1201–1225 of 85249

  • HighFDA (Devices)·Z-2841-2026·2026-08-12

    Powered wheelchair controller recalled for unexpected braking hazard

    Pride Mobility Products Corp. is recalling 1,102 Quantum 4Front 2 wheelchair controllers because reminder pop-ups can trigger unexpected park brake stops while driving, causing falls or injuries.

    Product
    Brand Name: Quantum Rehab Product Name: Quantum 4Front 2 Model/Catalog Number: Quantum 4Front 2 Software Version: 2.0.11, new version: 2.0.13 Product Description: Wheelchair, Powered (ITI), 890.3860 Component: Controller
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2884-2026·2026-08-12

    USTAR II Knee System Hinge Box Trial Recall

    United Orthopedic Corp. is recalling USTAR II Knee System Hinge Box Trials due to a manufacturing defect that could prevent proper assembly of the stem trial component.

    Product
    Brand Name: USTAR II Knee System Product Name: Hinge Box Trial, L, #1-6 and Hinge Box Trial, R, #1-6 Model/Catalog Number: 9325-5711 thru 9325-5716 and 9325-5721 thru 9325-5726 Software Version: N/A Product Description: Knee femur prosthesis trial, reusable Component: No…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2859-2026·2026-08-12

    Anti-Torque Instrument in Vector Pedicle Screw System Recalled

    Innovasis, Inc is recalling 5 Anti-Torque instruments (part LS-749) in the Vector Pedicle Screw System due to an undersized condition that may prevent proper engagement during spinal surgery, causing delays.

    Product
    Anti-Torque, Vector, Part: LS-749 part of Vector Pedicle Screw System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2837-2026·2026-08-12

    Integrated Medcraft Recalls First Aid Kits with Defective Airway Tips

    Integrated Medcraft is recalling specific Kingfisher Compact Individual First Aid Kits because the included Guedel airway components may have occluded tips.

    Product
    Kingfisher Compact Individual First Aid Kit. REF Number: 76656. Containing the affected One-piece Guedel airway components: 1. Size 00, ISO 5.0, blue. Product Code: 1100050. 2. Size 000, ISO 3.5, light green. Product Code: 1000035.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2904-2026·2026-08-12

    Tissium COAPTIUM CONNECT Nerve Repair Device Shelf Life Recall

    Tissium SA is recalling the COAPTIUM CONNECT peripheral nerve repair device because the labeled 36-month shelf life is not supported by real-time data; the validated shelf life is 26 months.

    Product
    Brand Name: COAPTIUM CONNECT Product Name: COAPTIUM CONNECT Model/Catalog Number: NCOCO2075 Software Version: N/A Product Description: In situ polymerizing peripheral nerve repair device Component: No
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2860-2026·2026-08-12

    Flow Anesthesia Machines Recalled for Failure to Deliver Anesthetic Agent

    The FDA is recalling Flow Anesthesia Machines because events occurred where the anesthetic agent was not delivered when the vaporizer was activated, potentially causing patients to receive insufficient anesthesia.

    Product
    Flow Anesthesia Machine Flow-i C20 6677200 Flow-i C30 6677300 Flow-i C40 6677400 Flow-i C20 6888520 Flow-i C30 6888530 Flow-i C40 6888540 Flow-c 6887700 Flow-e 6887900
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2883-2026·2026-08-12

    Knee Prosthesis Trial Recall for Manufacturing Defect

    United Orthopedic Corp. recalls U2 Total Knee System PSA Box Trial due to a manufacturing defect in a component screw that prevents proper assembly of the stem trial.

    Product
    Brand Name: U2 Total Knee System Product Name: PSA Box Trial, L, #1-6 and PSA Box Trial, R, #1-6 Model/Catalog Number: 9323-5511 thru 9323-5516 and 9323-5521 thru 9323-5526 Software Version: N/A Product Description: Knee femur prosthesis trial, reusable Component: No, N/A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2890-2026·2026-08-12

    Siemens Atellica CH Urine Albumin In Vitro Diagnostic Recall

    Siemens Healthcare Diagnostics is recalling Atellica CH Urine Albumin assays due to potential false results and QC failures when processed on CI analyzers.

