  • SevereFDA (Food)·F-0800-2013·2012-12-12

    Boulder Ice Cream Recalls Serano Gelato Chocolate Peanut Butter for Salmonella Risk

    Boulder Ice Cream is recalling Serano Gelato Chocolate Peanut Butter due to potential Salmonella contamination from peanut ingredients.

    Product
    Serano Gelato Chocolate Peanut Butter, 16 oz, contained in a semiflexible paper container, manufactured by Fresca Foods, CO.
    Category
    Food
    Distribution
    25 states
  • SevereNHTSA·12V581000·2012-12-12

    Can-Am Spyder GS and RS Fuel Vapor Hose Recall

    Bombardier is recalling 2008-2010 Can-Am Spyder GS and RS vehicles because fuel vapors may exit the engine compartment, posing a fire risk.

    Product
    CAN-AM — CAN-AM SPYDER GS, SPYDER RS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-0741-2013·2012-12-12

    Omya Recalls Food Grade Ground Limestone Due to Salmonella Risk

    Omya Inc. is voluntarily recalling specific lots of food grade ground limestone processed in Arizona due to the possible presence of Salmonella.

    Product
    Ground limestone also known as calcium carbonate. Omya's food grade ground limestone products. All bulk with no product labeling. Product Container Size Omya-Cal FG-10 AZ 50 lb. bags 2500 lb. bulk bags…
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-089-2013·2012-12-12

    Caraco Recalls Tramadol Tablets Due to Foreign Metoprolol Contamination

    Caraco is recalling Tramadol HCl 50 mg tablets because a customer reported finding Metoprolol Tartrate tablets in a bottle.

    Product
    traMADOL Hydrochloride Tablets, USP 50 mg, 1000-count tablets per bottle, Manufactured by: Sun Pharmaceuticals Industries, Dadra 396 191, India; Distributed by: Caraco Pharmaceutical Laboratories, Ltd., 1150 Elijah McCoy Drive, Detroit, MI 48202; NDC 57664-377-18.
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0447-2013·2012-12-12

    Natus Olympic Cool-Cap Recalled Due to Frozen Screen Malfunction

    Natus Medical is recalling 324 Olympic Cool-Cap systems because the control module screen may freeze, causing the device to stop cooling infants without visible alarm.

    Product
    The product has the Catalogue/Part number 60010. Olympic Cool-Cap System is a selective head cooling system for treatment of hypoxic-ischemic encephalopathy (HIE) in infants. A cooling water cap is placed on the infant's head and the body is warmed using radiant warmers.…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-0799-2013·2012-12-12

    Boulder Ice Cream Recalls Organic Gelato Due to Salmonella Risk

    Boulder Ice Cream is recalling Organic Gelato Chocolate Peanut Butter due to potential Salmonella contamination from peanut ingredients.

    Product
    Organic Gelato Chocolate Peanut Butter, 5 liter, contained in plastic packaging, manufactured by Fresca Foods, CO.
    Category
    Food
    Distribution
    25 states
  • HighFDA (Devices)·Z-0471-2013·2012-12-12

    Biomet Recalls OSS Knee Reamer Sleeves Due to Sticking Risk

    Biomet is recalling 46 OSS Knee Reamer Sleeves because the thin shaft reamer may get stuck and fail to slide into the sleeve.

    Product
    OSS Reamer Sleeve REF132-472661 KNEE REAMER SLEEVE 8.0 THRU 12.5 STAINLESS STEEL The OSS Knee Reamer Sleeves are primarily used to guide the bullet tip of cylindrical reamers during the tibial preparation in OSS procedures. They are reusable.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0457-2013·2012-12-12

    Terumo Recalls Sarns Aortic Cannulas Due to Plastic Flash Defect

    Terumo is recalling Sarns Soft-Flow Aortic Cannulas because plastic flash at the tip may detach and cause adverse patient effects.

    Product
    24 Fr 8mm Sft Flow Straight Wir The Sarns Aortic Cannula is indicated for use in perfusion of the ascending aorta during cardiopulmonary bypass surgery. These devices are indicated for up to 6 hours of use
    Category
    Medical Device
    Distribution
    27 states
  • HighFDA (Devices)·Z-0462-2013·2012-12-12

    Terumo Recalls Sarns Aortic Cannulas Due to Plastic Flash Defect

    Terumo is recalling Sarns Aortic Cannulas because plastic flash at the tip may detach and harm patients during surgery.

