The Recall Desk

State

Indiana product recalls

73,824 recalls have nationwide distribution and so reach Indiana. 9,598 additional recalls listed Indiana specifically in their distribution scope.

What the numbers show

Total
9,598
Critical
1,908
Severe
2,536
Most recent
2026-11-04

Of the 9,598 recalls naming Indiana we have scored against our rubric, 1,908 (20%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 2,536 (26%) are Severe.

These figures cover only the 9,598 recalls whose distribution notice names Indiana specifically. The 73,824 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

49776–49800 of 83422

  • HighNHTSA·17V176000·2017-03-14

    Mercedes-Benz Recalls 2017 E300 Models for Front Passenger Air Bag Defect

    Mercedes-Benz is recalling 2017 E300 and E300 4Matic vehicles because the front passenger air bag may not deploy properly in certain seating positions, increasing injury risk.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ E300
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17V160000·2017-03-13

    Spartan Trucks Recalled for Front Suspension Ball Joint Separation Risk

    Spartan Motors is recalling specific 2011-2018 trucks because front suspension ball joints can loosen, potentially causing a loss of steering control.

    Product
    SPARTAN — SPARTAN K4, METROSTAR, K3, K2
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17V168000·2017-03-13

    Ford Recalls 2017 Mustangs for Door Handle Spring Defect

    Ford is recalling 2017 Mustangs because the driver-side door handle spring may loosen, allowing the door to unlatch in a crash.

    Product
    FORD — FORD MUSTANG
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17V170000·2017-03-13

    Roush-Modified Ford Propane Vehicles Recalled for Fuel Valve Defect

    Roush CleanTech is recalling 2015-2017 modified Ford E-450, F59, F-650, and F-750 vehicles because a fuel control valve solenoid may short circuit, causing the engine to shut off while driving.

    Product
    FORD — FORD F-650 ROUSH PROPANE, F-750 ROUSH PROPANE, F59 ROUSH PROPANE, E-450 ROUSH PROPANE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17E017000·2017-03-13

    Roush Propane Conversion Kit Recall for Fuel Valve Short Circuit

    Roush CleanTech is recalling Generation 4 Propane Conversion Kits because a fuel control valve solenoid may short circuit, causing the engine to shut off while driving.

    Product
    FUEL SYSTEM, OTHER recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17V161000·2017-03-13

    Maserati Recalls 2017 Levante Models Due to Engine Software Defect

    Maserati is recalling 2017 Levante vehicles because an engine software issue may cause the transmission to shift into neutral or the engine to shut off at slow speeds.

    Product
    MASERATI — MASERATI LEVANTE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·17V162000·2017-03-13

    Thor Motor Coach Recalls 2014-2016 Motorhomes for Wiper Defect

    Thor Motor Coach is recalling specific 2014-2016 motorhomes because improperly installed windshield wipers may fail, impairing visibility and increasing crash risk.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH, THOR MOTOR DAYBREAK, ACE, CHALLENGER, WINDSPORT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·17V165000·2017-03-13

    Ride The Ducks Recalls Amphibious Vehicles for Instrument Cluster Defect

    Ride The Ducks International LLC is recalling 1996-2014 amphibious vehicles because the instrument cluster fails to properly illuminate turn signal and high beam indicators, potentially increasing crash risk.

    Product
    RIDE THE DUCKS — RIDE THE DUCKS AMPHIBIOUS VEHICLE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·17V166000·2017-03-13

    Thor Motor Coach Recalls 2017 Motorhomes Due to Missing Seat Belts

    Thor Motor Coach is recalling 2017 Chateau, Freedom Elite, and Four Winds motorhomes because the middle sofa seat may lack a seat belt, increasing crash injury risk.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH FREEDOM ELITE, FOUR WINDS, CHATEAU
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17V158000·2017-03-10

    Polaris Recalls 2017 Slingshot Models for Steering Bolt Tightening Defect

    Polaris is recalling 2017 Slingshot, SL, and SLR vehicles because three steering and suspension bolts may be insufficiently tightened, potentially reducing vehicle handling.

    Product
    POLARIS — POLARIS SLINGSHOT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·17V159000·2017-03-10

    Kia Recalls 2017 Niro Hybrid for Power Steering Connector Defect

    Kia is recalling 2017 Niro Hybrid vehicles because a damaged steering connector may cause a loss of power steering assist, increasing the risk of a crash.

    Product
    KIA — KIA NIRO HYBRID
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·17108·2017-03-10

    R.W. Beckett Recalls Firomatic Fuel Oil Valves Due to Fire Hazard

    R.W. Beckett is recalling approximately 18,000 Firomatic fusible safety valves because the stem may fail to seal, allowing fuel to leak and posing a fire hazard.

    Product
    Firomatic® fusible safety valves
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·17V154000·2017-03-09

    Land Rover Recalls 2016 Range Rovers for Passenger Air Bag Defect

    Jaguar Land Rover is recalling 2016 Range Rover and Range Rover Sport vehicles because the passenger air bag inflator may fail to ignite, preventing deployment in a crash.

    Product
    LAND ROVER — LAND ROVER RANGE ROVER, RANGE ROVER SPORT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereUSDA FSIS·023-2017·2017-03-09

    King's Command Foods Recalls Beef Products Due to Foreign Matter

    King's Command Foods is recalling approximately 26,138 pounds of ground beef products due to possible contamination with extraneous materials, including metal objects.

    Product
    King's Command Foods, LLC — King's Command Foods, LLC. Recalls Beef Products Due To Possible Foreign Matter Contamination
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereNHTSA·17V153000·2017-03-09

    Jaguar Recalls 2017 F-PACE Vehicles Due to Short Rear Driveshaft

    Jaguar is recalling 2017 F-PACE vehicles with automatic transmissions because a short rear driveshaft may separate, causing loss of drive power and increasing crash risk.

    Product
    JAGUAR — JAGUAR F-PACE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17V155000·2017-03-09

    Airstream Recalls 2017 Base Camp Trailers Due to Tire Contact Risk

    Airstream is recalling 2017 Base Camp recreational trailers because heavy loads may cause tires to contact the wheel well liner, risking tire failure and crashes.

    Product
    AIRSTREAM — AIRSTREAM BASECAMP
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17V156000·2017-03-09

    Gillig Recalls 2016-2017 Low Floor Buses for Wiper Arm Defect

    Gillig is recalling 2,732 Low Floor transit buses because wiper arms can crack and detach, reducing driver visibility and increasing crash risk.

    Product
    GILLIG — GILLIG LOW FLOOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·17107·2017-03-09

    Pier 1 Imports Recalls Bistro Chairs Due to Fall Hazard

    Pier 1 Imports is recalling Neely and Dahlia bistro chairs because loose bolts can cause the legs to collapse, posing a fall hazard.

    Product
    Neely and Dahlia Bistro Chairs
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·17V157000·2017-03-09

    Manac Recalls 2016-2017 Van Trailers Due to Failing Rub Rail Rivets

    Manac is recalling 2016-2017 Van Trailers because aluminum rivets securing external rub rails may fail, allowing the rails to detach and become road hazards.

    Product
    MANAC — MANAC VAN TRAILER
    Category
    Vehicle
    Distribution
    Distributed nationwide