The Recall Desk

State

Nebraska product recalls

73,892 recalls have nationwide distribution and so reach Nebraska. 4,581 additional recalls listed Nebraska specifically in their distribution scope.

What the numbers show

Total
4,581
Critical
713
Severe
1,345
Most recent
2026-11-11

Of the 4,581 recalls naming Nebraska we have scored against our rubric, 713 (16%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,345 (29%) are Severe.

These figures cover only the 4,581 recalls whose distribution notice names Nebraska specifically. The 73,892 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

71451–71475 of 78473

  • SevereNHTSA·12V107000·2012-03-21

    Porsche Recalls 2012 911 Carrera S Vehicles for Fuel Line Defect

    Porsche is recalling 1,232 model year 2012 911 Carrera S vehicles because a coolant line may interfere with a fuel line, causing a leak that could lead to stalling or fire.

    Product
    PORSCHE — PORSCHE 911 CARRERA S
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·12135·2012-03-21

    Westinghouse Ceiling Fans Recalled for Shock and Fire Hazards

    Westinghouse Lighting is recalling about 7,000 ceiling fans because included light bulbs exceed maximum wattage, posing fire and shock risks.

    Product
    Ceiling Fans
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V109000·2012-03-20

    Webasto Sunroof Recall: Glass May Separate From Vehicle Frame

    Webasto is recalling certain sunroofs installed by Jeffco Auto Trim and Glass because the adhesive bond may fail, causing the glass to separate from the vehicle.

    Product
    VISIBILITY:SUN/MOON ROOF ASSEMBLY recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V105000·2012-03-20

    Gulf Stream Recalls 2001-2005 Recreational Vehicles Due to Wiring Fire Risk

    Gulf Stream is recalling specific 2001-2005 recreational vehicles because unsecured wiring may cause heat and fire. Owners should contact dealers for free repairs.

    Product
    GULF STREAM — GULF STREAM ULTRA, CONQUEST, ENDURA, INDEPENDENCE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V128000·2012-03-20

    Webasto Sunroof Glass Debonding Recall for Coach Automotive Vehicles

    Webasto is recalling certain sunroofs installed by Coach Automotive Restyling because the glass can separate from the frame, creating a road hazard.

    Product
    VISIBILITY:SUN/MOON ROOF ASSEMBLY recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·12134·2012-03-20

    Bon Hiver Recalls Freebase Snowboard Bindings Due to Base Plate Fracture Hazard

    Bon Hiver is recalling Freebase snowboard bindings because the base plate can fracture during use, posing a fall hazard. Consumers should stop using the products and return them for a free repair and partial refund.

    Product
    Snowboard Bindings
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V104000·2012-03-19

    Webasto Sunroof Recall Due to Glass Separation Risk

    Webasto is recalling certain sunroofs installed by Cyclone Auto Seat Cover because the glass may separate from the frame, creating a road hazard.

    Product
    VISIBILITY:SUN/MOON ROOF ASSEMBLY recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V103000·2012-03-19

    Webasto Sunroof Recall Due to Glass Separation Risk

    Webasto is recalling certain sunroofs installed by National Auto Spa because the glass may separate from the frame, creating a road hazard.

    Product
    VISIBILITY:SUN/MOON ROOF ASSEMBLY recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·12V215000·2012-03-19

    Tiffin Allegro Motorhomes Recalled for Gear Shift Cable Defect

    Tiffin is recalling 2010-2012 Allegro motorhomes because a gear shift cable may break, causing the gear indicator to display incorrectly and increasing crash risk.

    Product
    TIFFIN — TIFFIN ALLEGRO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·12E010000·2012-03-15

    Land Rover Recalls Rear Driveshaft Couplings for Crash Risk

    Jaguar Land Rover is recalling certain rear driveshaft couplings for 1995-2004 Land Rover Discovery and Range Rover Classic vehicles. The parts may fail, causing loss of drive and increasing crash risk.

    Product
    LAND ROVER — LAND ROVER, RANGE ROVER DISCOVERY II, DISCOVERY, CLASSIC
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·12727·2012-03-15

    Kawasaki Recalls Utility Vehicles Due to Fuel Tube Fire Hazard

    Kawasaki is recalling about 3,900 model year 2012 utility vehicles because a fuel tube can scrape against the air cleaner housing, posing a fire hazard.

    Product
    Utility Vehicles
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V101000·2012-03-14

    Volvo Recalls 2012 S60 and XC60 for Fuel Line Fire Risk

    Volvo is recalling 2012 S60 and XC60 vehicles because underbody coating may damage fuel lines, causing leaks and increasing fire risk.

    Product
    VOLVO — VOLVO S60, XC60
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • ModerateNHTSA·12V102000·2012-03-14

    Nissan Titan Recall: Incorrect Tire Placard Seating Capacity Information

    Nissan is recalling certain 2012 Titan vehicles with the Sports Appearance Package because the tire placard displays incorrect seating capacity information, which may lead to vehicle overloading.

    Product
    NISSAN — NISSAN TITAN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·12131·2012-03-13

    Guidecraft Recalls 4-in-1 Play Theaters Due to Tip-Over Hazard

    Guidecraft is recalling 4-in-1 Dramatic Play Theater Toys because they can tip over, posing an entrapment hazard to young children.

    Product
    4-in-1 Dramatic Play Theater Toys
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·12V100000·2012-03-13

    Trans Tech Horizon Transit Bus Seat Belt Anchor Recall

    Two 2011 Trans Tech Horizon buses are recalled because seat belt anchorages may not meet federal safety standards, increasing injury risk in a crash.

    Product
    TRANS TECH — TRANS TECH HORIZON
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·12V099000·2012-03-13

    Subaru Forester Recall for Rear Center Seat Belt Defect

    Subaru is recalling 2009-2012 Foresters because the rear center seat belt may not secure child restraints properly, increasing injury risk in a crash.

    Product
    SUBARU — SUBARU FORESTER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·12132·2012-03-13

    Hydro-Gear Recalls Lawn Tractors Due to Brake Failure Crash Hazard

    Hydro-Gear is recalling about 2,700 Cub Cadet, MTD Gold, and Troy-Bilt lawn tractors because a drive gear failure can cause brake failure, posing a crash hazard.

    Product
    Lawn Tractors
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V096000·2012-03-08

    Mack LEU and MRU Trucks Recalled for Electrical Fire Risk

    Mack is recalling 318 natural gas LEU and MRU trucks because an alternator ground cable defect may cause a vehicle fire during an electrical short.

    Product
    MACK — MACK LEU, MRU
    Category
    Vehicle
    Distribution
    Distributed nationwide