The Recall Desk

State

District of Columbia product recalls

73,503 recalls have nationwide distribution and so reach DC. 2,798 additional recalls listed District of Columbia specifically in their distribution scope.

What the numbers show

Total
2,798
Critical
240
Severe
1,083
Most recent
2026-09-23

Of the 2,798 recalls naming District of Columbia we have scored against our rubric, 240 (9%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,083 (39%) are Severe.

These figures cover only the 2,798 recalls whose distribution notice names District of Columbia specifically. The 73,503 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

22801–22825 of 76301

  • HighCPSC·22728·2022-02-17

    H&M Children's Sleepwear Sets Violate Federal Flammability Standards

    H&M is recalling about 615 children's sleepwear sets sold online from October to November 2021 because they fail to meet federal flammability standards for children's sleepwear, posing a risk of burn injuries.

    Product
    Children's Sleepwear Sets
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·22730·2022-02-17

    Lovevery Steel Drinking Cups With Handle Recalled for Choking Hazard

    Lovevery is recalling steel drinking cups with handles included in Inspector Play Kits because the handle can detach, posing a choking hazard to young children. About 169,000 units were sold online from July 2018 through July 2021.

    Product
    Steel drinking cups with handle
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·22724·2022-02-17

    Zeno Infant Walkers Recalled Due to Fall and Entrapment Hazards

    Zeno collapsible infant walkers fail to meet federal safety standards and pose fall and neck entrapment risks to babies. Consumers should stop using the walkers immediately and contact Zeno for a free return and refund.

    Product
    Infant Walkers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • CriticalUSDA FSIS·005-2022·2022-02-16

    Morgan Foods Recalls Skyline Chili Cans for Undeclared Allergens

    Morgan Foods is recalling Skyline chili cans that contain undeclared milk, wheat, and soy allergens. The product may actually be cream of chicken soup.

    Product
    Morgan Foods, Inc. — Morgan Foods Recalls Skyline Chili Products due to Misbranding and Undeclared Allergens
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-0809-2022·2022-02-16

    Siren Birthday Cake Protein Bites recalled for undeclared cashews and almond butter

    Siren Snacks recalls Siren Birthday Cake Protein Bites for undeclared cashews and almond butter allergens that may pose a risk to consumers with nut allergies.

    Product
    Siren Birthday Cake Protein Bites, Item # 1104, brand Siren Snacks, packaged in 1.7 oz (48g) plastic pouch, 10 individual pouches per caddie. Caddie UPC: 8-62768-00049-0; Pouch UPC: 8 62768-00048-3. The affected label is read in parts: "***12G PLANT PROTEIN***INGREDIENTS…
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0564-2022·2022-02-16

    FDA Recalls Unauthorized E25Bio COVID-19 Diagnostic Test Kit

    E25Bio COVID-19 diagnostic tests have been recalled following nationwide distribution without FDA authorization or approval. The distributed units lacked sufficient directions and quality controls needed for safe diagnostic use.

    Product
    E25Bio COVID-19 Direct Antigen Rapid Test ; E25Bio COVID-19 DART Kit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V089000·2022-02-16

    Ford E-350 and E-450 Power Steering Hydraulic Defect Recall

    Ford is recalling certain 2021-2022 E-350 and E-450 vehicles with dual rear wheels due to inadequate power steering line connections. This defect may cause sudden loss of power steering fluid, resulting in loss of steering and brake assist.

    Product
    FORD — FORD E-450, E-350
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-0732-2022·2022-02-16

    Wishbone salad dressing recalled nationwide for undeclared eggs

    Conagra Brands is recalling Wishbone Chunky Blue Cheese Dressing due to undeclared eggs on the label. Consumers with egg allergies should not use this product and should return or dispose of any affected bottles.

    Product
    Wishbone Chunky Blue Cheese Dressing 24oz. bottle UPC 0-41321-00691-3; six bottles per case
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0557-2022·2022-02-16

    MegMan Performance Booster capsules recalled for undeclared tadalafil

    Junp Hydration LLC is recalling MegMan Performance Booster 800 mg capsules because the product contains undeclared tadalafil, an active pharmaceutical ingredient not listed on the label, making it an unapproved drug.

    Product
    MegMan Performance Booster, 800 mg capsules, packaged in 10-count blisters packaged in a carton, UPC 8 48998 00091 2, ASIN B08Z74KS88
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-0731-2022·2022-02-16

    Dressing Recall: Wishbone Thousand Island Contains Undeclared Egg Allergen

    Conagra Brands is recalling Wishbone Thousand Island Dressing due to undeclared eggs. The recall affects 4,971 cases distributed to retailer distribution centers nationwide.

    Product
    Wishbone Thousand Island Dressing 15oz. bottle UPC 0-41321-00645-6 and 24 oz. bottle UPC 0-41321-00731-6; six bottles per case
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0556-2022·2022-02-16

    Polymyxin B for Injection Recalled Due to Particulate Matter Contamination

    AuroMedics Pharma LLC is recalling Polymyxin B for Injection USP (Lot CPB200013) nationwide due to the presence of particulate matter, including hair, found in vials.

    Product
    POLYMYXIN B — POLYMYXIN B (POLYMYXIN B)
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0561-2022·2022-02-16

    HARD DAWN Rise and Shine Capsules Recalled for Undisclosed Tadalafil

    HARD DAWN Rise and Shine capsules (500 mg) are being recalled because they contain tadalafil, an FDA-approved drug, without proper approval or labeling. The product was sold nationwide via Amazon.

    Product
    HARD DAWN, Rise and Shine capsules, 500 mg, packaged in 10-count blisters per carton, Made in Malaysia, UPC 680044 364926, ASIN: B077XCCL59
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0595-2022·2022-02-16

    GE Healthcare MR Magnets Cryogenic Ventilation System Defect Recall

    GE Healthcare is recalling 17,228 MR superconducting magnet systems because the cryogenic ventilation system may not meet required venting standards.

