The Recall Desk

State

Georgia product recalls

73,912 recalls have nationwide distribution and so reach Georgia. 9,641 additional recalls listed Georgia specifically in their distribution scope.

What the numbers show

Total
9,641
Critical
1,471
Severe
2,571
Most recent
2026-11-11

Of the 9,641 recalls naming Georgia we have scored against our rubric, 1,471 (15%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 2,571 (27%) are Severe.

These figures cover only the 9,641 recalls whose distribution notice names Georgia specifically. The 73,912 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

75826–75850 of 83553

  • HighFDA (Devices)·Z-2045-2012·2012-07-25

    Terumo Sarns Modular Perfusion System 8000 Recalled for Air Bubble Detection Malfunctions

    Terumo is recalling Sarns Modular Perfusion System 8000 units due to reported malfunctions in the Air Bubble Detection System, including false alarms and over-sensitivity.

    Product
    Sarns Modular Perfusion System 8000 base, 5 pump 115V. The Sarns Modular Perfusion Systern 8000 is indicated for use for up to 6 hours on the extracorporeal circulation of blood for arterial perfusion, regional perfusion, and cardiopulmonary bypass procedures, when used by a…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·12V354000·2012-07-25

    Hyundai Recalls 2007-2009 Santa Fe Vehicles for Airbag Sensor Issue

    Hyundai is recalling 2007-2009 Santa Fe vehicles because the occupant classification system may fail to detect small adults, potentially preventing the front passenger airbag from deploying.

    Product
    HYUNDAI — HYUNDAI SANTA FE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2043-2012·2012-07-25

    Terumo Advanced Perfusion System 1 recalled for air bubble detection malfunctions

    Terumo is recalling 648 Advanced Perfusion System 1 units worldwide due to reported malfunctions in the Air Bubble Detection System, including false alarms and oversensitivity.

    Product
    Terumo Advanced Perfusion System 1. System 1 base 220/240V. The Terumo Advanced Perfusion System I is indicated for use in extracorporeal circulation of blood for arterial perfusion, regional perfusion, and cardiopulmonary bypass procedures only When used by a qualified…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2052-2012·2012-07-25

    Terumo Sarns Modular Perfusion System 9000 Recalled for Air Bubble Detection Malfunctions

    Terumo is recalling 31 Sarns Modular Perfusion System 9000 units worldwide due to reported malfunctions in the Air Bubble Detection System, including false alarms and over-sensitivity.

    Product
    Sarns Modular Perfusion System 9000, 100V with color screen. The Sarns Perfusion System 9000 is indicated for use as a heart-lung system for pumping blood for arterial perfusion, regional perfusion, and cardiopulmonary bypass procedures, when used by a qualified perfusionist…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2010-2012·2012-07-25

    Terumo Advanced Perfusion System 1 Recalled for Network Communication Failures

    Terumo is recalling 648 Advanced Perfusion System 1 units due to reports of communications or power failures in the system network.

    Product
    Terumo Advanced Perfusion System 1 System 1 Base, 220/240V. The Terumo Advanced Perfusion System 1 is indicated for use for up to 6 hours on the extracorporeal circulation of blood for arterial perfusion, regional perfusion, and cardiopulmonary bypass procedures, when used…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2016-2012·2012-07-25

    Stryker Recalls T2 Knee Arthrodesis Nails Due to Sterile Barrier Breach Risk

    Stryker is recalling 532 units of T2 Knee Arthrodesis Nails because of a potential breach in the sterile packaging barrier.

    Product
    Stryker T2 Arthrodesis Nailing System. Manufacturer: Stryker Trauma GmbH, Professor-Kuntscher-Str. 1-5, 24232 Schonkirchen Germany. Distributed in the USA by Stryker Orthopaedics, 325 Corporate Drive, Mahwah, NJ 07430. The T2 Arthrodesis Nail is intended for the treatment…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2035-2012·2012-07-25

    Philips Brilliance CT Scanners Recalled for Defective Carbon Table Top Bolts

    Philips Medical Systems is recalling 524 Brilliance CT scanners because defective bolts securing the carbon table top may break off.

    Product
    Philips Brilliance 6, 16, 40, 64, Big Bore, iCT and iCT SP are Computed Tomography X-Ray Systems. The devices are Computed Tomography Systems that are intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data taken at…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2033-2012·2012-07-25

    Stryker AVS Navigator Trials Recalled for Shaft Failure

    Stryker Spine is recalling AVS Navigator Trials because the shaft may fail at the junction of the trial head.

