The Recall Desk

State

Nebraska product recalls

72,992 recalls have nationwide distribution and so reach Nebraska. 4,547 additional recalls listed Nebraska specifically in their distribution scope.

What the numbers show

Total
4,547
Critical
705
Severe
1,119
Most recent
2026-09-09

Of the 4,547 recalls naming Nebraska we have scored against our rubric, 705 (16%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,119 (25%) are Severe.

These figures cover only the 4,547 recalls whose distribution notice names Nebraska specifically. The 72,992 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

8501–8525 of 77539

  • HighFDA (Devices)·Z-0738-2025·2025-01-01

    Siemens Blood Analysis System Software Malfunction May Cause Patient Identification Error

    Siemens epoc NXS Host blood analysis systems are recalled due to a software malfunction that can assign incorrect patient names to blood tests, potentially leading to misdiagnosis or mistreatment.

    Product
    epoc NXS Host; Siemens Material Number (SMN): 11413517(MX) ; Software Version Number: 4.14.9. Intended for use by trained medical professionals as an in vitro diagnostic device for the quantitative testing of samples of heparinized or un-anticoagulated arterial, venous or capi
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0741-2025·2025-01-01

    Siemens epoc blood analyzer software assigns incorrect patient names

    Siemens epoc NXS blood analysis system has a software defect that can incorrectly assign patient names to blood test results, potentially causing misdiagnosis or mistreatment.

    Product
    epoc NXS Host; Siemens Material Number (SMN): 11413879(IN) ; Software Version Number: 4.14.9. Intended for use by trained medical professionals as an in vitro diagnostic device for the quantitative testing of samples of heparinized or un-anticoagulated arterial, venous or capi
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0760-2025·2025-01-01

    RUMMELL Medline Medical Device Weak Seals Sterility Risk Recall

    Medline RUMMELL units may have weak seals that could compromise sterility and increase infection risk. Approximately 21,440 units distributed nationwide are affected.

    Product
    RUMMELL, Medline Item No. ST006ST
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0158-2025·2025-01-01

    Duloxetine Delayed-Release Capsules Recalled Nationwide for Excess N-Nitroso Impurity

    Amerisource Health Services LLC is recalling Duloxetine Delayed-Release Capsules due to N-nitroso-duloxetine impurity above recommended limits. The affected product was distributed nationwide in 1,815 bottles with two specific lot numbers and expiration dates.

    Product
    Duloxetine Delayed-Release Capsules, USP, 60 mg, Rx only, 1,000 count bottles, Manufactured by: Aurobindo Pharma Limited, Hyderabad-500 090, India, For BluePoint Laboratories NDC 68001-415-08
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0747-2025·2025-01-01

    Medical Device Recall: BD FACSLyric Flow Cytometer Power Supply Failure Risk

    BD is recalling power supply modules in FACSLyric flow cytometers that may fail to power on or remain powered. Failure could expose lab staff to fumes and cause patient specimen loss or delayed test results.

    Product
    FACSLyric 3L8C Instrument US-IVD, Catalog Number 662877, UDI 00382906628770 The K170974 clearance document describes the device as follows: The BD FACSLyric" flow cytometer (3-1, 4-2, 4-2-2, and 4-3-3 optical configurations) systems consist of a flow cytometer, sheath tan
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0751-2025·2025-01-01

    Daytona Small Stature Locking Caps recalled for manufacturing defects

    SeaSpine Orthopedics is recalling 92 Daytona Small Stature CoCr Locking Caps due to manufacturing defects that prevent proper component mating. The devices were distributed in seven U.S. states.

    Product
    Brand Name: Daytona Small Stature Product Name: CoCr LockingCap 4.5mm, Small Stature, T25, BT Model/Catalog Number: 79-0002 Software Version: N/A Product Description: Locking Cap Component: No
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0723-2025·2025-01-01

    Medline surgical patties and strips recalled for endotoxin contamination

    Medline surgical patties and strips used in certain procedure convenience kits were found to contain higher-than-expected endotoxin levels that may exceed safety specifications. The affected kits were distributed nationwide and in Canada.

    Product
    Medline brand, medical procedure convenience kits, labeled as: 1) CRANIOTOMY, SKU CDS982719X; 2) MVFF/FIBU #54-RF, SKU DYNJ21927Q; 3) MVFF/FIBU #54-RF, SKU DYNJ21927S; 3) NEURO PEDIATRIC, SKU DYNJ61607A; 4) CRANIOTOMY PACK, SKU DYNJ66419C; 5) LYMPHATIC BYPASS PACK, SKU DYNJ69907;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0159-2025·2025-01-01

    Prescription chlorpromazine tablets recalled due to manufacturing quality defect

    Glenmark Pharmaceuticals is recalling chlorpromazine hydrochloride 10mg tablets nationwide due to manufacturing deviations that allowed excess N-nitroso impurity.

