The Recall Desk

State

Hawaii product recalls

72,940 recalls have nationwide distribution and so reach Hawaii. 2,766 additional recalls listed Hawaii specifically in their distribution scope.

What the numbers show

Total
2,766
Critical
333
Severe
567
Most recent
2026-09-09

Of the 2,766 recalls naming Hawaii we have scored against our rubric, 333 (12%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 567 (20%) are Severe.

These figures cover only the 2,766 recalls whose distribution notice names Hawaii specifically. The 72,940 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

3826–3850 of 75706

  • ModerateFDA (Devices)·Z-0956-2026·2025-12-24

    Children's mouthguards recalled for distribution without FDA premarket clearance

    Myofunctional Research Company USA is recalling 436 Myosa for Kids devices because the firm mistakenly distributed the product within the US without FDA premarket clearance or approval.

    Product
    Myosa for Kids KS1 REF MyOSAKS1_Sb/Sp/Mb/Mp/Lb/Lc KS2 REF MyOSAKS2_Sb/Sc/Mb/Mc/Mp/Lb/Lc Myosa for Kids is a mouthguard in 3 different sizes (sm, med, lg) that can be used in children ages 3-15 to address breathing and myofunctional disorders. Catalog Numbers:
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0237-2026·2025-12-24

    Cisatracurium 200 mg vials recalled after subpotent stability assay results

    Somerset Therapeutics is recalling 28,660 vials of Cisatracurium Besylate Injection, 200mg/20mL, after out of specification assay results during long term stability testing.

    Product
    CISATRACURIUM BESYLATE — CISATRACURIUM BESYLATE (CISATRACURIUM BESYLATE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0234-2026·2025-12-24

    Phentolamine mesylate injection recalled over cracked and broken cartridges

    Novocol Pharmaceutical of Canada is recalling 1,636 cartons of OraVerse (Phentolamine Mesylate) Injection over a defective container with cracked or broken cartridges.

    Product
    ORAVERSE — ORAVERSE (PHENTOLAMINE MESYLATE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0240-2026·2025-12-24

    Ciclopirox shampoo recalled after failing impurity specifications at eighteen months

    Sun Pharma/Taro is recalling 17,664 units of Ciclopirox Shampoo 1% after out of specification impurity and degradation results at the 18-month timepoint.

    Product
    Ciclopirox Shampoo, 1%, 120 mL, Rx only, Mfg by: Taro Pharmaceuticals Inc., Ontario, Canada; Dist. by: Taro Pharmaceuticals USA, Inc., NY 10532. NDC 51672-1351-08
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0236-2026·2025-12-24

    Cisatracurium 10 mg vials recalled after subpotent stability assay results

    Somerset Therapeutics is recalling 52,340 vials of Cisatracurium Besylate Injection, 10 mg/5 mL, after out of specification assay results during long term stability testing.

    Product
    CISATRACURIUM BESYLATE — CISATRACURIUM BESYLATE (CISATRACURIUM BESYLATE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0231-2026·2025-12-24

    Mepivacaine dental cartridges recalled over cracked and broken containers

    Novocol Pharmaceutical of Canada is recalling 5,520 cartons of Mepivacaine HCl 3% injection over a defective container with cracked or broken cartridges.

    Product
    MEPIVACAINE — MEPIVACAINE (MEPIVACAINE HYDROCHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0238-2026·2025-12-24

    Cisatracurium 20 mg multiple-dose vials recalled after subpotent assay results

    Somerset Therapeutics is recalling 71,310 vials of Cisatracurium Besylate Injection, 20 mg/10 mL, after out of specification assay results during long term stability testing.

    Product
    CISATRACURIUM BESYLATE — CISATRACURIUM BESYLATE (CISATRACURIUM BESYLATE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0229-2026·2025-12-24

    Lidocaine and epinephrine dental cartridges recalled over cracked containers

    Novocol Pharmaceutical of Canada is recalling 12,033 cartons of Lidocaine HCl 2% with Epinephrine 1:100,000 injection over a defective container with cracked or broken cartridges.

    Product
    LIDOCAINE — LIDOCAINE (LIDOCAINE HYDROCHLORIDE AND EPINEPHRINE BITARTRATE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0230-2026·2025-12-24

    Polocaine dental cartridges recalled over cracked and broken containers

    Novocol Pharmaceutical of Canada is recalling 5,825 units of 3% Polocaine Dental mepivacaine injection over a defective container with cracked or broken cartridges.

