  • SevereFDA (Devices)·Z-1820-2018·2018-05-23

    Medtronic Recalls Endo GIA Stapler Loading Units Due to Missing Sled

    Medtronic is recalling 171,271 Endo GIA Auto Suture Universal Articulating Loading Units because a missing sled component may prevent staple formation, leading to bleeding or leakage.

    Product
    Endo GIA" Auto Suture" Universal Articulating Loading Unit 60mm - 3.5mm ( Item Code 030458) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1822-2018·2018-05-23

    Medtronic Endo GIA Stapler Reloads Recalled for Missing Sled Component

    Medtronic is recalling Endo GIA 30mm stapler reloads because a missing sled component may cause staple failure, leading to bleeding or leakage.

    Product
    Endo GIA" 30mm Gray Curved Tip Articulating Vascular Reload with Tri-Staple" Technology( Item Code EGIA30AV) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1444-2018·2018-05-23

    eBars Recalls Organic Peanut Butter Bars for Undeclared Almonds

    eBars is recalling FIT Organic Peanut Butter Chocolate Raspberry bars because they contain undeclared almonds. The recall was initiated after notification from the State of Tennessee.

    Product
    FIT ORGANIC PEANUT BUTTER CHOCOLATE RASPBERRY bar NET WT 1.8 OZ (51g) Manufactured and Distributed by eBars, LLC, Franklin, TN 37064 UPC 8 55529 00443 1
    Category
    Food
    Distribution
    40 states
  • SevereFDA (Devices)·Z-1837-2018·2018-05-23

    Medtronic Endo GIA Universal Bypass Kits Recalled for Missing Sled Component

    Medtronic is recalling specific Endo GIA Universal Bypass Kits because a missing sled component may prevent staple formation, potentially causing bleeding or leakage.

    Product
    KIT-DE-0080 BYPASS KIT LOHNE X1( Item KIT-DE-0080) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1849-2018·2018-05-23

    Medtronic Recalls Bariatric Staplers Due to Missing Sled Component

    Medtronic is recalling specific bariatric stapler kits because a missing sled component may prevent staple formation, potentially causing bleeding or leakage.

    Product
    (1)BOX PST01199 BARIATRIC TRISTAPLE (Item Number: PST01199) (2) BOX PST03403 ALTERNATIVE APPENDIX KIT (Item Number: PST03403) (3) BOX PST03533 KIT APP STAPLER (Item Number: PST03403) Product Usage: The Endo GIA universal and…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1832-2018·2018-05-23

    COVIDIEN Medtronic Recalls Endo GIA Stapler Kits Due to Missing Sled

    COVIDIEN Medtronic is recalling Endo GIA universal stapler kits because a missing sled component may prevent proper staple deployment, risking bleeding or leakage.

    Product
    BOX KIT00713 KIT BY PASS Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the staples is determined by the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1451-2018·2018-05-23

    eBars Recalls Run Organic Chocolate Almond Bars for Peanut Allergen

    eBars is recalling Run Organic Chocolate Almond bars because they tested positive for peanut, an allergen not declared on the label.

    Product
    RUN ORGANIC CHOCOLATE ALMOND bar NET WT. 1.6 OZ (45g) Manufactured and Distributed by eBars, LLC, Franklin, TN 37064 UPC 8 55529 00404 2
    Category
    Food
    Distribution
    40 states
  • SevereFDA (Food)·F-1450-2018·2018-05-23

    eBars Recalls Organic Chocolate Almond Bars Due to Peanut Allergen

    eBars is recalling 48,969 units of MAN Organic Chocolate Almond bars because they tested positive for peanut, an undeclared allergen.

    Product
    MAN ORGANIC CHOCOLATE ALMOND bar NET WT. 1.8 OZ (51g) Manufactured and Distributed by eBars, LLC, Franklin, TN 37064 UPC 8 55529 00414 1
    Category
    Food
    Distribution
    40 states
  • SevereFDA (Drugs)·D-0840-2018·2018-05-23

    Apotex Recalls Subpotent Piperacillin and Tazobactam Injection Vials

    Apotex Inc. is recalling specific lots of Piperacillin and Tazobactam for Injection due to high impurity levels that decreased the drug's potency.

    Product
    Piperacillin and Tazobactam for Injection, USP 4.5 gram/vial* 10-count Single Use Vials per carton, Rx only, Mfg. by: Hospira Healthcare India Pvt. Ltd. Irungattukottai-602 105, India Mfg. for: Apotex Corp. Weston, FL 33326. NDC 60505-0688-4
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1839-2018·2018-05-23

    Medtronic Recalls Bypass Kits Due to Missing Stapler Component

    Medtronic is recalling 171,271 Endo GIA Bypass Kits because a missing sled component may prevent staple formation, potentially causing bleeding or leakage.

    Product
    BOX KITDE0108 BYPASS KIT LUEBECK ( KITDE0108) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the staples…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1831-2018·2018-05-23

    Medtronic Endo GIA Staplers Recalled for Missing Sled Component

    Medtronic is recalling Endo GIA universal staplers because a missing sled component may prevent staple formation, potentially causing bleeding or leakage.

