The Recall Desk

State

Puerto Rico product recalls

72,940 recalls have nationwide distribution and so reach Puerto Rico. 3,090 additional recalls listed Puerto Rico specifically in their distribution scope.

What the numbers show

Total
3,090
Critical
366
Severe
625
Most recent
2026-09-02

Of the 3,090 recalls naming Puerto Rico we have scored against our rubric, 366 (12%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 625 (20%) are Severe.

These figures cover only the 3,090 recalls whose distribution notice names Puerto Rico specifically. The 72,940 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

3926–3950 of 76030

  • SevereNHTSA·25V867000·2025-12-15

    Mack Trucks Recalls 2010-2016 Granite Trucks Due to Brake Imbalance Risk

    Mack Trucks is recalling 2010-2016 Granite trucks because incorrect parts from a previous repair may cause brake overheating, increasing the risk of tire blowouts or fires.

    Product
    MACK — MACK GRANITE (GU)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V866000·2025-12-12

    Ford Super Duty trucks recalled over rear axle shafts that may break

    Ford is recalling 6,819 model year 2026 Super Duty F-250 and F-350 vehicles because the right rear axle shaft may have been improperly heat-treated and may break.

    Product
    FORD — FORD F-250 SD, F-350 SD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V860000·2025-12-12

    Ford Recalls 2022-2025 E-Transit Vehicles Due to Axle Shaft Defect

    Ford is recalling 2022-2025 E-Transit vehicles because the left rear axle half shaft may disengage, causing loss of drive power or vehicle rollaway.

    Product
    FORD — FORD E-TRANSIT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereUSDA FSIS·038-2025·2025-12-12

    Suzanna's Kitchen Recalls Breaded Chicken for Undeclared Soy Allergen

    Suzanna's Kitchen is recalling fully cooked breaded chicken products because they contain soy, a known allergen, that is not declared on the label.

    Product
    Suzanna's Kitchen — Suzanna’s Kitchen Recalls Fully Cooked Breaded Chicken Products Due to Misbranding and an Undeclared Allergen
    Category
    Food
    Distribution
    Distributed nationwide
  • HighNHTSA·25V862000·2025-12-12

    Ford Recalls 2025-2026 Corsair and Escape for Seat Belt Defect

    Ford is recalling 2025-2026 Corsair and Escape vehicles because rear seat belt retractors may not be securely fastened, increasing injury risk in crashes.

    Product
    LINCOLN — LINCOLN, FORD CORSAIR, ESCAPE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V863000·2025-12-12

    Ford electric trucks and SUVs recalled over a park function failure

    Ford is recalling 272,645 F-150 Lightning, Mustang Mach-E and Maverick vehicles because the integrated park module may fail to lock into park when the driver shifts into park.

    Product
    FORD — FORD F-150 LIGHTNING BEV, MAVERICK, MUSTANG MACH E
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V865000·2025-12-12

    Mercedes-Benz wagons recalled over wiring harness routing near the front driveshaft

    Mercedes-Benz USA is recalling 117 AMG E 53 4MATIC+ Wagon vehicles because the transmission wiring harness may be routed too close to the front driveshaft, which can cause a loss of drive power.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ AMG E 53 4MATIC+ WAGON
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V858000·2025-12-11

    Honda Recalls 2025 CR-V Fuel Cell EVs for Fuel Cell Leak Risk

    Honda is recalling 2025 CR-V Fuel Cell EVs because coolant may leak into the fuel cell stack, causing an internal short circuit and loss of drive power.

    Product
    HONDA — HONDA CR-V FUEL CELL EV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereCPSC·26142·2025-12-11

    Garment steamers recalled after hot water leaks caused burn injuries

    About 2,840 VEVOR Garment Steamers are being recalled because they can leak or spit hot water. Reported cap failures resulted in two burn injuries, including a second-degree burn with permanent scarring.

    Product
    VEVOR Garment Steamers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V859000·2025-12-11

    Honda Recalls 2016-2020 Acura ILX for Brake Master Cylinder Defect

    Honda is recalling 2016-2020 Acura ILX vehicles because contaminated brake fluid may deform a seal, causing an internal leak and reduced brake function.

    Product
    ACURA — ACURA ILX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·26138·2025-12-11

    Electric bicycles recalled because chainring bolts can come loose

    About 700 model year 2026 Trek Domane+ and Checkpoint+ electric bicycles are being recalled because the chainring bolts can come loose, causing the chainring to separate from the bike.

    Product
    Model Year 2026 Trek-branded Domane+ ALR 5, Domane+ ALR 6 AXS, Checkpoint+ SL 6 and Checkpoint+ SL 7 Electric Bicycles
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·26141·2025-12-11

    Infant walkers recalled over fall and head entrapment hazards

    About 2,650 Uuoeebb infant walkers are being recalled because they can fit through a standard doorway and fail to stop at the edge of a step, and their leg openings can entrap a child's head.

    Product
    Uuoeebb Infant Walkers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·26148·2025-12-11

    Youth ATVs recalled for failing the mandatory ATV safety standard

    About 2,290 X-Pro Eagle and FRP Sahara 40cc youth ATVs are being recalled because their mechanical suspension fails safety requirements and the handlebars pose a laceration hazard.

    Product
    X-Pro Eagle 40cc Youth ATVs and FRP Sahara 40cc Youth ATVs
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·25E087000·2025-12-11

    Lippert Recalls Q'Straint QRT-Max Wheelchair Restraints Due to Locking Defect

    Lippert is recalling Q'Straint QRT-Max wheelchair restraints because the retractors may not lock, preventing proper securing of the wheelchair.

    Product
    EQUIPMENT ADAPTIVE/MOBILITY:WHEELCHAIR RESTRAINTS/SECUREMENT:LATCH/ANCHOR: recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·26146·2025-12-11

    Baby bath seats recalled because they are unstable and can tip over

    About 8,960 YCXXKJ baby bath seats are being recalled because they are unstable and can tip over while in use, posing a risk of serious injury or death due to drowning.

    Product
    YCXXKJ Baby Bath Seats
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·25V856000·2025-12-11

    GMC Canyon pickups recalled over air bag software that may deploy improperly

    General Motors is recalling 1,120 GMC Canyon AT4X AEV vehicles because incorrect sensing and diagnostic module software may cause a second stage passenger air bag deployment when only a first stage is intended.

    Product
    GMC — GMC CANYON
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0586-2026·2025-12-10

    Infusion pump administration sets recalled over incorrect assembly of one lot

    Fresenius Kabi USA is recalling 483 cases of Ivenix LVP Primary Administration Sets after incorrect assembly of a specific lot that the firm states could result in serious patient injury.

    Product
    IVENIX INFUSION SYSTEM, LVP Primary Administration Set, Dual-Inlet, Low-Sorbing, Needle-Free Port, Dual Y-Site (Qty 25). Large Volume Infusion Pump Administration Set.
    Category
    Medical Device
    Distribution
    Distributed nationwide