The Recall Desk

State

Louisiana product recalls

73,806 recalls have nationwide distribution and so reach Louisiana. 6,966 additional recalls listed Louisiana specifically in their distribution scope.

What the numbers show

Total
6,966
Critical
1,107
Severe
1,740
Most recent
2026-11-04

Of the 6,966 recalls naming Louisiana we have scored against our rubric, 1,107 (16%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,740 (25%) are Severe.

These figures cover only the 6,966 recalls whose distribution notice names Louisiana specifically. The 73,806 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

42076–42100 of 80772

  • SevereFDA (Devices)·Z-1815-2018·2018-05-23

    Medtronic Recalls Endo GIA Stapler Loading Units Due to Missing Sled Component

    Medtronic is recalling 171,271 Endo GIA Auto Suture Universal Articulating Loading Units because a missing sled component may prevent staple formation, leading to bleeding or leakage.

    Product
    Endo GIA" Auto Suture" Universal Articulating Loading Unit 30mm - 2.5mm ( Item Code 030451) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1863-2018·2018-05-23

    Medtronic Endo GIA Staplers Recalled for Missing Sled Component

    Medtronic is recalling Endo GIA universal staplers because a missing sled component may prevent staple formation, potentially causing bleeding or leakage.

    Product
    BOX VATS1SCDX DO ZABIEGOW VATS Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the staples is determined…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1862-2018·2018-05-23

    Medtronic Endo GIA Staplers Recalled for Missing Sled Component

    Medtronic is recalling Endo GIA universal staplers because a missing sled component may prevent staple formation, potentially causing bleeding or leakage.

    Product
    BOX TGGLOGOWX1 DO TOTAL GASTRECTOMIII Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the staples is…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1826-2018·2018-05-23

    Medtronic Endo GIA Universal Staplers Recalled for Missing Sled Component

    Medtronic is recalling 171,271 Endo GIA Universal and Universal XL staplers worldwide due to a missing sled component that may cause staple line failure, bleeding, or leakage.

    Product
    (1) BOX 01KBAR006116V PROC BYPASS 01KBAR0061(Item Code 01KBAR006116V PROC BYPAS) (2) BOX 1073076GASB0 BBR STVEIT GASTRIC B (Item Code BOX1073076GASB0) (3) BOX BOX1073076GASB0 BBR STVEIT GASTRIC B (Item Code BOX1073076GASB0 BBR STVEIT GASTRIC B) Product Usage…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1823-2018·2018-05-23

    Medtronic Endo GIA Vascular Reloads Recalled for Missing Sled Component

    Medtronic is recalling specific Endo GIA vascular reloads because a missing sled component may prevent staple formation, potentially causing bleeding or leakage.

    Product
    Endo GIA" 45mm Gray Curved Tip Articulating Vascular Reload with Tri-Staple" Technology( Item Code EGIA45CTAV) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1453-2018·2018-05-23

    eBars Recalls Trim Organic Chocolate Almond Bars for Peanut Allergen

    eBars is recalling Trim Organic Chocolate Almond bars because they tested positive for peanut, an allergen not declared on the label.

    Product
    TRIM ORGANIC CHOCOLATE ALMOND bar NET WT. 1.6 OZ (45g) Manufactured and Distributed by eBars, LLC, Franklin, TN 37064 UPC 8 55529 00423 0
    Category
    Food
    Distribution
    40 states
  • SevereFDA (Devices)·Z-1830-2018·2018-05-23

    COVIDIEN Medtronic Recalls Endo GIA Staplers for Missing Sled Component

    COVIDIEN Medtronic is recalling approximately 171,271 Endo GIA universal staplers because a missing sled component may prevent proper staple deployment. This defect can lead to bleeding or leakage of luminal contents during surgery.

    Product
    (1)BOX HEMIGX1 ZESTAW DO HEMICOLECTOMII (Item Number HEMIGX1 ZESTAW DO HEMICOLECTOMII) (2) BOX LAPPH ZASTAW DO PRAWEJ HEMIKOLEKTOMI (item number: LAPPH ZASTAW DO PRAWEJ HEMIKOLEKTOMI Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1455-2018·2018-05-23

    eBars Recalls Organic Dark Chocolate Berry Bars for Peanut Allergen

    eBars is recalling Woman Organic Dark Chocolate Berry bars because testing found undeclared peanut allergen. Consumers with peanut allergies should not eat the product.

