The Recall Desk

State

Texas product recalls

72,966 recalls have nationwide distribution and so reach Texas. 12,390 additional recalls listed Texas specifically in their distribution scope.

What the numbers show

Total
12,390
Critical
1,705
Severe
2,407
Most recent
2026-09-16

Of the 12,390 recalls naming Texas we have scored against our rubric, 1,705 (14%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 2,407 (19%) are Severe.

These figures cover only the 12,390 recalls whose distribution notice names Texas specifically. The 72,966 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

5201–5225 of 85356

  • CriticalFDA (Devices)·Z-0053-2026·2025-10-22

    BF-H190 bronchovideoscopes recalled for updated laser and coagulation use instructions

    Olympus is recalling EVIS EXERA III Bronchovideoscope BF-H190 units for instructions-for-use updates on safe use with laser, argon plasma coagulation and high-frequency therapy equipment.

    Product
    EVIS EXERA III BRONCHOVIDEOSCOPE OLYMPUS BF-H190
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0031-2026·2025-10-22

    Percussive ventilation valves recalled over leak risk in small patients

    Percussionaire is recalling 59,160 Phasitron 5 IPV in-line valves whose pressure relief seal may leak when used with a ventilator, and is warning against use in neonates and infants.

    Product
    Phasitron 5, IPV In-Line Valve, (Intrapulmonary Percussive Ventilation) REF: P5-TEE-20 (pack of 20)/ P5-TEE (individual) with In-Line Valve Sentec Instructions for Use
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Food)·H-0055-2026·2025-10-22

    Large white eggs in cartons recalled over potential Salmonella contamination

    Black Sheep Egg Company is recalling 23,400 dozen Free Range Grade AA Large White Eggs in 12-count cartons for potential Salmonella contamination.

    Product
    Free Range Grade AA Large White Eggs, 12ct Cartons, 15dz per box, Black Sheep Egg Company 400 S Memorial Drive Walnut Ridge AR 72476
    Category
    Food
    Distribution
    6 states
  • SevereNHTSA·25V719000·2025-10-22

    Isuzu and Chevrolet axle stabilizer bracket bolts can crack and break

    Isuzu is recalling certain 2018-2026 Isuzu FVR and FTR and Chevrolet 6500XD and 7500XD vehicles because the axle stabilizer bracket bolts may crack and break, letting the bracket detach.

    Product
    CHEVROLET — CHEVROLET, ISUZU 6500XD, 7500XD, FTR, FVR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0169-2026·2025-10-22

    Monitor display cables recalled over inadequate shielding and electromagnetic interference

    Spacelabs Healthcare is recalling 16,898 DVI display cables because inadequate shielding may allow electromagnetic interference with other electronically sensitive medical devices in use.

    Product
    Brand Name: Branding is not applied to this product. Product Name: DVI display cables Model/Catalog Number: 012-0893-01 Software Version: N/A Product Description: 16 inch DVI-I to DVI-I male/male display cable. Component: Yes, the cable is an external display cable used with
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0194-2026·2025-10-22

    Three valve retractable collar sets recalled across many lots for leak potential

    Baxter is recalling 1,167,120 CLEARLINK System Continu-Flo solution sets with three luer activated valves and a retractable collar because the IV sets may leak.

    Product
    CLEARLINK SYSTEM CONTINU-FLO Solution Set, Non-Vented, three CLEARLINK Luer Activated Valves, Backcheck Valve, Retractable Collar, 10 drops/mL, 120-inch (3.0 meters), Product Code 2C8541
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0181-2026·2025-10-22

    Caesarean section packs recalled after being sterilized more than once

    American Contract Systems is recalling C-section convenience packs that were re-gassed after a sterilization nonconformance, without validation for multiple cycles.

    Product
    Medical convenience kits Item Number/Description FHCP08Y C SECTION PK HICS50I C-SECTION PACK HSCB90B C-SECTION BASIN PACK
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0186-2026·2025-10-22

    PICC and gastrostomy tube packs recalled after being sterilized more than once

    American Contract Systems is recalling PICC G-Tube convenience packs that were re-gassed after a sterilization nonconformance, without validation for multiple cycles.