    Product
    24 Fr 8mm Soft Flow Ang W/L The Sarns Aortic Cannula is indicated for use in perfusion of the ascending aorta during cardiopulmonary bypass surgery. These devices are indicated for up to 6 hours of use.
    Category
    Medical Device
    Distribution
    27 states
  • HighFDA (Devices)·Z-0458-2013·2012-12-12

    Terumo Recalls Sarns Aortic Cannulas Due to Plastic Flash Defect

    Terumo is recalling Sarns Aortic Cannulas because plastic flash at the tip could detach and harm patients during surgery.

    Product
    24 Fr 8mm Sft Flow Straight The Sarns Aortic Cannula is indicated for use in perfusion of the ascending aorta during cardiopulmonary bypass surgery. These devices are indicated for up to 6 hours of use.
    Category
    Medical Device
    Distribution
    27 states
  • HighFDA (Devices)·Z-0464-2013·2012-12-12

    Merit Medical Systems Recalls Custom Procedural Trays Due to Missing Tape

    Merit Medical Systems is recalling 83 custom procedural trays because clear protective tape was not applied during manufacturing.

    Product
    Custom Procedural Trays: Merit's Custom Total Hip Pack, K12T-05537, Merit's Total Knee Pack, K12T05538 A custom procedural tray is a combination of legally marketed medical devices placed into one container for the convenience of the user and used within the limits of the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0475-2013·2012-12-12

    Philips Digital Diagnost Software Recall for Image Marker Error

    Philips is recalling Digital Diagnost Software R2.0.2 because a mirrored image marker can be mistaken for a patient side indicator.

    Product
    Philips Digital Diagnost Software Version R2.0.2 Product Usage: This system is used for making X-ray exposures for diagnostics
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0472-2013·2012-12-12

    Biomet Recalls OSS Knee Reamer Sleeves Due to Sticking Defect

    Biomet is recalling 36 OSS Knee Reamer Sleeves because the thin shaft reamer may get stuck and fail to slide into the sleeve.

    Product
    OSS Reamer Sleeve REF132-472662 KNEE REAMER SLEEVE 13.0 thru 20.0 STAINLESS STEEL The OSS Knee Reamer Sleeves are primarily used to guide the bullet tip of cylindrical reamers during the tibial preparation in OSS procedures. They are reusable.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0455-2013·2012-12-12

    Stryker Neptune 2 Rover Recall Due to Binding Casters

    Stryker is recalling 154 Neptune 2 Rover units because a castor design defect can cause binding, leading to operator strain and back pain.

    Product
    Neptune¿ 2 Rover - ULTRA ~230V ~ 50 Hz 12A REF 0702-002-000, Rx Caution, consult accompanying documents Consult instructions for use, Max Vacuum; 21.0 in-Hg, 530 mm-Hg, The Neptune Waste Management System consists of a mobile rover unit used to suction and collect fluid…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0474-2013·2012-12-12

    Biomet Recalls Bio-Modular Humeral Heads Due to Missing Ion Implantation

    Biomet, Inc. is recalling four Bio-Modular Humeral Heads because they are missing the ion implantation feature, which may cause increased wear and shorter implant life.

    Product
    Bio-Modular Humeral Head 48mm x 24mm Ti 6AI4V/Ion Implanted (Orthopedic Implant) Product Usage: The OSS Knee Reamer Sleeves are primarily used to guide the bullet tip of cylindrical reamers during the tibial preparation in OSS procedures. They are reusable.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·12V582000·2012-12-12

    Can-Am Spyder Fuel Cap Recall Due to Fire Risk

    Bombardier is recalling 2008-2012 Can-Am Spyder vehicles because the fuel cap may not seal properly, creating a fire hazard.

    Product
    CAN-AM — CAN-AM SPYDER RS, SPYDER RT, SPYDER GS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0452-2013·2012-12-12

    Siemens IRON Flex Reagent Cartridges Recalled for Falsely Elevated Results

    Siemens Healthcare Diagnostics is recalling IRON Flex reagent cartridges because environmental iron contamination can cause falsely elevated test results.

