The Recall Desk

State

Hawaii product recalls

72,940 recalls have nationwide distribution and so reach Hawaii. 2,766 additional recalls listed Hawaii specifically in their distribution scope.

What the numbers show

Total
2,766
Critical
333
Severe
567
Most recent
2026-09-09

Of the 2,766 recalls naming Hawaii we have scored against our rubric, 333 (12%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 567 (20%) are Severe.

These figures cover only the 2,766 recalls whose distribution notice names Hawaii specifically. The 72,940 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

3876–3900 of 75706

  • HighCPSC·26162·2025-12-18

    SereneLife above-ground pools recalled over a strap that creates a foothold

    About 80 SereneLife above-ground pools 48 inches and taller, models SLPORND15 and SLPORND18, are being recalled because a compression strap may create a foothold allowing a child to access the pool.

    Product
    SereneLife brand 48-inch and taller above-ground pools
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·26155·2025-12-18

    Chandeliers recalled because an improperly threaded component lets fixtures fall

    About 260 Currey & Company Electra chandeliers are being recalled because the component connecting the fixture to the ceiling mount is not threaded properly and the fixture can fall.

    Product
    Electra Chandelier and Electra Three Tier Chandelier light fixtures
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·25V884000·2025-12-18

    2025 Ford Maverick vehicles recalled for instrument panel separation

    Ford is recalling certain 2025 and 2026 Maverick vehicles because the instrument panel cover may separate during an airbag deployment, potentially striking occupants and increasing injury risk.

    Product
    FORD — FORD MAVERICK
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V889000·2025-12-18

    2026 Subaru Forester Rear Hatch Support Bracket Detachment Risk

    Subaru is recalling certain 2026 Forester vehicles because the rear hatch support bracket may detach without warning, allowing the rear hatch to fall unexpectedly and increase injury risk.

    Product
    SUBARU — SUBARU FORESTER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V890000·2025-12-18

    Altec aerial device taillight wiring may lack adequate circuit protection

    Altec is recalling certain 2023-2025 Aerial Device and Digger Derrick vehicles because the electronic taillight module harness may have inadequate circuit protection.

    Product
    ALTEC — ALTEC DIGGER DERRICK, AERIAL DEVICE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·26153·2025-12-18

    Eight-drawer fabric dressers recalled over tip over and entrapment hazards

    About 16,800 Furnulem 8-Drawer Dressers are being recalled because they are unstable if not anchored to the wall and violate the mandatory standard required by the STURDY Act.

    Product
    Furnulem 8-Drawer Dressers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·25V888000·2025-12-18

    Ford Bronco rearview image may remain displayed after backing ends

    Ford is recalling certain 2021-2022 Bronco vehicles previously repaired under recall 23V165, because the rearview camera image may still be displayed after a backing event has ended.

    Product
    FORD — FORD BRONCO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·26163·2025-12-18

    Above-ground pools recalled because a compression strap can create a foothold

    About 13,400 Blue Wave above-ground pools 48 inches and taller are being recalled because the compression strap around the outside of the pool legs may create a foothold for children.

    Product
    Blue Wave brand 48-inch and taller above-ground pools
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·26164·2025-12-18

    Toy play purse sets recalled over accessible button and coin batteries

    About 3,090 Meaicezli Play Purse Sets are being recalled because the toy cell phone contains button cell batteries and the toy tablet a lithium coin battery that children can easily access.

    Product
    Meaicezli Play Purse Sets
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·25V891000·2025-12-18

    2024–2026 Honda CBR600RR Motorcycles Engine Defect Recall

    Honda is recalling 2024–2026 CBR600RR motorcycles because the cylinder head may have been improperly manufactured, risking rear wheel lockup and engine fire.

    Product
    HONDA — HONDA CBR600RR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V878000·2025-12-18

    2025–2026 Chevrolet Equinox EV Pedestrian Alert System Defect

    General Motors is recalling 2025–2026 Chevrolet Equinox EV vehicles because the pedestrian alert sound system may not produce sufficient volume change between stopped and low-speed operation, failing to meet federal safety standards.

    Product
    CHEVROLET — CHEVROLET EQUINOX EV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·26159·2025-12-18

    Nine-drawer fabric dressers recalled over tip over and entrapment hazards

    About 4,740 KKL Fabric 9-Drawer Dressers are being recalled because they are unstable if not anchored to the wall and violate the mandatory standard required by the STURDY Act.

    Product
    KKL Fabric 9-Drawer Dressers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0892-2026·2025-12-17

    Frozen surti undhiu mix recalled after testing positive for Salmonella

    Chetak New York is recalling Deep-brand frozen surti undhiu mix after the product tested positive for Salmonella. The FDA has classified the action as Class I.

    Product
    Brand Name: FORZA" PTC Spacer System Product Name: FORZA" PTC Spacer System Model/Catalog Number: 38-1007SP FORZA PTC Spacer, Straight, 0¿, 9W x 23L x 7H 38-1008SP FORZA PTC Spacer, Straight, 0¿, 9W x 23L x 8H; 38-1009SP FORZA PTC Spacer, Straight, 0¿, 9W x 23L x 9H; 38-1010
    Category
    Food
    Distribution
    Distributed nationwide
  • CriticalFDA (Food)·H-0316-2026·2025-12-17

    Bagged peaches recalled over potential Listeria monocytogenes contamination

    Moonlight Packing is recalling 46,048 cases of 2 lb bagged peaches, including Kroger-distributed packs, over potential contamination with Listeria monocytogenes.

    Product
    UPC 8 98429 00209 1 PEACHES PRODUCE OF U.S.A. NET WT 2 LB (32 OZ) 907 g DISTRIBUTED BY MOONLIGHT PACKING CORP. REEDLEY, CALIFORNIA 93654 UPC 0 11110 18174 9 PEACHES PRODUCE OF USA NET WT 32 OZ (2 LB) 907g DISTRIBUTED BY THE KROGER CO. CINCINNATI, OHIO 45202
    Category
    Food
    Distribution
    39 states
  • CriticalFDA (Food)·H-0314-2026·2025-12-17

    Packaged yellow peaches recalled over potential Listeria monocytogenes contamination

    Moonlight Packing is recalling 483,973 cases of 4 lb packaged yellow peaches over potential contamination with Listeria monocytogenes. The FDA has classified the action as Class I.

    Product
    UPC 8 10248 03165 6 YELLOW Peaches PRODUCE OF U.S.A. NET WT. 4 LBS. MOONLIGHT PACKING CORP. REEDLEY, CALIFORNIA 93654 UPC 8 98429 00220 6 YELLOW Peaches from California PRODUCE OF U.S.A. NET WT. 4 LBS. MOONLIGHT PACKING CORP. REEDLEY, CALIFORNIA 93654
    Category
    Food
    Distribution
    39 states