    Product
    Medical convenience kits UDPG88W PICC G-TUBE PACK-230209
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·H-0058-2026·2025-10-22

    Aluminium cookware sets recalled for containing elevated levels of lead

    Goyal Group is recalling 293 sets of Silver Horse aluminium milk pans and mathar kadai cookware because they contain elevated levels of lead.

    Product
    1. SILVER HORSE - PURE ALUMINIUM MADE IN INDIA - ALUMINIUM MILK PAN 4 inches 2. SILVER HORSE - ALUMINIUM MATHAR KADAI - 26 inches
    Category
    Consumer Product
    Distribution
    13 states
  • HighFDA (Devices)·Z-0140-2026·2025-10-22

    CX preconnect pumps without InhibiZone recalled over inflation deflation issues

    Boston Scientific is recalling CX Preconnect with TENACIO Pump without InhibiZone because of the potential for inflation or deflation performance issues or difficulties.

    Product
    CX Preconnect with TENACIO Pump without InhibiZone; UPNs: (1) 72404486 (15CM IP), (2) 72404488 (21CM IP);
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0144-2026·2025-10-22

    LGX preconnect pumps recalled over inflation and deflation performance issues

    Boston Scientific is recalling 490 LGX Preconnect devices with TENACIO Pump and InhibiZone because of the potential for inflation or deflation performance issues or difficulties.

    Product
    LGX Preconnect with TENACIO Pump with InhibiZone; UPNs: (1) UPN: 72404450 (12CM PS IZ), (2) 72404451 (15CM PS IZ), (3) 72404452 (18CM PS IZ), (4) 72404453 (21CM PS IZ), (5) 72404455 (12CM IP IZ), (6) 72404456 (15CM IP IZ), (7) 72404457 (18CM IP IZ), (8) 72404458 (21CM IP IZ);
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0199-2026·2025-10-22

    Extension IV sets recalled from one lot because the sets may leak

    Baxter is recalling 16,416 CLEARLINK System straight-type extension sets from one lot because the IV sets may leak.

    Product
    CLEARLINK SYSTEM EXTENSION SET, Straight-Type Extension Set, Standard Bore, CLEARLINK Luer Activated Valve, Retractable Collar, 7.9-inch (20 centimeters), Product Code 2C8634
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·H-0134-2026·2025-10-22

    Baby food pouches recalled over potential lead contamination in four lots

    Sprout Organics is recalling 9,873 cases of its Sweet Potato, Apple & Spinach baby food for potential contamination with lead.

    Product
    6+ Months SPROUT ORGANICS Made With Organic Sweet Potato, Apple & Spinach NET WT. 3.5 OZ (99g) INGREDIENTS: ORGANIC SWEET POTATOES, ORGANIC APPLES, ORGANIC SPINACH, WATER, ORGANIC LEMON JUICE. Dist. by Sprout Foods, Inc. Montvale, NJ 07645 UPC: 818512011762
    Category
    Food
    Distribution
    34 states
  • HighFDA (Devices)·Z-0173-2026·2025-10-22

    Labor and delivery packs recalled after being sterilized more than once

    American Contract Systems is recalling labor, delivery and birthing room convenience kits that were re-gassed after a sterilization nonconformance, without validation for multiple cycles.

    Product
    Medical convenience kits Item number/ Product description AHLD15X LABOR DELIVERY PACK - 213387 AKDV96B VAGINAL DELIVERY AKDV96B VAGINAL DELIVERY EVBH28D BIRTHING ROOM PACK UPVD01K VAGINAL DELIVERY PACK
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0204-2026·2025-10-22

    Non-DEHP solution sets recalled from one lot because IV sets may leak

    Baxter is recalling 18,720 CLEARLINK System non-DEHP Continu-Flo solution sets from one lot because the IV sets may leak.

