24976–25000 of 85228

  • HighFDA (Devices)·Z-0616-2022·2022-02-16

    GE Healthcare MR Superconducting Magnets Cryogen Ventilation System Defect

    GE Healthcare is recalling 17,228 superconducting magnetic resonance imaging systems due to potential cryogen ventilation system defects that may not meet safety venting requirements.

    Product
    GE Healthcare MR superconducting magnets, a component of GE Healthcare Contour System, nuclear magnetic resonance imaging system.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·22V081000·2022-02-16

    Lamborghini Recalls Huracan Models Due to Missing Headlight Adjustment Caps

    Lamborghini is recalling 2015-2020 Huracan vehicles because missing caps on headlight adjustment screws can lead to improper alignment, reducing visibility and increasing crash risk.

    Product
    LAMBORGHINI — LAMBORGHINI HURACAN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0567-2022·2022-02-16

    Dunnage Case Shipped Instead of THERAKOS CELLEX Photopheresis Kits

    A dunnage case containing sterilization packaging was shipped in place of THERAKOS CELLEX Photopheresis Procedural Kits. The material is not intended for customer use and should not be used.

    Product
    THERAKOS CELLEX Photopheresis Procedural Kit, CLXUSA
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0582-2022·2022-02-16

    Medical device reference standard contaminated with bacterial species

    Microbiologics recalls KWIK-STIK Streptococcus pneumoniae reference standards due to potential contamination with Staphylococcus epidermidis, E. coli, and Staphylococcus warneri affecting 271 units worldwide.

    Product
    KWIK-STIK(TM), Streptococcus pneumoniae derived from ATCC(R) 49619(TM), packaged as follows: a. KWIK-STIK(TM) 2 Pack; b. KWIK-STIK(TM) 6 Pack. Each KWIK-STIK unit contains a lyophilized microorganism pellet, an ampoule of hydrating fluid, and an inoculating swab.…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateCPSC·22084·2022-02-16

    Scarves Recalled for Flammability Standard Violation and Burn Risk

    In-Things Corporation is recalling about 200 "Sparkle Sheer Social Wrap" scarves sold online because they fail to meet federal flammability standards for textiles, posing a burn injury risk.

    Product
    Scarves
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • ModerateCPSC·22085·2022-02-16

    Anecdote Autumn Glass Candles recalled for fire and laceration hazards

    Anecdote Candles is recalling approximately 19,380 Autumn Glass Candles sold at Anthropologie because the double-wick candles can produce higher-than-normal flames, causing the glass container to break and posing fire and laceration hazards.

    Product
    Anecdote Autumn Glass Candles
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0621-2022·2022-02-16

    GE Healthcare MRI Superconducting Magnet Cryogen Ventilation System Defect

    GE Healthcare is recalling 17,228 MRI superconducting magnets due to a potential cryogen ventilation system defect. The systems may not meet required venting specifications.

    Product
    GE Healthcare MR superconducting magnets, a component of GE Healthcare Orthone (1.0T MSK Extreme) System, nuclear magnetic resonance imaging system.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·22V080000·2022-02-15

    Land Rover Recalls 2020 Range Rover Evoque for SRS Warning Light Software Defect

    Jaguar Land Rover is recalling 2020 Range Rover Evoque vehicles because incorrect software may cause the airbag warning light to malfunction, potentially masking actual system failures.

    Product
    LAND ROVER — LAND ROVER RANGE ROVER EVOQUE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22E007000·2022-02-14

    Weldon recalls rear combination lamps with incorrect white backup lights

    Weldon is recalling specific rear combination lamps because the LED backup lights are the wrong color, failing federal safety standards and potentially affecting vehicle visibility.

    Product
    EXTERIOR LIGHTING:BACK UP LIGHTS recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V077000·2022-02-11

    Chrysler Recalls 2017-2018 Pacifica Plug-In Hybrids for Fire Risk

    Chrysler is recalling 2017-2018 Pacifica Plug-In Hybrid vehicles because a fire can occur while parked. Owners should park outside and avoid recharging until repairs are completed.

    Product
    CHRYSLER — CHRYSLER PACIFICA PLUG-IN HYBRID
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V078000·2022-02-11

    Mercedes-Benz Recalls 2021 GLB 250 Vehicles for Front Air Bag Defect

    Mercedes-Benz is recalling 2021 GLB 250 vehicles because an incorrect front driver's air bag module may not restrain occupants or could detach during a crash.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ GLB 250
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·22721·2022-02-10

    2022 Can-Am Outlander ATVs Recalled Due to Speedometer Crash Hazard

    BRP U.S. Inc. is recalling about 1,300 2022 Can-Am Outlander ATVs because the speedometer can display half the vehicle's true speed, creating a crash hazard. Consumers should stop using the vehicles and contact a Can-Am dealer for a free repair.

