic is recalling 169,775 Endo GIA Universal and Universal XL staplers worldwide and in the US because a missing sled component may prevent staple formation, risking bleeding or leakage.

    Product
    (1) BOX LAPZD ZESTAW DO SG (2) BOX LAPISG1 ZESTAW DO SG (3) BOX LAPISGW ZESTAW DO SG Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1843-2018·2018-05-23

    Medtronic Recalls Bariatric Surgical Kits Due to Missing Staple Sled Component

    Medtronic is recalling 169,775 bariatric surgical kits worldwide because a missing sled component may prevent staple formation, risking bleeding or leakage.

    Product
    (1)LAPBARLECZNA ZESTAW BARIATRYCZNY LECZNA (2) KITBAR021- BARIATRIC KIT X1 Item Code:KITBAR021- BARIATRIC KIT X0 (3)BOX SGGLOGX1 ZESTAW DO BARIATRII Item Code: SGGLOGX1 ZESTAW DO BARIATRII (4)BOX SGGLOGX1 ZESTAW DO BARIATRII Item Coder:SGGLOGX1 ZESTAW DO…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1840-2018·2018-05-23

    Medtronic Endo GIA Universal Staplers Recalled for Missing Sled Component

    Medtronic is recalling Endo GIA Universal and Universal XL staplers because a missing sled component may prevent staple formation, leading to bleeding or leakage.

    Product
    (1) BOX KITDE0143 BYPASS BOX (Item Number: KITDE0143, KITDE0143 BYPASS BOX) (2) BOX KITDE0154 BYPASS KH NORDWEST (Item Number: KITDE0154, KITDE0154 BYPASS KH NORDWEST Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1865-2018·2018-05-23

    Medtronic Endo GIA Staplers Recalled for Missing Sled Component

    Medtronic is recalling Endo GIA staplers because a missing sled component may prevent staple formation, potentially causing bleeding or leakage.

    Product
    BOX VMIN ZESTAW DO VATS PODSTAWOWY Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the staples is…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1825-2018·2018-05-23

    Medtronic Endo GIA Universal Staplers Recalled for Missing Sled Component

    Medtronic is recalling Endo GIA Universal staplers because a missing sled component may prevent staple formation, leading to bleeding or leakage.

    Product
    BOX KIT1095V KIT OBESITAS (Item Code KIT1095V) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the staples…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1821-2018·2018-05-23

    Medtronic Recalls Endo GIA Stapler Reloads Due to Missing Sled Component

    Medtronic is recalling 171,271 Endo GIA 30mm stapler reloads because a missing sled component may prevent staple formation, potentially causing bleeding or leakage.

    Product
    Endo GIA" 30mm Gray Curved Tip Articulating Vascular Reload with Tri-Staple" Technology( Item Code EGIA30CTAV) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1859-2018·2018-05-23

    Medtronic Endo GIA Stapler Sleeves Recalled for Missing Sled Component

    Medtronic is recalling 169,775 Endo GIA stapler sleeves worldwide due to a missing sled component that may prevent staple formation, risking bleeding or leakage.

    Product
    (1)BOX SLEEVEGK3 (2) BOX SLEEVEGK4 SLEEVE GASTRECTOMY (3)BOX SLEEVEJAWI SLEEVE GASTRECTOMY BOX (4) SSLEEVE ZEST DO SLEEVE GASTREKTOMIIX1 Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1817-2018·2018-05-23

    Medtronic Endo GIA Stapler Loading Units Recalled for Missing Sled Component

    Medtronic is recalling 171,271 Endo GIA Auto Suture Universal Articulating Loading Units because a missing sled component may prevent staple formation, risking bleeding or leakage.

    Product
    Endo GIA" Auto Suture" Universal Articulating Loading Unit 45mm - 2.5mm( Item Code 030454) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1828-2018·2018-05-23

    Medtronic Endo GIA Universal Staplers Recalled for Missing Sled Component

    Medtronic is recalling 171,271 Endo GIA Universal staplers because a missing sled component may prevent staple formation, risking bleeding or leakage.

