The Recall Desk

State

American Samoa product recalls

73,738 recalls have nationwide distribution and so reach American Samoa. 25 additional recalls listed American Samoa specifically in their distribution scope.

What the numbers show

Total
25
Critical
1
Severe
9
Most recent
2026-09-09

Of the 25 recalls naming American Samoa we have scored against our rubric, 1 (4%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 9 (36%) are Severe.

Which agencies issued them

These figures cover only the 25 recalls whose distribution notice names American Samoa specifically. The 73,738 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

34301–34325 of 73763

  • SevereUSDA FSIS·042-2019·2019-04-05

    J&J Snack Foods Recalls Stuffed Sandwiches Due to Plastic Contamination

    J&J Snack Foods Handhelds Corp. is recalling Bremer hot stuffed sandwiches due to possible semi-transparent plastic contamination. No illnesses have been reported.

    Product
    J&J Snack Foods Handhelds Corp. — J&J Snack Foods Handhelds Corp. Recalls Stuffed Sandwich Products due to Possible Foreign Matter Contamination
    Category
    Food
    Distribution
    Distributed nationwide
  • HighNHTSA·19V275000·2019-04-05

    Kenworth T680 and T880 Recalled for Parking Brake Signal Delay

    PACCAR is recalling 2018-2020 Kenworth T680 and T880 trucks because a parking brake signal delay in cold weather may cause unexpected vehicle movement.

    Product
    KENWORTH — KENWORTH T680, T880
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V273000·2019-04-04

    BMW Recalls 2006 Models Due to PCV Valve Fire Risk

    BMW is recalling 2006 3, 5, and Z4 series vehicles because a heater in the PCV valve may short circuit, increasing the risk of a fire.

    Product
    BMW — BMW Z4, 530XI, 525I, 325XI
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereUSDA FSIS·041-2019·2019-04-04

    Blount Fine Foods Recalls Chicken Soup for Undeclared Milk Allergen

    Blount Fine Foods is recalling frozen chicken soup products due to misbranding and an undeclared milk allergen. No adverse reactions have been reported.

    Product
    Blount Fine Foods — Blount Fine Foods Recalls Ready-To-Eat Chicken Soup Product due to Misbranding and an Undeclared Allergen
    Category
    Food
    Distribution
    Distributed nationwide
  • HighCPSC·19099·2019-04-04

    Vivitar Recalls Hot/Cold Massage Balls Due to Burn Hazard

    Vivitar is recalling hot/cold massage balls sold at Target because they can leak or rupture during microwaving, posing a burn hazard.

    Product
    Hot/cold massage balls
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • CriticalFDA (Drugs)·D-1085-2019·2019-04-03

    Blue Fusion Capsules Recalled for Undeclared Prescription Ingredients

    Ata International Inc is recalling Blue Fusion Capsules because FDA analysis found undeclared prescription ingredients, including Sildenafil and Tadalafil.

    Product
    Blue Fusion Capsules, 1- count blister pack, Distributed by: DNS Distribution 5225 Canyon Crest Dr. Ste 71-640, Riverside, CA 92507, UPC 7 48252 66460 0
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0986-2019·2019-04-03

    Maquet Cardiohelp Emergency Drive Recalled for Gearwheel Assembly Defect

    Maquet Cardiovascular is recalling 10 units of the Cardiohelp Emergency Drive because the gearwheel may have been incorrectly reassembled, leading to inadequate operation.

    Product
    Cardiohelp Emergency Drive, Part No. 70104.8002 Product Usage: The Cardiohelp Emergency Drive is used in emergencies to manually drive the disposable if the Cardiohelp-i fails.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1053-2019·2019-04-03

    Philips UroDiagnost MRF Recall Due to Missing Locking Plate

    Philips is recalling UroDiagnost MRF units because a missing locking plate may cause unexpected stand or table tilt movement that users cannot stop.

    Product
    Urodiagnost, Product No. 708033 Product Usage: The Philips UroDiagnost MRF can be used to perform all urological and gynecological routine examinations including: Urograms with injection or infusion Retrograde pyelography Cystography and urethrography Micturition…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1054-2019·2019-04-03

    Philips OmniDiagnost X-ray System Recalled for Missing Locking Plate

    Philips North America is recalling 1,696 OmniDiagnost Classic X-ray systems because a missing locking plate may cause unexpected stand or table movement that users cannot stop.

    Product
    Omnidiagnost Classic, Product Codes 70859, 708023, 708024, 708025 Product Usage: The Philips OmniDiagnost is a multi-functional, universal X-ray system with remote-controlled facilities. It performs a wide range of routine examinations and interventional procedures include…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·19V269000·2019-04-03

    Weis Fire & Safety Recalls One 2018 Ford F-550 Emergency Vehicle

    Weis Fire & Safety is recalling one 2018 Ford F-550 emergency vehicle because its brake lights may illuminate without the brake pedal being pressed, potentially confusing other drivers.

    Product
    FORD — FORD F-550
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1066-2019·2019-04-03

    Beaver Visitec Soft Tip Cannula Recall for Missing Protective Sheath

    Beaver Visitec is recalling specific lots of Soft Tip Cannulas because a missing protective sheath may cause the silicone tip to break or detach during eye procedures.

    Product
    BVI Visitec Soft Tip Cannula, 0.8MM .50 x 33mm (25G x 1.3 in). The BVI Soft Tip Cannula is intended to irrigate and/or aspirate ophthalmic solutions and liquids in or out of the eye, and remove materials where appropriate (e.g. retinal, subretinal procedures).
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1068-2019·2019-04-03

    Medical Action Industries Recalls Laparotomy Sponges Due to Sterility Concerns

    Medical Action Industries is recalling specific lots of laparotomy sponges due to a potential lack of sterility assurance. The affected products were distributed nationwide and to Canada and Saudi Arabia.