    Product
    WOMAN ORGANIC DARK CHOCOLATE BERRY bar NET WT. 1.8 OZ (51g) Manufactured and Distributed by eBars, LLC, Franklin, TN 37064 UPC 8 55529 00418 9
    Category
    Food
    Distribution
    40 states
  • SevereFDA (Devices)·Z-1852-2018·2018-05-23

    Medtronic Endo GIA Staplers Recalled for Missing Sled Component

    Medtronic is recalling Endo GIA staplers because a missing sled component may prevent staple formation, leading to bleeding or leakage.

    Product
    BOX PST03533 KIT APP STAPLER Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the staples is determined by…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1816-2018·2018-05-23

    COVIDIEN Recalls Endo GIA Stapler Loading Units Due to Missing Sled Component

    COVIDIEN MEDTRONIC is recalling 171,271 Endo GIA Universal Articulating Loading Units because a missing sled component may prevent proper staple deployment, risking bleeding or leakage during surgery.

    Product
    Endo GIA" Auto Suture" Universal Articulating Loading Unit 30mm - 3.5mm ( Item Code 030452) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1824-2018·2018-05-23

    Medtronic Recalls Endo GIA Stapler Kits Due to Missing Sled Component

    Medtronic is recalling 171,271 Endo GIA stapler kits worldwide because a missing sled component may prevent staple formation, leading to bleeding or leakage.

    Product
    Covidien" Best Practices" Procedure Kits containing Auto Suture" Endo GIA" Devices Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1814-2018·2018-05-23

    Medtronic Recalls Endo GIA Stapler Loading Units Due to Missing Sled Component

    Medtronic is recalling 171,271 Endo GIA Auto Suture Universal Articulating Loading Units because a missing sled component may prevent staple formation, risking bleeding or leakage.

    Product
    Endo GIA" Auto Suture" Universal Articulating Loading Unit 30mm- 2.0mm ( Item Code 030450) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1847-2018·2018-05-23

    Medtronic Endo GIA Universal Staplers Recalled for Missing Sled Component

    Medtronic is recalling 169,775 Endo GIA Universal and Universal XL staplers worldwide and in the US because a missing sled component may prevent staple formation, risking bleeding or leakage.

    Product
    (1) BOX LAPZD ZESTAW DO SG (2) BOX LAPISG1 ZESTAW DO SG (3) BOX LAPISGW ZESTAW DO SG Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1843-2018·2018-05-23

    Medtronic Recalls Bariatric Surgical Kits Due to Missing Staple Sled Component

    Medtronic is recalling 169,775 bariatric surgical kits worldwide because a missing sled component may prevent staple formation, risking bleeding or leakage.

    Product
    (1)LAPBARLECZNA ZESTAW BARIATRYCZNY LECZNA (2) KITBAR021- BARIATRIC KIT X1 Item Code:KITBAR021- BARIATRIC KIT X0 (3)BOX SGGLOGX1 ZESTAW DO BARIATRII Item Code: SGGLOGX1 ZESTAW DO BARIATRII (4)BOX SGGLOGX1 ZESTAW DO BARIATRII Item Coder:SGGLOGX1 ZESTAW DO…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1454-2018·2018-05-23

    eBars Recalls Organic Dark Cocoa Raspberry Bars for Peanut Allergen

    eBars is recalling 26,180 units of TRIM Organic Dark Cocoa Raspberry bars because they tested positive for peanut, an allergen not declared on the label.

    Product
    TRIM ORGANIC DARK COCOA RASPBERRY bar NET WT. 1.8 OZ (51g) Manufactured and Distributed by eBars, LLC, Franklin, TN 37064 UPC 8 55529 00423 1
    Category
    Food
    Distribution
    40 states
  • SevereFDA (Devices)·Z-1840-2018·2018-05-23

    Medtronic Endo GIA Universal Staplers Recalled for Missing Sled Component

    Medtronic is recalling Endo GIA Universal and Universal XL staplers because a missing sled component may prevent staple formation, leading to bleeding or leakage.