    Product
    CHLORPROMAZINE HYDROCHLORIDE — CHLORPROMAZINE HYDROCHLORIDE (CHLORPROMAZINE HYDROCHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0750-2025·2025-01-01

    BYTE Aligner System Recalled for Virtual-Only Approval Workflow Gaps

    Straight Smile LLC is recalling BYTE Aligner systems due to a virtual-only clinical workflow that may not adequately screen patients with contraindications for aligner use. Approximately 5.3 million devices are affected.

    Product
    BYTE Aligner System REF PRS-0063 BYTE All-Day Aligner System BYTE AT-Night Aligner System A custom-made orthodontic appliance, typically supplied in series intended to be worn in succession and self-changed every few weeks, designed to influence the shape and/or function o
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0761-2025·2025-01-01

    EMPOWR 3D Knee Tibial Insert Recalled for Wrong Product in Package

    Encore Medical is recalling 9 units of EMPOWR 3D Knee Tibial Insert (Lot 076T1273A) because packages may contain an acetabular system instead of the intended knee insert, potentially causing surgical delays.

    Product
    EMPOWR 3D Knee Tibial Insert, 6R 10MM, VE, REF: 342-10-706
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0769-2025·2025-01-01

    Hip Reconstruction System Component Mislabeled for Size

    Waldemar Link is recalling 3 units of the LINK MP Reconstruction System Neck Segment due to a labeling error indicating the wrong size (XXL instead of standard), though all other specifications on the labels are correct.

    Product
    LINK MP Reconstruction System Neck Segment (with suture holes, standard, uncemented, L= 35 mm, CCD 126¿, Offset= 31 mm, Ti6Al4V, PoroLink, Taper 12/14. Item Number: 99-0984/32 Intended for revision hip arthroplasty in patients whose bone stock is of poor quality or inadeq
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0729-2025·2025-01-01

    O&M Halyard Surgical Masks Recalled for Failing Bioburden Testing

    O&M Halyard SOFT TOUCH II Surgical Masks (lot AM4119961) are being recalled for not meeting EN 14683 bioburden testing standards printed on the packaging. No illnesses or injuries have been reported.

    Product
    O&M Halyard SOFT TOUCH II Surgical Mask, Blue-Disposable surgical mask Product Code: 47500
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V824000·2024-12-30

    Winnebago motorhome door windows can loosen and detach during transit

    Winnebago is recalling certain 2020-2024 View and Navion RVs with Lippert Metallarte door assemblies because incorrect window adhesion can cause the window to loosen or detach.

    Product
    WINNEBAGO — WINNEBAGO VIEW, NAVION
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereCPSC·25078·2024-12-26

    Precor Resolute cable exercise equipment recalled for pulley drop hazard

    Precor recalls about 834 Resolute Cable exercise units; the pop-pin can fail, causing the pulley carriage to drop unexpectedly. The company received 9 reports of pulley drops, including 2 minor head injuries.

    Product
    Precor Resolute Cable Multi-Station Exercise Equipment
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereCPSC·25080·2024-12-26

    Inclusive Orbit merry-go-rounds recalled due to finger crush hazard

    About 415 Inclusive Orbit merry-go-rounds are recalled due to a crushing hazard where the gap between the rotating platform and outer rim narrows, trapping children's fingers. Two finger crushing injuries have been reported.

    Product
    Inclusive Orbit merry-go-rounds
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·25079·2024-12-26

    GIKPAL 12-Drawer Dressers Recalled for Tip-Over and Entrapment Hazards

    GIKPAL 12-Drawer Dressers are being recalled because they can tip over and trap children if not anchored to a wall. About 800 units were sold on Walmart.com; consumers should stop using them and contact ONME Direct for a refund.

    Product
    GIKPAL 12-Drawer Dressers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·25077·2024-12-26

    Avalanche Transceivers Recalled for Battery Contact Failure Risk

    Black Diamond recalls 770 PIEPS Pro IPS Avalanche Transceivers due to battery contact failure that could prevent operation during emergencies. Units were sold from February through November 2024 for $530–$620.