    Product
    Stryker AVS Navigator Trials 6mm-15mm Manufactured by: Stryker Spine SAS Z.1 Marticot-33610-Cestas -France +33 (0) 5.57.97.06.30 http;//www.stryker.com Distributed in the USA by Stryker Spine 2 Pearl Court. Allendale NJ 07401-1677 USA +1-201-780-8000 Cestas France…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2015-2012·2012-07-25

    GE Healthcare Recalls Invasive Blood Pressure Care Cables

    GE Healthcare is recalling 279 invasive blood pressure care cables due to a faulty O-ring that prevents correct blood pressure monitoring.

    Product
    GE Healthcare, Invasive Blood Pressure Care Cables. Product ID Number: 2016995-001, 2016995-002, 2016995-003, 2016995-004.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2042-2012·2012-07-25

    Terumo Advanced Perfusion System Recalled for Air Bubble Detection Malfunctions

    Terumo is recalling 992 Advanced Perfusion System I units worldwide due to reported malfunctions in the Air Bubble Detection System, including oversensitivity and false alarms.

    Product
    Terumo Advanced Perfusion System 1. System 1 base 100/120V. The Terumo Advanced Perfusion System I is indicated for use in extracorporeal circulation of blood for arterial perfusion, regional perfusion, and cardiopulmonary bypass procedures only When used by a qualified…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2047-2012·2012-07-25

    Terumo Sarns Modular Perfusion System 8000 Recalled for Air Bubble Detection Malfunctions

    Terumo is recalling 310 Sarns Modular Perfusion System 8000 units worldwide due to reported malfunctions in the Air Bubble Detection System, including false alarms and over-sensitivity.

    Product
    Sarns Modular Perfusion System 8000 base, 5 pump 220/240V. The Sarns Modular Perfusion System 8000 is indicated for use for up to 6 hours on the extracorporeal circulation of blood for arterial perfusion, regional perfusion, and cardiopulmonary bypass procedures, when used by…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2039-2012·2012-07-25

    Alere Triage Tox+MTD Drug Screen Recalled for Decreased Precision and Accuracy

    Alere San Diego is recalling 9,997 Triage Tox+MTD Drug Screen kits because they may produce false positive or negative results due to decreased precision and accuracy.

    Product
    Alere Triage Tox+MTD Drug Screen, PN 94400 Product Usage: The Alere Triage TOX Drug Screen is a fluorescence immunoassay to be used with the Alere Triage Meters for the qualitative determination of the presence of drug and/or the major metabolites above the threshold…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2018-2012·2012-07-25

    Kimberly-Clark Recalls MicroCool Surgical Gowns Due to Fabric Defects

    Kimberly-Clark is recalling specific lots of MicroCool surgical gowns because they pill, lint, or allow blood to pass through.

    Product
    MicroCool Breathable Impervious Gown with Secure Fit Surgical, (Large and X-Large), Made in Honduras. The Kimberly Clark Micro COOL Surgical Gowns are sterile single use surgical apparel intended to be worn by heathcare professionals to help protect the patient and the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2048-2012·2012-07-25

    Terumo Sarns Modular Perfusion System 8000 Recalled for Air Bubble Detection Malfunctions

    Terumo is recalling 26 Sarns Modular Perfusion System 8000 units due to reported malfunctions in the Air Bubble Detection System, including false alarms and over-sensitivity.

    Product
    Sarns Modular Perfusion System 8000 base, 4 pump 100V. The Sarns Modular Perfusion System 8000 is indicated for use for up to 6 hours on the extracorporeal circulation of blood for arterial perfusion, regional perfusion, and cardiopulmonary bypass procedures, when used by a…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2051-2012·2012-07-25

    Terumo Sarns Modular Perfusion System 9000 Recalled for Air Bubble Detection Malfunctions

    Terumo Cardiovascular Systems is recalling 286 Sarns Modular Perfusion System 9000 units worldwide due to reported malfunctions in the Air Bubble Detection System, including false alarms and over-sensitivity.

    Product
    Sarns Modular Perfusion System 9000, 220/240V with color screen. The Sarns Perfusion System 9000 is indicated for use as a heart-lung system for pumping blood for arterial perfusion, regional perfusion, and cardiopulmonary bypass procedures, when used by a qualified…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·12V362000·2012-07-25

    Micro Bird Recalls G5 School Buses for Roof Hatch Friction Issues

    Micro Bird is recalling 2011-2012 G5 school buses because roof escape hatches may be too hard to open, potentially hindering emergency egress.