    Product
    CLEARLINK SYSTEM NON-DEHP CONTINU-FLO SOLN SET, 96" (2,4 m), Product Code: 2H8519
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0139-2026·2025-10-22

    TENACIO pumps without InhibiZone recalled over inflation and deflation issues

    Boston Scientific is recalling TENACIO Pump without InhibiZone, UPN 72404420, because of the potential for inflation or deflation performance issues or difficulties.

    Product
    TENACIO Pump without InhibiZone; UPN: 72404420;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·H-0042-2026·2025-10-22

    Frozen burrito bowl blend recalled because it may contain undeclared shrimp

    One Frozen is recalling 57,240 bags of Good and Gather Southwest-Style Burrito Bowl Blend because the product may contain undeclared shrimp.

    Product
    Good and Gather brand Southwest-Style Burrito Bowl Blend Processed in a facility that also handles shellfish, egg, fish, milk, sesame, soy, tree nut and wheat ingredients
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0133-2026·2025-10-22

    Powered ambulance cots recalled because fastening post hardware could loosen

    Ferno-Washington is recalling 138 Ferno Power X2 powered ambulance cots because the fastening post hardware could loosen, allowing the post to detach from the cot.

    Product
    FERNO POWER X2 POWERED AMBULANCE COT, Model/Catalog Number: 0015816; FOR USE IN GROUND TRANSPORTATION AMBULANCES.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0153-2026·2025-10-22

    Femoral head implants recalled over packaging that may compromise sterile barrier

    BioPro is recalling 147 femoral head implants over a potential packaging issue that could compromise the sterile barrier and present a risk of infection if implanted.

    Product
    BioPro Femoral Head Product ID/Description 14089 HEAD FEMORAL 28 SH LT 14090 HEAD FEMORAL 28 MD LT 14091 HEAD FEMORAL 28 LG LT 14094 HEAD FEMORAL 32 SH LT 14095 HEAD FEMORAL 32 MD LT 14096 HEAD FEMORAL 32 LG LT
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-0172-2026·2025-10-22

    General and laparotomy packs recalled after being sterilized more than once

    American Contract Systems is recalling general, chest, laparotomy and interventional radiology convenience packs that were re-gassed after a sterilization nonconformance.

    Product
    Medical convenience kits Item number/ Product description AKGN82E GENERAL AMCB08Y CHEST BREAST PACK ANBP10AC BASIC PACK - 205939 ANIR77AM INTERVENTIONAL RADIOLOGY PACK - 205953 CFLA39G LAPAROTOMY PACK CIBL33I BASIC LAP PACK EVMN24E MINOR ESC EVST48E STARTER FDTA11AA
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0197-2026·2025-10-22

    Forty four inch extension sets recalled because the IV sets may leak

    Baxter is recalling 15,552 CLEARLINK System 44-inch straight-type extension sets from one lot because the IV sets may leak.

    Product
    CLEARLINK SYSTEM EXTENSION SET, Straight-Type Extension Set, Standard Bore, CLEARLINK Luer Activated Valve, Retractable Collar, 44-inch (111 centimeters), Product code 2C8610
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0168-2026·2025-10-22

    Twelve foot display cables recalled over inadequate shielding and interference

    Spacelabs Healthcare is recalling 820 twelve-foot DVI display cables because inadequate shielding may allow electromagnetic interference with other electronically sensitive medical devices in use.

    Product
    Brand Name: Branding is not applied to this product. Product Name: DVI display cables Model/Catalog Number: 012-0895-12 Software Version: N/A Product Description: 12 foot DVI-I to DVI-I male/male display cable. Component: Yes, the cable is an external display cable used with
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0135-2026·2025-10-22

    Goniotomy instruments recalled over compromised sterile packaging integrity

    Iantrek is recalling 198 C-Rex UNO Microinterventional Goniotomy Instruments over the potential for compromised integrity of the sterile packaging.

    Product
    C-Rex UNO Microinterventional Goniotomy Instrument. Model Number: CRX-120. Product Description: The C-Rex UNO Microinterventional Goniotomy Instrument is a sterile single use disposable manual surgical instrument used in ophthalmic procedures for ab interno goniotomy and inne
    Category
    Medical Device
    Distribution
    Distributed nationwide