The Recall Desk

State

New Hampshire product recalls

73,905 recalls have nationwide distribution and so reach New Hampshire. 4,485 additional recalls listed New Hampshire specifically in their distribution scope.

What the numbers show

Total
4,485
Critical
603
Severe
1,049
Most recent
2026-11-11

Of the 4,485 recalls naming New Hampshire we have scored against our rubric, 603 (13%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,049 (23%) are Severe.

These figures cover only the 4,485 recalls whose distribution notice names New Hampshire specifically. The 73,905 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

67826–67850 of 78390

  • HighNHTSA·13V150000·2013-04-19

    Prevost Recalls Coach Buses Due to Incorrect Emergency Window Decals

    Prevost is recalling specific coach buses because emergency window decals omit a required step to open the windows, potentially increasing injury risk in a crash.

    Product
    PREVOST — PREVOST XLII-45 ENTERTAINER, XLII-45, H3-45 VIP, X3-45 VIP
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·13V151000·2013-04-19

    Forest River Recalls 2013 Shasta Revere Trailers Due to Incorrect Tire Labels

    Forest River is recalling 173 model year 2013 Shasta Revere trailers because incorrect tire load and pressure information on labels may lead to overinflation and sudden tire failure.

    Product
    SHASTA REVERE — SHASTA REVERE SHT27DB, SHT30BH, SHT27BH, SHT27KS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • CriticalFDA (Food)·F-1303-2013·2013-04-17

    Nashua Nutrition Recalls Proti Diet Chocolate Dream Bars for Salmonella Risk

    Nashua Nutrition is recalling Proti Diet High Protein Chocolate Dream Bars due to potential Salmonella contamination. Consumers should stop eating the product and return it to the place of purchase.

    Product
    Proti Diet High Protein Chocolate Dream Bar, is sold in 210 g packages (7 bars per package) UPC 6 21498 42238 1
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1066-2013·2013-04-17

    Stelkast Cross-over Acetabular Shell and Liner Hip System Recalled

    Stelkast Co is recalling 254 units of the Cross-over Acetabular Shell and Liner Hip System due to difficulty engaging and securing the liner.

    Product
    Stelkast Cross-over Acetabular Shell and Liner Hip System, Part Numbers SC3458-52, SC3474-52, SC3459-52, and SC3460-52. Intended for use in reconstruction of the articulating surface of the acetabular portion of the hip.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1301-2013·2013-04-17

    Sunchang Ssamjang Sesame and Garlic Bean Paste Recalled for Peanut Mislabeling

    Daesang America is recalling Sunchang Ssamjang bean paste because the English label omits peanut powder, a major allergen listed in Korean.

    Product
    Sunchang Ssamjang Sesame and Garlic Seasoned Bean Paste 500 g - Net Wt. 17.64 oz., UPC Code 880152435671 Distributed by: Daesang America, Inc. Hackensack, NJ 07601 TEL: (201) 488-4010 Product of Korea
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereNHTSA·13V145000·2013-04-17

    E-One Recalls Cyclone II Fire Trucks Due to Brake Fire Risk

    E-One is recalling 2011-2013 Cyclone II fire fighting vehicles because brake chambers may leak, causing brakes to drag and overheat, which could lead to a fire.

    Product
    E-ONE — E-ONE CYCLONE II
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·13V147000·2013-04-17

    Explorer Van Company Recalls 2013 GMC Savana and Chevrolet Express Vans

    Explorer Van Company is recalling 885 model year 2013 Explorer and Explorer Limited SE vans built on GMC Savana and Chevrolet Express chassis due to a wiring harness defect that may cause a fire.

    Product
    GMC — GMC, CHEVROLET SAVANA, EXPRESS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1078-2013·2013-04-17

    GE Healthcare Recalls Infinia Nuclear Medicine Systems Due to Mechanical Failure Risk

    GE Healthcare is recalling Infinia Nuclear Medicine Systems because a mechanical defect could cause the detector to slide, posing a risk to patients and operators.

    Product
    GE Healthcare Quasar Nuclear Medicine System, Hawkeye Option and Hawkeye 4 Option for Dual-Head Variable Angle Gamma Camera. Nuclear Medicine imaging systems. Recall includes all Infinia systems, all configurations.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1299-2013·2013-04-17

    NewChapter Probiotic Elderberry Recalled for Undeclared Soy Allergen

    New Chapter, Inc. is recalling 1,004 bottles of Probiotic Elderberry dietary supplements because they may contain undeclared soy.

    Product
    NewChapter Probiotic Elderberry, 90 vegetarian capsules bottle. Dietary Supplement UPC: 7-27783-00123-8
    Category
    Food
    Distribution
    38 states
  • HighFDA (Devices)·Z-1071-2013·2013-04-17

    J T Posey Recalls Biothane Restraint Cuffs Due to Tensile Strength Defect

    J T Posey Company is voluntarily recalling 1,673 Biothane Restraint Cuffs because they failed to meet tensile strength specifications, posing a risk of disconnection.