    Product
    MICRO BIRD — MICRO BIRD G5 SCHOOL BUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2020-2012·2012-07-25

    Terumo Advanced Perfusion System 1 Recalled for Power Malfunction

    Terumo is recalling 992 Advanced Perfusion System 1 units due to a power loss error message that may affect system stability during medical procedures.

    Product
    System 1 Base, 100/120V. The Terumo Advanced Perfusion System 1 is indicated for use for up to 6 hours on the extracorporeal circulation of blood for arterial perfusion, regional perfusion, and cardiopulmonary bypass procedures, when used by a qualified medical professional…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2017-2012·2012-07-25

    Kimberly-Clark Recalls MicroCool Surgical Gowns Due to Material Defects

    Kimberly-Clark is recalling specific lots of MicroCool surgical gowns because they pill, lint, or allow blood strikethrough, potentially compromising sterility.

    Product
    MicroCool Breathable Impervious Surgical Gown, (Large and X-Large), Sterile, Made in Honduras. The Kimberly Clark Micro COOL Surgical Gowns are sterile single use surgical apparel intended to be worn by heathcare professionals to help protect the patient and the healthcare…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2050-2012·2012-07-25

    Terumo Sarns Modular Perfusion System 9000 Recalled for Air Bubble Detection Malfunctions

    Terumo is recalling 484 Sarns Modular Perfusion System 9000 units worldwide due to reported malfunctions in the Air Bubble Detection System, including false alarms and over-sensitivity.

    Product
    Sarns Modular Perfusion System 9000, 115V with color screen. The Sarns Perfusion System 9000 is indicated for use as a heart-lung system for pumping blood for arterial perfusion, regional perfusion, and cardiopulmonary bypass procedures, when used by a qualified perfusionist…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2021-2012·2012-07-25

    Terumo Advanced Perfusion System 1 Recalled for Power Fluctuation Errors

    Terumo is recalling 648 Advanced Perfusion System 1 units due to a Red X error indicating loss or fluctuation of internal power on one side of the base.

    Product
    System 1 Base, 220/240V. The Terumo Advanced Perfusion System 1 is indicated for use for up to 6 hours on the extracorporeal circulation of blood for arterial perfusion, regional perfusion, and cardiopulmonary bypass procedures, when used by a qualified medical professional…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2011-2012·2012-07-25

    Stingray Surgical Recalls Bipolar Forceps Due to Uncleared Instructions

    Stingray Surgical Products is recalling bipolar forceps because the Instructions For Use were altered without FDA clearance.

    Product
    Bipolar Forceps model number: S02-XXX, S03-XXX, P02-XXX, and P03-XXX. "Instructions For Use" (QF7.5.1A.R01 thru QF7.5.1A.R06 Care and Handling of Bipolar Forceps. Bipolar Forceps designed to grasp, manipulate and coagulate selected tissue for use in general surgical…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1993-2012·2012-07-25

    GE Healthcare Recalls Optima Mobile X-ray Systems Due to Software Issue

    GE Healthcare is recalling Optima XR200 and XR220 mobile X-ray systems because a software issue affects the visual indication required by regulations.

    Product
    GE Healthcare Optima Mobile X-ray System. The GE Automatic Mobile X-Ray (AMX ) Series are intended to take exposures utilizing film or computed radiography ( CR )
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2029-2012·2012-07-25

    Gulf Fiberoptics Recalls GMF-RC65 Surgical Headlight Cables

    Gulf Fiberoptics, Inc. is recalling 169 GMF-RC65 Replacement Surgical Headlight Cables because the light-transmitting fiber material differs from the approved 510(k) design.

    Product
    GMF-RC65 Replacement Surgical Headlight Cable for Cogent Microlink. GMF-RC65 Replacement Surgical Headlight Cable for Cogent Microlink is used to transmit light.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2032-2012·2012-07-25

    Becton Dickinson Recalls Gram Crystal Violet Stain Reagents

    Becton Dickinson is recalling Gram Crystal Violet 250 mL reagents due to potential artifacts that may interfere with the identification of microorganisms.

    Product
    Gram Crystal Violet 250 mL, catalog #212525, in cartons of 4 bottles. Gram Stain Kits and Reagents are used to stain microorganisms from cultures or specimens by the differential Gram method.
    Category
    Medical Device
    Distribution
    Distributed nationwide