    Product
    GE Healthcare MR superconducting magnets, a component of GE Healthcare SIGNA PET/MR System, tomographic imager combining emission computed tomography with nuclear magnetic resonance system.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0584-2022·2022-02-16

    KWIK-STIK Quality Control Sets recalled for potential bacterial contamination

    Microbiologics Inc is recalling KWIK-STIK QC Sets and Panels due to potential contamination with E. coli and Staphylococcus species. The affected product was distributed worldwide to laboratory testing facilities.

    Product
    QC Sets and Panels: KWIK-STIK" 2 Pack. Common Name: QC Sets and Panels GP Comprehensive QC Set. Each KWIK-STIK unit contains a lyophilized microorganism pellet, an ampoule of hydrating fluid, and an inoculating swab. Each device is sealed within a laminated pouch that…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0562-2022·2022-02-16

    Novalung Sensor Box Communication Failure May Disable Flow Measurement

    The Novalung Sensor Box may experience communication failures between its flow sensor and sensor box component, potentially disabling flow measurement and air bubble detection. The recall affects 115 units distributed across 16 US states.

    Product
    Novalung Sensor Box (F30000163) a component of Novalung Console (F30000162)- Indicated for long-term (> 6 hours) respiratory/ cardiopulmonary support that provides assisted extracorporeal circulation and physiologic gas exchange (oxygenation and CO2 removal) of the patient's…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0635-2022·2022-02-16

    Acufex Access Advanced Positioning Kit Recalled for Missing Sterilization

    Smith & Nephew is recalling the Acufex Access Advanced Positioning Kit because the products were shipped to a distribution center instead of the sterilizer and were not sterilized before distribution.

    Product
    Acufex Access Advanced Positioning Kit - indicated for use to position and distract the extremity of patient during open and arthroscopic surgical procedures Product Number: 72205104
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0602-2022·2022-02-16

    GE Healthcare MRI systems recalled for cryogen ventilation system defect

    GE Healthcare Discovery MR450 MRI systems may have cryogen ventilation systems that do not meet required venting standards. The recall affects approximately 17,228 devices distributed in the U.S. and internationally.

    Product
    GE Healthcare MR superconducting magnets, a component of GE Healthcare Discovery MR450 1.5T system, nuclear magnetic resonance imaging system.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0604-2022·2022-02-16

    GE Healthcare MR Superconducting Magnets Recalled for Ventilation Defect

    GE Healthcare recalled 17,228 superconducting magnets, a component of SIGNA 1.5T MR systems, due to a cryogen ventilation system that may not meet venting requirements. Systems are distributed nationwide and internationally.

    Product
    GE Healthcare MR superconducting magnets, a component of GE Healthcare SIGNA 1.5T TwinSpeed MR System, nuclear magnetic resonance system.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0596-2022·2022-02-16

    GE Healthcare MRI Systems Recalled for Potential Cryogen Ventilation Defect

    GE Healthcare is recalling approximately 17,228 SIGNA Creator and Explorer MRI systems due to potential defects in their cryogen ventilation systems that may not meet required venting standards.

    Product
    GE Healthcare MR superconducting magnets, a component of GE Healthcare SIGNA Creator and SIGNA Explorer System, nuclear magnetic resonance imaging system.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0594-2022·2022-02-16

    GE Healthcare MRI Systems Recalled for Inadequate Cryogen Ventilation

    GE Healthcare is recalling MRI superconducting magnets with cryogen ventilation system defects not meeting safety requirements. The recall affects 17,228 devices distributed across the US and internationally.

    Product
    GE Healthcare MR superconducting magnets, a component of GE Healthcare Discovery MR750 3.0T System, nuclear magnetic resonance imaging system.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0605-2022·2022-02-16

    GE Healthcare MR system magnets recalled due to cryogen ventilation defect

    GE Healthcare is recalling 17,228 MR superconducting magnet components due to a cryogen ventilation system that may not meet required venting specifications.

    Product
    GE Healthcare MR superconducting magnets, a component of GE Healthcare SIGNA Infinity MR System, SIGNA Infinity MR System with Excite Technology, nuclear magnetic resonance imaging system.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0586-2022·2022-02-16

    Diagnostic Control Microorganism Recalled for Incorrect Test Results

    Diagnostic control microorganisms manufactured by Microbiologics Inc are recalled for returning incorrect antibiotic susceptibility test results. These controls failed quality specifications and could cause inaccurate lab test results.

    Product
    LYFO-DISK Enterococcus faecalis derived from ATCC 51299 In Vitro Diagnostic Control microorganisms
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0565-2022·2022-02-16

    MIC Percutaneous Endoscopic Gastrostomy Kits Recalled for Oversized Retention Bolster

    Avanos Medical is recalling the MIC Percutaneous Endoscopic Gastrostomy (PEG) Kit because the external retention bolster may be oversized relative to the tube. Approximately 2,652 units have been distributed in the US, Canada, and Chile.

    Product
    MIC* Percutaneous Endoscopic Gastrostomy PEG Kit - 20 Fr-PULL
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0593-2022·2022-02-16

    GE Healthcare MRI Systems Cryogen Ventilation System Defect Recall

    GE Healthcare is recalling Discovery MR750w 3.0T MRI systems due to cryogen ventilation systems that may not meet FDA venting requirements. Approximately 17,228 devices were affected.

    Product
    GE Healthcare MR superconducting magnets, a component of GE Healthcare Discovery MR750w 3.0T System, nuclear magnetic resonance imaging system.
    Category
    Medical Device
    Distribution
    Distributed nationwide