    Product
    Posey Biothane Restraint Cuffs, Catalog Number 2900. The device is intended to limit a patient's movement to the extent necessary for treatment or protection of the patient or others.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1097-2013·2013-04-17

    Siemens Recalls Angiographic X-Ray Systems Due to Table Collision Risk

    Siemens is recalling 51 angiographic x-ray systems because a malfunction in the table vertical lift could cause a collision if obstructed by a solid object.

    Product
    Iconos R200 C20, Iconos R200 T20, Iconos R100, Iconos MD, Iconos RHD, Luminos RF Classic, Luminos Fusion or Luminos Select. Angiographic x-ray system.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1085-2013·2013-04-17

    Medtronic Recalls Paradigm Insulin Pumps Due to Cap Detachment Risk

    Medtronic is recalling Paradigm insulin infusion pumps because a drive support cap may detach and allow water to damage internal electronics.

    Product
    Medtronic MiniMed Paradigm Insulin Infusion Pumps Model Numbers: MMT-511, MMT-512, MMT-712, MMT-712E, MMT-515, MMT-715, MMT-522, MMT-522K, MMT-722, MMT-722K, MMT-523, MMT-523K, MMT-723, MMT-723K, MMT-554, and MMT-754. Product Usage: Paradigm insulin infusion pumps are…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1079-2013·2013-04-17

    Thermo Fisher CO2 Incubators Recalled for Hinge Failure

    Thermo Fisher Scientific is recalling 15,567 CO2 incubators manufactured before mid-2009 because their coated metal hinges have reportedly failed in the field.

    Product
    CO2 Incubators (General Purpose Incubator), model numbers 370, 371, 380, 381, 3307, 3308, 3310, 3311, 3540, 3541, 3542, 3543, 3584, 3585, 3598, and 3599. Product Usage: Incubators are designed to maintain an optimal environment for the incubation of tissue and cell samples.…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1061-2013·2013-04-17

    Stryker Recalls Baseplate Impactor Extractor Instruments Due to Handle Detachment

    Stryker Howmedica Osteonics is recalling 871 Baseplate Impactor Extractor instruments because the handle may detach from the cam during surgery.

    Product
    Stryker Orthopaedics Baseplate Impactor Extractor TRIATHLON Instruments. Howmedica Osteonics Corp. 325 Corporate Drive, Mahwah, NJ 07430 USA A subsidiary of Stryker Corporation. Made in USA. Stryker France ZAC Satolas Green Pusignan Av de Satolas Green 69881 MEYZIEU…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1100-2013·2013-04-17

    GE Healthcare Recalls Discovery MR750w Systems Due to Image Flip Defect

    GE Healthcare is recalling 46 Discovery MR750w 3.0T MRI systems worldwide due to a potential image flip issue that may result in incorrect anatomical localization.

    Product
    GE Healthcare, Discovery MR750w 3.0T System. Part Number: 5352293. Product Usage: It is indicated for use as a diagnostic imaging device to produce axial, sagittal, coronal, and oblique images, spectroscopic images, parametric maps, and/or spectra,dynamic images of the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighCPSC·13171·2013-04-17

    Gerbings Recalls 12-Volt Heated Jacket Liners Due to Burn Hazard

    Gerbings is recalling about 9,900 12-volt heated jacket liners sold at Harley-Davidson dealerships and other stores because a defective wire connector can cause overheating and minor burns.

    Product
    12-volt heated jacket liners
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-244-2013·2013-04-17

    GSMS Recalls Lisinopril and Hydrochlorothiazide Tablets Due to Foreign Particulates

    GSMS Inc. is recalling specific lots of Lisinopril and Hydrochlorothiazide tablets because they contain minute stainless steel particulates.

    Product
    LISINOPRIL AND HYDROCHLOROTHIAZIDE TABLETS, USP, 20 mg/25 mg, 100 (NDC 60429-046-01) and 1,000 (NDC 60429-046-10) count bottles, Rx only, GSMS Inc., Camarillo, CA
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighNHTSA·13V146000·2013-04-17

    Navistar Recalls International Trucks Due to Sun Shade Separation Risk

    Navistar is recalling certain 2011-2013 International commercial trucks because sun shades may separate from the roof, potentially distracting the driver and increasing crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL LONESTAR, PROSTAR, DURASTAR, WORKSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1072-2013·2013-04-17

    Elekta Precise Treatment Table Recalled for Column Rotation Defect

    Elekta, Inc. is recalling 443 Precise Treatment Tables because the column rotation can accidentally move from its locked position during radiation therapy.

    Product
    Precise Treatment Table. To be used as part of radiation therapy treatment process.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1083-2013·2013-04-17

    GE Healthcare Recalls VMX Mobile X-ray Units Due to Arm Base Casting Issue

    GE Healthcare is recalling VMX and VMX Plus mobile X-ray units because a defect in the arm base casting may impact operator or patient safety.

    Product
    VMX, VMX Plus Mobile Radiographic Unit with the following models: 45296139; 45296200; 45296350; 45296477; 45296964; 45297001; 45296966; 45297003; 2240169; 2240171; 2240172; 2240173. Product Usage: The VMX is a mobile radiography system incorporating stylish design for…
    Category
    Medical Device
    Distribution
    Distributed nationwide