    Product
    BOX1073076GASB1 BBR GASTRIC BYPASS S(Item Code BOX1073076GASB1 BBR GASTRIC BYPASS S) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1866-2018·2018-05-23

    Medtronic Endo GIA Staplers Recalled for Missing Sled Component

    Medtronic is recalling Endo GIA universal staplers because a missing sled component may prevent staple formation, potentially causing bleeding or leakage.

    Product
    BOX VWR ZESTAW DO VATS KLIN Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the staples is determined by…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1820-2018·2018-05-23

    Medtronic Recalls Endo GIA Stapler Loading Units Due to Missing Sled

    Medtronic is recalling 171,271 Endo GIA Auto Suture Universal Articulating Loading Units because a missing sled component may prevent staple formation, leading to bleeding or leakage.

    Product
    Endo GIA" Auto Suture" Universal Articulating Loading Unit 60mm - 3.5mm ( Item Code 030458) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1822-2018·2018-05-23

    Medtronic Endo GIA Stapler Reloads Recalled for Missing Sled Component

    Medtronic is recalling Endo GIA 30mm stapler reloads because a missing sled component may cause staple failure, leading to bleeding or leakage.

    Product
    Endo GIA" 30mm Gray Curved Tip Articulating Vascular Reload with Tri-Staple" Technology( Item Code EGIA30AV) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1837-2018·2018-05-23

    Medtronic Endo GIA Universal Bypass Kits Recalled for Missing Sled Component

    Medtronic is recalling specific Endo GIA Universal Bypass Kits because a missing sled component may prevent staple formation, potentially causing bleeding or leakage.

    Product
    KIT-DE-0080 BYPASS KIT LOHNE X1( Item KIT-DE-0080) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1849-2018·2018-05-23

    Medtronic Recalls Bariatric Staplers Due to Missing Sled Component

    Medtronic is recalling specific bariatric stapler kits because a missing sled component may prevent staple formation, potentially causing bleeding or leakage.

    Product
    (1)BOX PST01199 BARIATRIC TRISTAPLE (Item Number: PST01199) (2) BOX PST03403 ALTERNATIVE APPENDIX KIT (Item Number: PST03403) (3) BOX PST03533 KIT APP STAPLER (Item Number: PST03403) Product Usage: The Endo GIA universal and…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1832-2018·2018-05-23

    COVIDIEN Medtronic Recalls Endo GIA Stapler Kits Due to Missing Sled

    COVIDIEN Medtronic is recalling Endo GIA universal stapler kits because a missing sled component may prevent proper staple deployment, risking bleeding or leakage.

    Product
    BOX KIT00713 KIT BY PASS Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the staples is determined by the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0840-2018·2018-05-23

    Apotex Recalls Subpotent Piperacillin and Tazobactam Injection Vials

    Apotex Inc. is recalling specific lots of Piperacillin and Tazobactam for Injection due to high impurity levels that decreased the drug's potency.

    Product
    Piperacillin and Tazobactam for Injection, USP 4.5 gram/vial* 10-count Single Use Vials per carton, Rx only, Mfg. by: Hospira Healthcare India Pvt. Ltd. Irungattukottai-602 105, India Mfg. for: Apotex Corp. Weston, FL 33326. NDC 60505-0688-4
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1839-2018·2018-05-23

    Medtronic Recalls Bypass Kits Due to Missing Stapler Component

    Medtronic is recalling 171,271 Endo GIA Bypass Kits because a missing sled component may prevent staple formation, potentially causing bleeding or leakage.

    Product
    BOX KITDE0108 BYPASS KIT LUEBECK ( KITDE0108) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the staples…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1831-2018·2018-05-23

    Medtronic Endo GIA Staplers Recalled for Missing Sled Component

    Medtronic is recalling Endo GIA universal staplers because a missing sled component may prevent staple formation, potentially causing bleeding or leakage.

    Product
    KIT00486R OBESIDAD D. WORWARLD 2 X1 (Item Number KIT00486R) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered…
    Category
    Medical Device
    Distribution
    Distributed nationwide