    Product
    Dimension Vista(R) IRON Flex(R) reagent cartridge (K3085) The IRON method is an in vitro diagnostic test for the quantitative determination of iron in human serum and plasma on the Dimension Vista(R) System. Measurements of iron are used in the diagnosis and treatment of…
    Category
    Medical Device
    Distribution
    46 states
  • HighFDA (Devices)·Z-0466-2013·2012-12-12

    Philips and Neusoft Recall CT Scanners Due to Detaching Patient Table

    Philips and Neusoft are recalling 45 CT scanners because the patient table top can detach from the carrier, posing a risk of injury.

    Product
    NeuViz 16 Multi-Sliced CT Scanner System, part number 989605858501. NeuViz Dual series CT Scanner System, part number 989605651321 The NeuViz 16 CT Scanner System can be used as a whole body computed tomography X-ray system featuring a continuously rotating X-ray tube and…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0468-2013·2012-12-12

    Invivo Expression MRI Patient Monitoring System Recalled for Detached Caster Risk

    Invivo Corporation is recalling the Expression MRI Patient Monitoring System because a caster may detach during transport, causing the cart to fall.

    Product
    Invivo Corporation Expression MRI Patient Monitoring System. The Expression MRI Patient Monitoring System is intended for use by healthcare professionals to monitor vital signs for patients undergoing MRI procedures. The Patient Monitoring System also provides signals for…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0453-2013·2012-12-12

    OmniGuide BP-ROBOTIC Fiber Recalled Due to Glue Joint Failure

    OmniGuide, Inc. is recalling 45 units of BP-ROBOTIC single-use fibers because a glue joint failure may cause the device to shift and fall into the patient.

    Product
    OmniGuide BP-ROBOTIC ( BeamPath Robotic), Single Use Cat. # BP-ROBOTIC The OmniGuide Fiber is indicated for the incision, excision, ablation, vaporization and coagulation of body soft tissues including intra-oral tissues. It is indicated in the medical specialties of general…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0459-2013·2012-12-12

    Terumo Recalls Sarns Aortic Cannulas Due to Plastic Flash Defect

    Terumo is recalling Sarns Soft-Flow Aortic Cannulas because plastic flash at the tip may detach and cause adverse patient effects.

    Product
    18 Fr 6mm Sft Flow Angled Wire The Sarns Aortic Cannula is indicated for use in perfusion of the ascending aorta during cardiopulmonary bypass surgery. These devices are indicated for up to 6 hours of use.
    Category
    Medical Device
    Distribution
    27 states
  • HighFDA (Devices)·Z-0461-2013·2012-12-12

    Terumo Recalls Sarns Aortic Cannulas Due to Plastic Flash Defect

    Terumo is recalling Sarns Aortic Cannulas because plastic flash at the tip may detach and harm patients during surgery.

    Product
    24 Fr 8mm Soft Flow Ang Wire W/L The Sarns Aortic Cannula is indicated for use in perfusion of the ascending aorta during cardiopulmonary bypass surgery. These devices are indicated for up to 6 hours of use.
    Category
    Medical Device
    Distribution
    27 states
  • HighFDA (Devices)·Z-0460-2013·2012-12-12

    Terumo Recalls Sarns Soft-Flow Aortic Cannulas Due to Plastic Flash

    Terumo is recalling Sarns Soft-Flow Aortic Cannulas because plastic flash at the tip may detach and cause adverse patient effects.

    Product
    18 Fr 6mm Sft Flow Ang Wire W/L The Sarns Aortic Cannula is indicated for use in perfusion of the ascending aorta during cardiopulmonary bypass surgery. These devices are indicated for up to 6 hours of use.
    Category
    Medical Device
    Distribution
    27 states
  • HighFDA (Devices)·Z-0456-2013·2012-12-12

    Terumo Recalls Sarns Aortic Cannulas Due to Plastic Flash Defect

    Terumo is recalling Sarns Soft-Flow Aortic Cannulas because plastic flash at the tip may detach and cause adverse patient effects.

    Product
    24 Fr 8mm Sft Flow Str Wire W/L The Sarns Aortic Cannula is indicated for use in perfusion of the ascending aorta during cardiopulmonary bypass surgery. These devices are indicated for up to 6 hours of use.
    Category
    Medical Device
    Distribution
    27 states