71351–71375 of 82169

  • CriticalFDA (Food)·F-1303-2013·2013-04-17

    Nashua Nutrition Recalls Proti Diet Chocolate Dream Bars for Salmonella Risk

    Nashua Nutrition is recalling Proti Diet High Protein Chocolate Dream Bars due to potential Salmonella contamination. Consumers should stop eating the product and return it to the place of purchase.

    Product
    Proti Diet High Protein Chocolate Dream Bar, is sold in 210 g packages (7 bars per package) UPC 6 21498 42238 1
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1051-2013·2013-04-17

    GE Healthcare Recalls Giraffe OmniBed and Incubator Units for Display Errors

    GE Healthcare is recalling 679 Giraffe OmniBed and Incubator units because display boards may randomly overwrite stored information and set points upon power up or recovery from a power failure.

    Product
    Giraffe OmniBed¿ and Giraffe Incubator p/n 6600-0723-700 (rev A and B) labeled in part: ***GE Healthcare 8880 Gorman Road Laurel, MD 20723 U.S.A. www.gehealthcare.com***. GE Healthcare Giraffe Omnibed is a combination of an infant incubator and an infant warmer.
    Category
    Medical Device
    Distribution
    29 states
  • SevereFDA (Devices)·Z-1066-2013·2013-04-17

    Stelkast Cross-over Acetabular Shell and Liner Hip System Recalled

    Stelkast Co is recalling 254 units of the Cross-over Acetabular Shell and Liner Hip System due to difficulty engaging and securing the liner.

    Product
    Stelkast Cross-over Acetabular Shell and Liner Hip System, Part Numbers SC3458-52, SC3474-52, SC3459-52, and SC3460-52. Intended for use in reconstruction of the articulating surface of the acetabular portion of the hip.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1300-2013·2013-04-17

    Nutrex Research Recalls Lipo 6 Black Ultra Concentrate Due to DMAA

    Nutrex Research is recalling Lipo 6 Black Ultra concentrate Fat Destroyer because samples contain DMAA (Methylhexanamine). The recall affects 82,417 sample packets distributed in eight states.

    Product
    Nutrex Research Lipo 6 Black Ultra concentrate Fat Destroyer
    Category
    Food
    Distribution
    8 states
  • SevereFDA (Food)·F-1301-2013·2013-04-17

    Sunchang Ssamjang Sesame and Garlic Bean Paste Recalled for Peanut Mislabeling

    Daesang America is recalling Sunchang Ssamjang bean paste because the English label omits peanut powder, a major allergen listed in Korean.

    Product
    Sunchang Ssamjang Sesame and Garlic Seasoned Bean Paste 500 g - Net Wt. 17.64 oz., UPC Code 880152435671 Distributed by: Daesang America, Inc. Hackensack, NJ 07601 TEL: (201) 488-4010 Product of Korea
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereNHTSA·13V145000·2013-04-17

    E-One Recalls Cyclone II Fire Trucks Due to Brake Fire Risk

    E-One is recalling 2011-2013 Cyclone II fire fighting vehicles because brake chambers may leak, causing brakes to drag and overheat, which could lead to a fire.

    Product
    E-ONE — E-ONE CYCLONE II
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·13V147000·2013-04-17

    Explorer Van Company Recalls 2013 GMC Savana and Chevrolet Express Vans

    Explorer Van Company is recalling 885 model year 2013 Explorer and Explorer Limited SE vans built on GMC Savana and Chevrolet Express chassis due to a wiring harness defect that may cause a fire.

    Product
    GMC — GMC, CHEVROLET SAVANA, EXPRESS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1078-2013·2013-04-17

    GE Healthcare Recalls Infinia Nuclear Medicine Systems Due to Mechanical Failure Risk

    GE Healthcare is recalling Infinia Nuclear Medicine Systems because a mechanical defect could cause the detector to slide, posing a risk to patients and operators.

    Product
    GE Healthcare Quasar Nuclear Medicine System, Hawkeye Option and Hawkeye 4 Option for Dual-Head Variable Angle Gamma Camera. Nuclear Medicine imaging systems. Recall includes all Infinia systems, all configurations.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1299-2013·2013-04-17

    NewChapter Probiotic Elderberry Recalled for Undeclared Soy Allergen

    New Chapter, Inc. is recalling 1,004 bottles of Probiotic Elderberry dietary supplements because they may contain undeclared soy.

    Product
    NewChapter Probiotic Elderberry, 90 vegetarian capsules bottle. Dietary Supplement UPC: 7-27783-00123-8
    Category
    Food
    Distribution
    38 states
  • HighFDA (Devices)·Z-1071-2013·2013-04-17

    J T Posey Recalls Biothane Restraint Cuffs Due to Tensile Strength Defect

    J T Posey Company is voluntarily recalling 1,673 Biothane Restraint Cuffs because they failed to meet tensile strength specifications, posing a risk of disconnection.

    Product
    Posey Biothane Restraint Cuffs, Catalog Number 2900. The device is intended to limit a patient's movement to the extent necessary for treatment or protection of the patient or others.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1097-2013·2013-04-17

    Siemens Recalls Angiographic X-Ray Systems Due to Table Collision Risk

    Siemens is recalling 51 angiographic x-ray systems because a malfunction in the table vertical lift could cause a collision if obstructed by a solid object.

    Product
    Iconos R200 C20, Iconos R200 T20, Iconos R100, Iconos MD, Iconos RHD, Luminos RF Classic, Luminos Fusion or Luminos Select. Angiographic x-ray system.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1085-2013·2013-04-17

    Medtronic Recalls Paradigm Insulin Pumps Due to Cap Detachment Risk

    Medtronic is recalling Paradigm insulin infusion pumps because a drive support cap may detach and allow water to damage internal electronics.