    Product
    PIEPS Pro IPS Avalanche Transceivers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0654-2025·2024-12-25

    Kirwan Surgical Disposable Bipolar Pencils recalled for potential tube failure

    Kirwan Surgical Products is recalling 80,060 Disposable Bipolar Pencils (Model 14-5011) because the outer stainless-steel tube may break or detach during surgical use. The devices were distributed worldwide.

    Product
    Kirwan Surgical Products LLC Disposable 25-gauge bipolar pencil, straight. Model/Catalog Number: 14-5011 The Disposable Microsurgical Bipolar Pencil are designed for use in eye surgery, and other soft tissue procedures. For instance, the pencils are designed for cauterization
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-0290-2025·2024-12-25

    Carrot falafel product recalled for potential E. coli contamination

    Fabalish Inc.'s Kickin brand carrot falafel is being recalled due to potential E. coli contamination. Consumers should not consume the product.

    Product
    Fabalish Inc. , Kickin, Carrot Falafel , 10oz , Cardboard tray inside plastic film inside cardboard box, individual units
    Category
    Food
    Distribution
    18 states
  • SevereFDA (Devices)·Z-0659-2025·2024-12-25

    Nidek Disposable Bipolar Pencil Surgical Instruments Recalled for Tube Breakage Risk

    Kirwan Surgical Products recalls Nidek Disposable Bipolar Pencil surgical instruments due to risk that the stainless-steel tube may break or detach during procedures.

    Product
    Nidek Co. Disposable Bipolar Pencil 25 Gauge Straight. Model/Catalog Number: 18241-0979. Product Description: The Disposable Microsurgical Bipolar Pencil are designed for use in eye surgery, and other soft tissue procedures. For instance, the pencils are designed for cauteriza
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0662-2025·2024-12-25

    Exacta External Drainage System Stopcocks May Leak or Crack

    Medtronic Neurosurgery is recalling Exacta External Drainage and Monitoring Systems worldwide due to complaints of cracking and leaking stopcocks. These components control cerebrospinal fluid drainage and intracranial pressure monitoring.

    Product
    Exacta External Drainage and Monitoring System: 27581 KIT 27581 EXACTA W/EDM VCATH 35CM 27636 EDM 27636 EXACTA W/BRAIDED CORD LOCK 27666 EDM 27666 EXCTA W GLUE STPCK GR PT LN 27732 EDM 27732 EXACTA W/NDL-LS INJ. ST W/CAP 27785 EDMS 27785 EXACTA 50ML BC NDLESS INJ 27795 EDMS
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0656-2025·2024-12-25

    Surgical Bipolar Pencil Recall: Risk of Tube Breakage During Eye Surgery

    Kirwan Surgical Products is recalling disposable bipolar surgical pencils used in eye surgery because the outer stainless-steel tube may break or detach during use.

    Product
    Accutome/Microsurgical Disposable Bipolar Pencil 5 in. (12.7cm) 25 Gauge Straight. Model/Catalog Number: AB-7004 The Disposable Microsurgical Bipolar Pencil are designed for use in eye surgery, and other soft tissue procedures. For instance, the pencils are designed for cauter
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0661-2025·2024-12-25

    Medtronic Becker Neurosurgical Drainage Systems Recalled for Cracked and Leaking Stopcocks

    Medtronic Neurosurgery recalls Becker External Drainage and Monitoring Systems due to reports of cracks and leaks in stopcocks. The recalled systems are used to drain cerebrospinal fluid and monitor pressure in neurosurgery patients.

    Product
    Becker External Drainage and Monitoring System: 24146 EDMS 24146 BECKER NO Y-SITE 25120 EDMS II 25120 BECKER W/1-WAY VALVE 26040 KIT 26040 BECKER EDMS II 27609 BECKER 27609 W/NEEDLESLESS INJ. SITE 27670 BECKER 27670 STOP BELOW DC NDL-LS IN 27672 BECKER 27672 ONEWAY VLV Y-SI
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0655-2025·2024-12-25

    Kirwan Surgical Bipolar Pencil Recalled Due to Potential Tube Breakage

    Kirwan Surgical Products is recalling its Disposable 25-gauge Bipolar Pencil (Model 14-5011L) because the outer stainless-steel tube may break or detach during use. The defect could create a safety hazard during eye surgery and other soft tissue procedures.

    Product
    Kirwan Surgical Products LLC Disposable 25-gauge bipolar pencil, straight, Long. Model/Catalog Number: 14-5011L The Disposable Microsurgical Bipolar Pencil are designed for use in eye surgery, and other soft tissue procedures. For instance, the pencils are designed for cauteri
    Category
    Medical Device
    Distribution
    Distributed nationwide