21301–21325 of 80919

  • SevereFDA (Food)·F-1411-2022·2022-07-13

    Built Bar Banana Cream Pie Puffs Protein Bars Recalled for Potential E. coli Contamination

    Built Brands LLC is recalling approximately 4,196 individual Banana Cream Pie Puffs Protein Bars sold nationwide due to potential Escherichia coli contamination.

    Product
    Built Bar, Banana Cream Pie Puffs Protein Bar, 1.41 oz. (40 g) net wt., packaged in individual wrapper, Built Brands, LLC, 600 E Quality Dr., American Fork, UT 84003. SKU 30000318. Product sold as part of a paperboard 12-count mixed box. Each box contains 4 affected bars. UPC 8…
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-1175-2022·2022-07-13

    CVS Health Magnesium Citrate Laxative Recalled for Bacterial Contamination

    CVS Health Magnesium Citrate SALINE LAXATIVE Oral Solution (1.745 g, Lemon Flavor, 10 FL OZ) is being recalled due to microbial contamination with Gluconacetobacter Liquefaciens. Approximately 98,958 bottles distributed nationwide are affected.

    Product
    CVS Health Magnesium Citrate SALINE LAXATIVE, Oral Solution, 1.745 g, Lemon Flavor, 10 FL OZ (296 mL), Distributed by: CVS Pharmacy, Inc., One CVS Drive, Woonsocket, RI 02895, UPC 0 50428 30594 2.
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1318-2022·2022-07-13

    Palindrome SI Chronic Dialysis Catheters Recalled for Hub Leaking Risk

    Covidien is recalling 2,462 units of Palindrome SI Chronic Catheters due to a potential leaking condition in the hub that may cause unanticipated fluid return during treatment.

    Product
    Palindrome SI Chronic Catheter, Sterile, Single Use, Rx Only. For acute and chronic hemodialysis, apheresis, and infusion.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1315-2022·2022-07-13

    Palindrome Precision Chronic Dialysis Catheters Risk Fluid Leakage Due to Hub Defect

    Covidien recalls 25,765 Palindrome Precision HSI Chronic Catheters due to a defect in the hub that may cause unintended fluid leakage during dialysis treatment.

    Product
    Palindrome Precision HSI Chronic Catheter, Sterile, Single Use, Rx Only. For acute and chronic hemodialysis, apheresis, and infusion.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1317-2022·2022-07-13

    Palindrome H Chronic Catheters Recalled for Potential Hub Leaking

    Palindrome H Chronic Catheters are being recalled due to a potential leaking condition in the catheter hub that may result in unanticipated fluid return during hemodialysis treatment. Affected units have been distributed worldwide.

    Product
    Palindrome H Chronic Catheter, Sterile, Single Use, Rx Only. For acute and chronic hemodialysis, apheresis, and infusion.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1316-2022·2022-07-13

    Palindrome Chronic Catheter recalled due to potential hub leakage

    Covidien is recalling Palindrome Chronic Catheters due to a potential leaking condition in the hub that may cause unexpected fluid return during use.

    Product
    Palindrome Chronic Catheter, Sterile, Single Use, Rx Only. For vascular access for acute and chronic hemodialysis, apheresis, and infusion.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V501000·2022-07-13

    2022 Toyota Tundra rear camera software defect increases crash risk

    The 2022 Toyota Tundra with Panoramic View Monitor may display front camera footage instead of rear camera when in reverse, reducing rear visibility and increasing crash risk. Toyota will reprogram the parking assist system free of charge.

    Product
    TOYOTA — TOYOTA TUNDRA HYBRID, TUNDRA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1313-2022·2022-07-13

    Palindrome Precision H Chronic Catheter Recalled for Potential Hub Leakage

    Covidien is recalling certain Palindrome Precision H Chronic Catheters because the hub may leak, causing unexpected fluid to flow back during use. This FDA Class I recall affects 26,675 units distributed globally.