    Product
    Medtronic MiniMed Paradigm Insulin Infusion Pumps Model Numbers: MMT-511, MMT-512, MMT-712, MMT-712E, MMT-515, MMT-715, MMT-522, MMT-522K, MMT-722, MMT-722K, MMT-523, MMT-523K, MMT-723, MMT-723K, MMT-554, and MMT-754. Product Usage: Paradigm insulin infusion pumps are…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1079-2013·2013-04-17

    Thermo Fisher CO2 Incubators Recalled for Hinge Failure

    Thermo Fisher Scientific is recalling 15,567 CO2 incubators manufactured before mid-2009 because their coated metal hinges have reportedly failed in the field.

    Product
    CO2 Incubators (General Purpose Incubator), model numbers 370, 371, 380, 381, 3307, 3308, 3310, 3311, 3540, 3541, 3542, 3543, 3584, 3585, 3598, and 3599. Product Usage: Incubators are designed to maintain an optimal environment for the incubation of tissue and cell samples.…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1061-2013·2013-04-17

    Stryker Recalls Baseplate Impactor Extractor Instruments Due to Handle Detachment

    Stryker Howmedica Osteonics is recalling 871 Baseplate Impactor Extractor instruments because the handle may detach from the cam during surgery.

    Product
    Stryker Orthopaedics Baseplate Impactor Extractor TRIATHLON Instruments. Howmedica Osteonics Corp. 325 Corporate Drive, Mahwah, NJ 07430 USA A subsidiary of Stryker Corporation. Made in USA. Stryker France ZAC Satolas Green Pusignan Av de Satolas Green 69881 MEYZIEU…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1096-2013·2013-04-17

    GE Healthcare Recalls LOGIQ Ultrasound Systems Due to Potential Skin Burn Risk

    GE Healthcare is recalling LOGIQ S8 and S7 ultrasound systems equipped with the S4-10-D probe due to a potential safety issue that may cause skin burns.

    Product
    GE Healthcare LOGIQ S8 (with software revisions R1.1.1 and R1.5.1) and LOGIQ S7 (with software revisions R1.0.1, R1.0.2 and R1.0.3) diagnostic ultrasound system with the S4-10-D Ultrasound Probe. The device is intended for use in ultrasound evaluation.
    Category
    Medical Device
    Distribution
    40 states
  • HighFDA (Devices)·Z-1100-2013·2013-04-17

    GE Healthcare Recalls Discovery MR750w Systems Due to Image Flip Defect

    GE Healthcare is recalling 46 Discovery MR750w 3.0T MRI systems worldwide due to a potential image flip issue that may result in incorrect anatomical localization.

    Product
    GE Healthcare, Discovery MR750w 3.0T System. Part Number: 5352293. Product Usage: It is indicated for use as a diagnostic imaging device to produce axial, sagittal, coronal, and oblique images, spectroscopic images, parametric maps, and/or spectra,dynamic images of the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighCPSC·13171·2013-04-17

    Gerbings Recalls 12-Volt Heated Jacket Liners Due to Burn Hazard

    Gerbings is recalling about 9,900 12-volt heated jacket liners sold at Harley-Davidson dealerships and other stores because a defective wire connector can cause overheating and minor burns.

    Product
    12-volt heated jacket liners
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-244-2013·2013-04-17

    GSMS Recalls Lisinopril and Hydrochlorothiazide Tablets Due to Foreign Particulates

    GSMS Inc. is recalling specific lots of Lisinopril and Hydrochlorothiazide tablets because they contain minute stainless steel particulates.

    Product
    LISINOPRIL AND HYDROCHLOROTHIAZIDE TABLETS, USP, 20 mg/25 mg, 100 (NDC 60429-046-01) and 1,000 (NDC 60429-046-10) count bottles, Rx only, GSMS Inc., Camarillo, CA
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighNHTSA·13V146000·2013-04-17

    Navistar Recalls International Trucks Due to Sun Shade Separation Risk

    Navistar is recalling certain 2011-2013 International commercial trucks because sun shades may separate from the roof, potentially distracting the driver and increasing crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL LONESTAR, PROSTAR, DURASTAR, WORKSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1072-2013·2013-04-17

    Elekta Precise Treatment Table Recalled for Column Rotation Defect

    Elekta, Inc. is recalling 443 Precise Treatment Tables because the column rotation can accidentally move from its locked position during radiation therapy.

    Product
    Precise Treatment Table. To be used as part of radiation therapy treatment process.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1083-2013·2013-04-17

    GE Healthcare Recalls VMX Mobile X-ray Units Due to Arm Base Casting Issue

    GE Healthcare is recalling VMX and VMX Plus mobile X-ray units because a defect in the arm base casting may impact operator or patient safety.

    Product
    VMX, VMX Plus Mobile Radiographic Unit with the following models: 45296139; 45296200; 45296350; 45296477; 45296964; 45297001; 45296966; 45297003; 2240169; 2240171; 2240172; 2240173. Product Usage: The VMX is a mobile radiography system incorporating stylish design for…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1062-2013·2013-04-17

    Synthes Flexible Grip Recalled for Cleaning Limitations

    Synthes USA is voluntarily recalling 328 Flexible Grip instruments from the Universal Nail System because they may not be thoroughly cleaned.

    Product
    Flexible Grip which is part of the Synthes Universal Nail System. Indicated for the conventional (non-locking) technique of treating stable diaphyseal fractures.
    Category
    Medical Device
    Distribution
    Distributed nationwide