    Product
    2022 Can-Am Outlander ATVs
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·22722·2022-02-10

    Serta Perfect Sleeper Mattresses Recalled for Fire Hazard

    Serta is recalling about 800 Perfect Sleeper mattresses because they fail to meet federal flammability standards, creating a fire hazard. No injuries have been reported.

    Product
    Serta® Perfect Sleeper® Mattresses
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·22V076000·2022-02-10

    2022 Thor Motor Coach Motorhomes Rear Ladder Installation Defect Recall

    Thor Motor Coach is recalling 2022 ACE, Freedom Traveler, Hurricane, and Windsport motorhomes. The rear ladder may have been installed on the wrong side, which could break while in use and cause injury.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH ACE, FREEDOM TRAVELER, HURRICANE, WINDSPORT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·22078·2022-02-10

    WORX 13 Amp 1900 PSI Electric Pressure Washers Recalled for Hose Separation

    Positec USA is recalling about 17,630 WORX Brand 13 Amp 1900 PSI Electric Pressure Washers because the sprayer hose can separate from the spray wand during use, posing an impact injury hazard. Four minor injuries including cuts and bruises have been reported.

    Product
    WORX® Brand 13 Amp 1900 PSI Electric Pressure Washers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • ModerateCPSC·22720·2022-02-10

    Ski-Doo 2022 Snowmobiles Recalled Due to Speedometer Crash Hazard

    BRP is recalling approximately 400 Ski-Doo 2022 snowmobiles because the speedometer may display half the vehicle's true speed, creating a crash hazard. Consumers should stop using the recalled snowmobiles and contact a Ski-Doo dealer for free repair.

    Product
    Ski-Doo Snowmobiles
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • ModerateCPSC·22723·2022-02-10

    Shop LC Electric Space Heaters Recalled Due to Fire and Burn Hazards

    Shop LC is recalling about 4,500 personal electric space heaters that can overheat, posing fire and burn hazards. Consumers should stop using them immediately and return the product for a refund.

    Product
    Personal Electric Space Heaters
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0463-2022·2022-02-09

    Medroxyprogesterone Acetate Injection Recalled for Sterility Assurance

    Ideal Specialty Apothecary is recalling Medroxyprogesterone Acetate Injection due to lack of assurance of sterility. The recall affects approximately 57,994 vials distributed nationwide.

    Product
    Medroxyprogesterone Acetate Injection, IM, 150 mg/mL, packaged in 1 ml Single Dose Vial, RX Only, Ideal Pharmacy, 2333 Morris Ave, Union, NJ 07083
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0530-2022·2022-02-09

    Baxter SIGMA Spectrum infusion pumps recalled for medication delivery failures

    Baxter is recalling 146,502 SIGMA Spectrum infusion pumps due to potential medication delivery failures that may occur without alerting clinicians. The issue is linked to administration set setup and occlusion alarm resolution.

    Product
    Baxter SIGMA Spectrum Infusion Pump with Master Drug Library (Version 8), Product code 35700BAX2.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0529-2022·2022-02-09

    Baxter Spectrum IQ Infusion Pumps Recalled Due to Potential Medication Delivery Failure

    Baxter Healthcare is recalling 241,304 Spectrum IQ infusion pumps due to potential medication delivery failure without user alert. The issue may occur during administration set setup or when occlusion alarms are not fully resolved.

    Product
    Baxter Spectrum IQ Infusion Pumps, Product code 3570009.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0480-2022·2022-02-09

    COVID-19 Rapid Antigen Test Kit Distributed Without FDA Approval

    CovClear COVID-19 Rapid Antigen Test kits (284,575 units) were distributed nationwide without FDA marketing approval, clearance, or authorization. All lots are recalled.

    Product
    CovClear COVID-19 Rapid Antigen Test, ATG 900-031
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0481-2022·2022-02-09

    COVID-19 Test Kits Recalled for Unauthorized FDA Marketing and Sale

    Empowered Diagnostics LLC recalled COVID-19 test kits (ImmunoPass, NAB 900-60) sold nationwide without FDA approval. Approximately 2,100 units were distributed without required marketing clearance or authorization.

    Product
    ImmunoPass , COVID-19 Neutralizing Antibody Test, NAB 900-60
    Category
    Medical Device
    Distribution
    Distributed nationwide