    Product
    Palindrome Precision H Chronic Catheter, Sterile, Single Use, Rx Only. For vascular access for acute and chronic hemodialysis, apheresis, and infusion.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1320-2022·2022-07-13

    Dialysis Catheters Recalled for Potential Fluid Leakage from Hub Defect

    Covidien is recalling Mahurkar Chronic Carbothane dialysis catheters due to a potential leaking condition in the hub that may cause unanticipated fluid return during use. Approximately 132,443 units distributed worldwide are affected.

    Product
    Mahurkar Chronic Carbothane (Maxid) Catheter, Sterile, Single Use, Rx Only. For acute and chronic hemodialysis, apheresis, and infusion.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1403-2022·2022-07-13

    Organic Oregano Leaf Powder and Ground Oregano Recalled for Salmonella Contamination

    Pure Ground Ingredients has recalled specific lots of organic oregano leaf powder and ground oregano sold in Oregon, Wisconsin, Maryland, and Colorado due to potential Salmonella contamination.

    Product
    Pure Ground Ingredients Organic Oregano Leaf Powder Item#: OREO-PW Weight: 35 LBS/15.89 kgs Processed and Packaged at Pure Ground Ingredients 2535 Business Parkway Minden, NV 89423 Certified Organics By CCOF Organic Oregano Leaf Ground Item#: OREO-GR Weight: 35 LBS/15.89 kgs…
    Category
    Food
    Distribution
    4 states
  • SevereFDA (Devices)·Z-1314-2022·2022-07-13

    Palindrome Precision SI Chronic Catheters Recalled for Potential Hub Leaking

    Covidien recalls Palindrome Precision SI chronic dialysis catheters due to a potential leaking condition in the hub that may cause unanticipated fluid return during use.

    Product
    Palindrome Precision SI Chronic Catheter, Sterile, Single Use, Rx Only. For vascular access for acute and chronic hemodialysis, apheresis, and infusion.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1341-2022·2022-07-13

    Cardiac Troponin Diagnostic Test Recalled for Positive Bias in Plasma Samples

    Siemens Dimension CTNI cardiac troponin test is recalled for positive bias (falsely elevated readings) in Lithium Heparin plasma samples, which may lead to misdiagnosis of myocardial infarction.

    Product
    Dimension CTNI-In vitro diagnostic test intended to quantitively measure cardiac troponin-I levels in human serum and heparinized plasma to aid in the diagnosis of myocardial infarction. Siemens Material Number (SMN)/REF (Catalog Number): 10444905/RF421C
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1311-2022·2022-07-13

    NaturaLyte 2301 dialysate recalled for storage exposure and leaks

    Fresenius Medical Care recalled NaturaLyte 2301 dialysate in Texas and Louisiana after exposure to below-recommended storage temperatures. The exposure may cause packaging leaks, potentially leading to biological contamination and bloodstream infection risk.

    Product
    NaturaLyte 2301 2K 3.0 Ca 1 Mg Gal, Model No. 08-2301-3
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-1407-2022·2022-07-13

    Plant-Based Yogurt Recall for Potential Glass Contamination

    EAT REAL FOOD LLC is recalling Culina Plant Based Yogurt nationwide due to potential glass fragments in the product. Affected units were distributed to all states.

    Product
    Plant Based Yogurt Culina Plain & Simple Nt Wt 5 oz. (142 g) UPC 854724007087 packaged in glass container 12 jars per case
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1330-2022·2022-07-13

    Ossur Variflex Suba Junior prosthetic foot may crack under impact

    Ossur has recalled 410 Variflex Suba Junior prosthetic feet due to cracking and breaking under impact stress. The device is designed for children and adolescents worldwide.

    Product
    OSSUR VARIFLEX SUBA JUNIOR foot and ankle external prosthesis, sized for children and adolescents.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-1405-2022·2022-07-13

    Plant-Based Yogurt Recalled Due to Potential Glass Contamination

    EAT REAL FOOD LLC is recalling Culina Plant Based Blueberry Lavender Yogurt due to potential glass fragments. Affected lots were distributed nationwide with best-by dates in October and November 2022.