    Product
    KIT00486R OBESIDAD D. WORWARLD 2 X1 (Item Number KIT00486R) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1445-2018·2018-05-23

    eBars Recalls Organic Chocolate Peanut Bars for Undeclared Almonds

    eBars is recalling FOCUS Organic Chocolate Peanut bars because they contain undeclared almonds. The recall affects 33,115 units shipped to multiple states.

    Product
    FOCUS ORGANIC CHOCOLATE PEANUT bar NET WT. 1.6 OZ (45g) Manufactured and Distributed by eBars, LLC, Franklin, TN 37064 UPC 8 55529 00417 2
    Category
    Food
    Distribution
    40 states
  • SevereFDA (Devices)·Z-1834-2018·2018-05-23

    Medtronic Endo GIA Universal Staplers Recalled for Missing Sled Component

    Medtronic is recalling Endo GIA Universal staplers because a missing sled component may prevent staple formation, potentially causing bleeding or leakage.

    Product
    BOX KIT1171C KIT LAP CYSTECTOMY Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the staples is determined…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1844-2018·2018-05-23

    Medtronic Endo GIA Staplers Recalled for Missing Sled Component

    Medtronic is recalling Endo GIA universal staplers because a missing sled component may prevent staple formation, potentially causing bleeding or leakage.

    Product
    BOX LAPIMBGP1 ZESTAW DO MGBP (LAPIMBGP1) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the staples is…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1854-2018·2018-05-23

    Medtronic Endo GIA Universal Staplers Recalled for Missing Sled Component

    Medtronic is recalling Endo GIA Universal and Universal XL staplers because a missing sled component may prevent staple formation, leading to bleeding or leakage.

    Product
    BOX PST03699 KIT APP MED ALTERNATIV STAP Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the staples is…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1805-2018·2018-05-23

    Zimmer Biomet Recalls Persona Stemmed Tibial Provisional Instruments

    Zimmer Biomet is recalling 842 Persona Stemmed Tibial Provisional instruments due to potential cracks in the raw material that could compromise cleanliness.

    Product
    Persona Stemmed Tibial Provisional Size H Left, Item Number 42532108301 For use during orthopaedic surgery for implantation of a prosthesis.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1812-2018·2018-05-23

    Tosoh HbA1c Pretreatment Solution Recalled for Potential Inaccurate Test Results

    Tosoh Bioscience Inc is recalling HbA1c Pretreatment Solution because it may cause erroneously elevated or decreased patient test results.

    Product
    Tosoh ST AIA-PACK HbA1c Pretreatment Solution, HbA1c Pretreatment Solution, PN 025718 The device is intended for In Vitro Diagnostic Use Only for the pretreatment of the patient samples or control set for the HbA1c assay
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1808-2018·2018-05-23

    Zimmer Biomet Recalls Persona Cemented Tibial Plate Due to Cracks

    Zimmer Biomet is recalling 842 Persona Cemented Tibial Plate units because potential cracks in the raw material could compromise the cleanliness of the instruments.

    Product
    Persona Cemented Tibial SZ PLT Size H Right, Item Number 42539908302 For use during orthopaedic surgery for implantation of a prosthesis.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·18V337000·2018-05-23

    Land Rover Recalls 2017 Models for Fuel Gauge Software Error

    Jaguar Land Rover is recalling 2017 Range Rover, Range Rover Sport, and Discovery vehicles because a software error may cause the engine to shut off unexpectedly.

    Product
    LAND ROVER — LAND ROVER RANGE ROVER SPORT, DISCOVERY, RANGE ROVER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1871-2018·2018-05-23

    Kelyniam Custom Skull Implant Recalled for Unvalidated Design Changes

    Kelyniam Global is recalling 16 Custom Skull Implants because significant design changes were not validated or submitted to the FDA for marketing clearance.

    Product
    Kelyniam Custom Skull Implant (CSI), Model no. PEEK-IM1002
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1813-2018·2018-05-23

    Draeger Infinity Acute Care System Recalled for Software Anomaly

    Draeger Medical Systems is recalling the Infinity Acute Care System due to a software anomaly that can cause loss of patient settings and stored data.

    Product
    Infinity Acute Care System (lACS) Monitoring Solution; Catalog Numbers:MS20401, MS20724, MS22956, MS25510, MS25520, MS25643, MS26196, MS26372, MS31818; UDI Information: 4049098054454, 4049098054447, 4049098054409, 4049098009799, 4049098009751. Multi-parameter, physiologic…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1872-2018·2018-05-23

    Kelyniam Custom Skull Implant Recall for Unvalidated Design Changes

    Kelyniam Global is recalling 23 Custom Skull Implants because significant design changes were not validated or submitted to the FDA for clearance.

    Product
    Kelyniam Custom Skull Implant (CSI), Model no. PEEK-IM1003
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1881-2018·2018-05-23

    Visaris Diagnostic X-Ray Systems Recalled for Tube Arm Suspension Failure Risk

    Visaris DOO is recalling 22 diagnostic X-ray systems worldwide due to a potential failure of the tube arm suspension that could cause an uncontrollable descent and patient injury.

    Product
    Visaris Vision/Auto, ddRAura OTC APS, Diagnostic X-Ray System, Version 2.3 The Vision systems are intended for use in all areas of diagnostic radiography imaging and specifically at secondary and tertiary levels of medical care. Powerful positioning capability makes this system…
    Category
    Medical Device
    Distribution
    6 states