    Product
    POLOCAINE — POLOCAINE (MEPIVACAINE HYDROCHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0232-2026·2025-12-24

    Benco mepivacaine cartridges recalled over cracked and broken containers

    Novocol Pharmaceutical of Canada is recalling Mepivacaine HCl 3% injection distributed by Benco Dental over a defective container with cracked or broken cartridges.

    Product
    MEPIVACAINE — MEPIVACAINE (MEPIVACAINE HYDROCHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0233-2026·2025-12-24

    Carbocaine dental cartridges recalled over cracked and broken containers

    Novocol Pharmaceutical of Canada is recalling 40 cartons of Cook-Waite Carbocaine 3% mepivacaine injection over a defective container with cracked or broken cartridges.

    Product
    CARBOCAINE — CARBOCAINE (MEPIVACAINE HYDROCHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0957-2026·2025-12-24

    Bone fixation screws recalled over a labeling error on one lot

    Smith & Nephew is recalling 168 BIOSURE HA Screws, 6mm x 20mm, due to a labeling error on the affected lot.

    Product
    BIOSURE HA SCREW, 6MM x 20 MM. Threaded metallic bone fixation fastener.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0228-2026·2025-12-24

    Xylocaine dental cartridges recalled over cracked and broken containers

    Novocol Pharmaceutical of Canada is recalling 18,789 cartons of 2% Xylocaine Dental with Epinephrine over a defective container with cracked or broken cartridges.

    Product
    2% Xylocaine DENTAL with Epinephrine 1:100,000 (Lidocaine HCI and Epinephrine Injection USP), packaged in a carton containing 50 single-dose cartridges, 1.7 mL each, Rx only, Manufactured for Dentsply Pharmaceutical, York, PA 17404, by Novocol Pharmaceutical of Canada, Inc., NDC
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V909000·2025-12-23

    Altec Recalls 2022-2023 Aerial Work Platforms Due to Missing Check Valve

    Altec is recalling 2022-2023 AA55, AM55, AN46, and AN55 vehicles because a missing check valve may reduce boom insulation, increasing the risk of electric shock.

    Product
    ALTEC — ALTEC AN46, AM55, AA55, AN55
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V906000·2025-12-23

    BMW i4 positive battery cable connection may become loose

    BMW is recalling one 2025 i4 eDrive40 vehicle because the connection between the positive battery cable and the rear power distributor may become loose.

    Product
    BMW — BMW I4 EDRIVE40
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V907000·2025-12-23

    KTM motorcycle side stand spring may break and fall down

    KTM is recalling certain 2025 390 Adventure R, 390 Adventure X, 390 SMC R and 390 Enduro R motorcycles because engine vibrations may break the side stand spring, letting the stand fall to the ground.

    Product
    KTM — KTM 390 ENDURO R, 390 ADVENTURE X, 390 SMC R, 390 ADVENTURE R
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V908000·2025-12-23

    Volvo rearview camera image may not display when reversing

    Volvo is recalling certain 2021-2025 vehicles across the XC40, XC60, XC90, S60, S90, V60 and V90 ranges because the rearview camera image may not display when the vehicle is in reverse.

    Product
    VOLVO — VOLVO C40BEV, EC40, EX40, XC90
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V911000·2025-12-23

    Honda CBR650R wiring damage can blow the fuse for lights

    Honda is recalling certain 2024-2025 CBR650R motorcycles because engine vibration may damage the turn signal switch wire harness, causing a short circuit and a blown fuse.

    Product
    HONDA — HONDA CBR650R
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V905000·2025-12-23

    Tiffin motorhome generator wiring harness may contain undersized wires

    Tiffin is recalling certain 2025-2026 Open Trail motorhomes fitted with an optional diesel or propane generator because the wiring harness may contain incorrectly sized wires.

    Product
    TIFFIN — TIFFIN OPEN TRAIL
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V910000·2025-12-23

    Spartan Fire Emergency Vehicles Recalled for Ladder Handle Defect

    Spartan Fire is recalling certain emergency vehicles because a ladder handle may detach, allowing ground ladders to fall off and creating a road hazard.

    Product
    SPARTAN FIRE — SPARTAN FIRE STAR SERIES, UST BODY, LEGEND SERIES
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • ModerateNHTSA·25V912000·2025-12-23

    2026 Nissan Rogue Vehicles with Incorrect Spare Tire Assembly

    Nissan is recalling 2026 Rogue vehicles with an incorrect-size spare tire that does not match the tire placard information. This may lead to improper tire inflation and increased crash risk.

    Product
    NISSAN — NISSAN ROGUE
    Category
    Vehicle
    Distribution
    Distributed nationwide