    Product
    Plant Based Yogurt Culina Blueberry Lavender Nt Wt 5 oz. (142 g) UPC 854724007117 packaged in glass container 12 jars per case
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-1410-2022·2022-07-13

    Plant-based yogurt recalled due to potential glass contamination

    EAT REAL FOOD LLC is recalling Plant Based Yogurt Culina Mango Orange Blossom due to potential glass contamination. The affected lot code is 07422CBCUCYMOB0723 with best-by date 11/13/2022, distributed nationwide.

    Product
    Plant Based Yogurt Culina Mango Orange Blossom Nt Wt 5 oz. (142 g) UPC 854724007230 packaged in glass container 12 jars per case
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-1406-2022·2022-07-13

    Plant Based Yogurt Recall Due to Potential Glass Contamination

    EAT REAL FOOD LLC is recalling Plant Based Yogurt Culina Bourbon Vanilla in 5 oz. glass jars nationwide due to potential glass fragments in the product. Consumers should not consume products with the affected lot codes.

    Product
    Plant Based Yogurt Culina Bourbon Vanilla Nt Wt 5 oz. (142 g) UPC 854724007094 packaged in glass container 12 jars per case
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1338-2022·2022-07-13

    Rayner RayOne Intraocular Lens Systems Mislabeled with Incorrect Lens Strength

    Rayner is recalling RayOne intraocular lens injection systems because the outer package is mislabeled and contains a different lens strength than indicated. Approximately 162 devices were distributed in 13 US states.

    Product
    RayOne Preloaded Hydrophilic Acrylic IOL Injection Systems containing one MICS injection system with Intraocular Lens: (1) Outer carton labeled as Rayner RayOne EMV US, REF RAO200E, SE: +19.00D, Sph: +19.00D; and (2) Inner primary device packaging labeled as Rayner RayOne…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-1408-2022·2022-07-13

    Plant-Based Strawberry Rose Yogurt Recalled for Potential Glass

    Culina Strawberry Rose plant-based yogurt is being recalled because glass may be present in the product. The recall affects 13,725 cases distributed nationwide.

    Product
    Plant Based Yogurt Culina Strawberry Rose Nt Wt 5 oz. (142 g) UPC 854724007100 packaged in glass container 12 jars per case
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1321-2022·2022-07-13

    ABL800 Flex Analyzer Recalled for Potential Measurement Bias

    Radiometer Medical is recalling ABL800 Flex Analyzers that may produce biased measurements in sodium, calcium, and potassium levels. Approximately 1,489 analyzers are affected worldwide.

    Product
    ABL800 Flex Analyzer Model Numbers 393-800 and 393-801
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-1409-2022·2022-07-13

    Plant-Based Yogurt Recalled for Potential Glass Contamination

    EAT REAL FOOD LLC is recalling Plant Based Yogurt Culina Peach Cashew due to potential glass contamination. The product was distributed nationwide in 13,725 cases.

    Product
    Plant Based Yogurt Culina Peach Cashew Nt Wt 5 oz. (142 g) UPC854724007254 packaged in glass container 12 jars per case
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1322-2022·2022-07-13

    EEA Autosuture Circular Staplers Recalled for Staple Guide Detachment Risk

    Covidien is recalling EEA Autosuture Circular Staplers (25mm) because the staple guide may not be securely attached and could disengage during use, potentially allowing the device to cut tissue without forming staples.

    Product
    EEA Autosuture Circular Stapler with DST Series Technology, 25mm. Model Numbers EEA25, EEAXL25, EEA2535, and EEAXL2535.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-1184-2022·2022-07-13

    Boric Acid Vaginal Suppositories Recalled Due to Manufacturing Control Defects

    Wedgewood Village Pharmacy is recalling Boric Acid 600 mg vaginal suppositories (Lot #000-03843532) nationwide due to insanitary manufacturing conditions and lack of processing controls detected during an FDA inspection. No illnesses have been reported.

    Product
    Boric Acid 600 mg per suppository, 14 Vaginal Suppositories per box, Wedgewood Village Pharmacy LLC, 405 Heron Drive, Ste 200, Swedesboro, NJ 08085
    Category
    Drug
    Distribution
    Distributed nationwide