    Product
    Atellica CH Urine Albumin REF: 11537225, in vitro diagnostic
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2911-2026·2026-08-12

    Neuroguard IEP Carotid Stent and Balloon System Recalled for Filter Failure Risk

    Contego Medical, Inc is recalling Neuroguard IEP Carotid Stent and Post-Dilation Balloon Systems due to a potential filter failure issue.

    Product
    Neuroguard IEP 3 in 1 Carotid Stent and Post-Dilation Balloon System with Integrated Embolic Protection (Neuroguard IEP System), REF: NG-0630-140-2, NG-0640-140-2, NG-0730-140-2, NG-0740-140-2, NG-NV-6-30, NG-NV-6-40, NG-NV-7-30, NG-NV-7-40
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2892-2026·2026-08-12

    Philips Azurion interventional fluoroscopic X-ray systems recalled for potential hardware failures

    Philips Azurion X-ray systems may lose imaging capability or motor functions due to unauthorized hard drives.

    Product
    Philips Azurion under the following System Descriptions and corresponding model numbers: 1. Azurion 3 M12; Model Numbers: 722063, 722221. 2. Azurion 3 M15; Model Numbers: 722064, 722222, 722280. 3. Azurion 5 M12; Model Number: 722227. 4. Azurion 5 M20; Model Numbers…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2864-2026·2026-08-12

    Stryker Recalls Ahto Dual Spike Tube Set Due to Leaking Handpiece

    Stryker Corporation is recalling 2,739 units of the Ahto Dual Spike Tube Set packaging due to reported handpiece leaks during use. No injuries have been reported.

    Product
    STRYKER AHTO DUAL SPIKE TUBE SET PACKAGING, Catalog Number 0250070640
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2878-2026·2026-08-12

    GE Healthcare Portrait Core Services Software Recall Due to Software Vulnerability

    GE Medical Systems Information Technologies Inc is recalling GE Healthcare Portrait Core Services SW V 1.2.0 (REF 5700592) patient monitoring systems due to a software vulnerability.

    Product
    GE Healthcare Portrait Core Services SW V 1.2.0, REF 5700592. patient monitoring system
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·26E055000·2026-08-12

    Mack Recalls Grote Replacement Marker Lights for Visibility Failure

    Mack Trucks is recalling certain Grote replacement marker lights that may fail to illuminate, reducing vehicle visibility and increasing crash risk.

    Product
    GROTE — GROTE CLEARANCE/MARKER LAMP
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2858-2026·2026-08-12

    Medical Action Industries Recalls Dialysis Change Tray Kits Due to Seal Defect

    Medical Action Industries is recalling 3,740 Dialysis Change Tray Clear Sequence kits because the needle-free access device may have an improper seal.

    Product
    Brand Name: Medical Action Industries Product Name: Dialysis Change Tray Clear Sequence Model/Catalog Number: 78791
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2874-2026·2026-08-12

    Merge PACS Medical Imaging Workstation Recalled Due to Patient Data Display Error

    Merge Healthcare is recalling 53 Merge PACS medical imaging workstations due to a software issue where thumbnails from one patient's study may incorrectly display when viewing a different patient's study, potentially compromising patient confidentiality.

    Product
    Merge PACS, medical imaging diagnostic workstation
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2836-2026·2026-08-12

    FORWARD Oral Airway Kit Recall for Potential Airway Obstruction

    Integrated Medcraft LLC recalls FORWARD Oral Airway Kits due to potential occlusion of the airway tip, which could impede breathing in medical settings.

    Product
    FORWARD Oral Airway Kit (OPA Sizes 5, 6.5, 7, 8, 9, 10, 12). REF Number: 1011-40002. Containing the affected One-piece Guedel airway components: 1. Size 00, ISO 5.0, blue. Product Code: 1100050. 2. Size 000, ISO 3.5, light green. Product Code: 1000035.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2902-2026·2026-08-12

    Peripheral Nerve Repair Device Relabeled Due to Unsubstantiated Shelf Life

    Tissium SA is relabeling COAPTIUM CONNECT nerve repair devices because the 36-month shelf life is not supported by real-time data. The revised shelf life is 26 months.