    Product
    (1) BOX KITDE0143 BYPASS BOX (Item Number: KITDE0143, KITDE0143 BYPASS BOX) (2) BOX KITDE0154 BYPASS KH NORDWEST (Item Number: KITDE0154, KITDE0154 BYPASS KH NORDWEST Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1865-2018·2018-05-23

    Medtronic Endo GIA Staplers Recalled for Missing Sled Component

    Medtronic is recalling Endo GIA staplers because a missing sled component may prevent staple formation, potentially causing bleeding or leakage.

    Product
    BOX VMIN ZESTAW DO VATS PODSTAWOWY Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the staples is…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1452-2018·2018-05-23

    eBars Recalls Organic Dark Cocoa Raspberry Bars for Undeclared Peanut Allergen

    eBars is recalling 2,903 units of RUN Organic Dark Cocoa Raspberry bars because testing revealed the presence of peanut, an allergen not declared on the product label.

    Product
    RUN ORGANIC DARK COCOA RASPBERRY bar NET WT. 1.6 OZ (45g) Manufactured and Distributed by eBars, LLC, Franklin, TN 37064 UPC 8 55529 00412 7
    Category
    Food
    Distribution
    40 states
  • SevereFDA (Devices)·Z-1825-2018·2018-05-23

    Medtronic Endo GIA Universal Staplers Recalled for Missing Sled Component

    Medtronic is recalling Endo GIA Universal staplers because a missing sled component may prevent staple formation, leading to bleeding or leakage.

    Product
    BOX KIT1095V KIT OBESITAS (Item Code KIT1095V) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the staples…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1821-2018·2018-05-23

    Medtronic Recalls Endo GIA Stapler Reloads Due to Missing Sled Component

    Medtronic is recalling 171,271 Endo GIA 30mm stapler reloads because a missing sled component may prevent staple formation, potentially causing bleeding or leakage.

    Product
    Endo GIA" 30mm Gray Curved Tip Articulating Vascular Reload with Tri-Staple" Technology( Item Code EGIA30CTAV) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1447-2018·2018-05-23

    eBars Recalls Organic Chocolate Almond Bars Due to Peanut Allergen

    eBars is recalling GOLF Organic Chocolate Almonds bars because they tested positive for peanut, an undeclared allergen. The recall covers 5,391 bags distributed across 37 states.

    Product
    GOLF ORGANIC CHOCOLATE ALMONDS bar NET WT. 1.6 OZ (45g) Manufactured and Distributed by eBars, LLC, Franklin, TN 37064 UPC 8 55529 00400 4
    Category
    Food
    Distribution
    40 states
  • SevereFDA (Devices)·Z-1859-2018·2018-05-23

    Medtronic Endo GIA Stapler Sleeves Recalled for Missing Sled Component

    Medtronic is recalling 169,775 Endo GIA stapler sleeves worldwide due to a missing sled component that may prevent staple formation, risking bleeding or leakage.

    Product
    (1)BOX SLEEVEGK3 (2) BOX SLEEVEGK4 SLEEVE GASTRECTOMY (3)BOX SLEEVEJAWI SLEEVE GASTRECTOMY BOX (4) SSLEEVE ZEST DO SLEEVE GASTREKTOMIIX1 Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1817-2018·2018-05-23

    Medtronic Endo GIA Stapler Loading Units Recalled for Missing Sled Component

    Medtronic is recalling 171,271 Endo GIA Auto Suture Universal Articulating Loading Units because a missing sled component may prevent staple formation, risking bleeding or leakage.

    Product
    Endo GIA" Auto Suture" Universal Articulating Loading Unit 45mm - 2.5mm( Item Code 030454) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1828-2018·2018-05-23

    Medtronic Endo GIA Universal Staplers Recalled for Missing Sled Component

    Medtronic is recalling 171,271 Endo GIA Universal staplers because a missing sled component may prevent staple formation, risking bleeding or leakage.

    Product
    BOX1073076GASB1 BBR GASTRIC BYPASS S(Item Code BOX1073076GASB1 BBR GASTRIC BYPASS S) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1866-2018·2018-05-23

    Medtronic Endo GIA Staplers Recalled for Missing Sled Component

    Medtronic is recalling Endo GIA universal staplers because a missing sled component may prevent staple formation, potentially causing bleeding or leakage.

    Product
    BOX VWR ZESTAW DO VATS KLIN Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the staples is determined by…
    Category
    Medical Device
    Distribution
    Distributed nationwide