    Product
    Brand Name: COAPTIUM CONNECT Product Name: COAPTIUM CONNECT Model/Catalog Number: NCOCO1575 Software Version: N/A Product Description: In situ polymerizing peripheral nerve repair device Component: No
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2899-2026·2026-08-12

    GEM Premier 7000 with iQM3 Blood Analysis Systems Recalled for Solution Concentration Issues

    Instrumentation Laboratory is recalling specific GEM Premier 7000 with iQM3 PAK lots because the lysing bag solution concentration does not meet manufacturing specifications, potentially delaying medical management.

    Product
    GEM Premier 7000 with iQM3 Part Numbers: 00077407508 00077407510 00077415004 00077415008 00077415010 00077430010 Product Description: The GEM Premier 7000 with iQM3 is a portable critical care system for use by health care professionals to rapidly analyze lithium…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2901-2026·2026-08-12

    COAPTIUM Connect Nerve Repair Device Relabeled Due to Unsubstantiated Shelf Life

    Tissium SA is relabeling COAPTIUM Connect nerve repair devices to reduce the shelf life from 36 to 26 months because the original duration was not supported by real-time data.

    Product
    Brand Name: COAPTIUM Connect Product Name: COAPTIUM Connect Model/Catalog Number: NCOCO1510 Software Version: N/A Product Description: In situ polymerizing peripheral nerve repair device Component: N/A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2885-2026·2026-08-12

    U2 Total Knee System Femoral Valgus Adaptor Recall

    United Orthopedic Corp. is recalling its U2 Total Knee System femoral valgus adaptors due to a manufacturing defect that prevents proper assembly of the stem component during surgery.

    Product
    Brand Name: U2 Total Knee System Product Name: Femoral valgus adaptor, left and right Model/Catalog Number: 9323-5333 and 9323-5334 Software Version: N/A Product Description: Manual Orthopedic Surgical Instrument Component: No
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2844-2026·2026-08-12

    Quantum Rehab R-TRAK Powered Wheelchair Controller Recalled Due to Software Issue

    Pride Mobility Products Corp. is recalling Quantum Rehab R-TRAK powered wheelchairs due to a software issue that can cause unexpected braking or system crashes.

    Product
    Brand Name: Quantum Rehab Product Name: R-TRAK Model/Catalog Number: R-TRAK Software Version: 2.0.11, new version: 2.0.13 Product Description: Wheelchair, Powered (ITI), 890.3860 Component: Controller
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2893-2026·2026-08-12

    Philips Fluoroscopy System Recall Over Hard Disk Drive Issue

    Philips is recalling 257 Allura/Centron interventional fluoroscopic X-ray systems due to potential loss of imaging, motorized movement, or data caused by unauthorized hard disk drives.

    Product
    Philips Allura, Cardio Vascular-Allura Centron. Model Number: 722400. Interventional Fluoroscopic X-Ray System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2848-2026·2026-08-12

    Quantum Rehab Q6 Edge 2.0 Wheelchair Recall Due to Safety Risks

    The FDA is recalling the Quantum Rehab Q6 Edge 2.0 powered wheelchair because its controller may cause unexpected braking or system crashes that could lead to falls and injuries.

    Product
    Brand Name: Quantum Rehab Product Name: Q6 Edge 2.0 (ilevel) Model/Catalog Number: Q6 Edge 2.0 (ilevel) Software Version: 2.0.11, new version: 2.0.13 Product Description: Wheelchair, Powered (ITI), 890.3860 Component: Controller
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2894-2026·2026-08-12

    5-PLASMA Bivalirudin AMR Verification Kit Recalled Due to Stability Issues

    Aniara Diagnostica LLC recalls its 5-PLASMA Bivalirudin AMR Verification Kit due to stability issues causing degradation of measurable bivalirudin in controls, calibrators, and linearity values. FDA Class II recall.

    Product
    5-PLASMA Bivalirudin AMR Verification Kit, Model Number 5D-45905
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2903-2026·2026-08-12

    Tissium Peripheral Nerve Repair Device Shelf Life Recall

    Tissium SA is recalling the COAPTIUM CONNECT peripheral nerve repair device due to an unsubstantiated 36-month shelf life; devices will be relabeled to a validated 26-month shelf life.

    Product
    Brand Name: COAPTIUM CONNECT Product Name: COAPTIUM CONNECT Model/Catalog Number: NCOCO2010 Software Version: N/A Product Description: In situ polymerizing peripheral nerve repair device Component: No
    Category
    Medical Device
    Distribution
    Distributed nationwide