    Product
    Laparotomy Sponge with the following product description and model numbers: 1. Lap 18X18 XR (5 each/pack, 20 pack/case) - Model Number 300, 450, SM40018, V300; 2. Lap 18X18 XR (5 each/pack, 40 pack/case) - Model Number 400, 404, V400, V450; 3. Lap 18X18 XR w/ring…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1049-2019·2019-04-03

    LW Scientific ZIP IQ Combo Centrifuge Rotor Recall for Breakage Risk

    LW Scientific is recalling ZIP IQ Combo Centrifuges because the hematocrit rotor may break and eject through the housing, posing a safety hazard.

    Product
    LW Scientific ZIP IQ Combo Centrifuge, ZIC-CMBO-2RT3 Rev B Product Usage: used as a general purpose centrifuge to spin down blood in hematocrit tubes with additional rotor to spin other fluids in test tubes (15ml)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1051-2019·2019-04-03

    BD Synapsys Laboratory Software Recalled for Incorrect Test Order Association

    Becton Dickinson is recalling BD Synapsys version 2.1 because it allowed test orders to be associated with incorrect culture records.

    Product
    BD Synapsys Laboratory Solutions Catalog Number:444150 Product Usage: BD Synapsys is a laboratory software solution providing data management and workflow management functionality across clinical diagnostic activities. The software integrates operational and clinical data…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-1210-2019·2019-04-03

    Pillsbury Flour Recalled Due to Potential Salmonella Contamination

    Hometown Food Company is recalling Pillsbury Unbleached All Purpose Flour due to potential Salmonella contamination. The product was distributed nationwide.

    Product
    Pillsbury Unbleached All Purpose Flour Enriched 5Lb paper bag retail. 8 bags per shrink wrapped bale wholesale. UPC "0 5150022241 6" - retail unit UPC "0 5150022241 3" - wholesale bale
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1065-2019·2019-04-03

    Accelerate Pheno System Recalled for Incorrect Meropenem Susceptibility Results

    Accelerate Diagnostics is recalling 81 Accelerate Pheno systems because rare bacterial isolates may generate incorrect meropenem susceptibility results. A software update suppresses these specific results to mitigate risk.

    Product
    Accelerate Pheno system, with Accelerate Pheno System Software 1.2.1 - 1.3.1, PSW000012B Product Usage: The Accelerate Pheno system is intended to measure signal intensity of fluorescent probes bound to nucleic acid in target and non-target organisms and to take time-lapse…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1060-2019·2019-04-03

    GE Healthcare Recalls Integrated ECG Cables Due to Short Circuit Risk

    GE Healthcare is recalling 288 integrated ECG cables that can short circuit during defibrillation, potentially diverting 25% of the energy away from the patient.

    Product
    Integrated ECG cable with 3-lead leadwires labeled as the following: 1. ECG TRUNK CABLE, 3-LD W/ INTEGRATED GRABBER LEAD WIRE, AHA, 3.6 M/12 FT; 2. ECG TRUNK CABLE, 3-LD W/ INTEGRATED GRABBER LEAD WIRE, IEC, 3.6 M/12 FT Product Usage: The reusable ECG trunk cable…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1067-2019·2019-04-03

    Philips MX40 Wearable Monitor Batteries Recalled for Manufacturing Defect

    Philips North America is recalling 40 lithium-ion rechargeable batteries for the MX40 Wearable Monitor due to a manufacturing defect that may affect monitor operation.

    Product
    Lithium-ion Rechargeable Batteries for the Philips MX40 Wearable Monitor REF: 989803176201 - Product Usage: Indicated for use by health care professionals whenever there is a need for monitoring the physiological parameters of patients. Intended for monitoring and recording of…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·19V271000·2019-04-03

    Ford E-150 and Transit Vans Recalled for Wheelchair Lift Defect

    Mobility Specialists is recalling 2014-2017 Ford E-150 and Transit vans with wheelchair lifts that may fail, posing a tipping risk to users.

    Product
    FORD — FORD, MOBILITY SPECIALISTS E-150, TRANSIT, FORD E-150
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1048-2019·2019-04-03

    LW Scientific ZIP IQ PCV Centrifuge Recalled for Rotor Breakage Risk

    LW Scientific is recalling 142 ZIP IQ PCV Centrifuges because the plastic rotor may break and be ejected, posing a safety hazard to technicians.

    Product
    LW Scientific ZIP IQ PCV Centrifuge, ZIC-24HD-75T3 Rev C Product Usage: used as a general purpose centrifuge to spin down blood in hematocrit tubes
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighCPSC·19098·2019-04-03

    Matco Tools Wireless Chargers Recalled Due to Burn Hazard

    Professional Tool Products is recalling Matco Tools wireless chargers because they can overheat and cause burns. Consumers should stop using them and return them for a refund.

    Product
    Matco Tools wireless chargers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1050-2019·2019-04-03

    LW Scientific ZIP IQ Combo Centrifuge Rotor Recall for Breakage Hazard

    LW Scientific is recalling 16 ZIP IQ Combo Centrifuges because the hematocrit rotor may break and eject through the housing, posing a safety hazard to technicians.

    Product
    LW Scientific ZIP IQ Combo Centrifuge, ZIC-CMBO-4RT3 Rev B Product Usage: used as a general purpose centrifuge to spin down blood in hematocrit tubes with additional rotors to spin other fluids in test tubes (15ml and 50ml), microtubes, and PCR strips
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1055-2019·2019-04-03

    Philips MultiDiagnost Eleva Imaging System Recalled for Missing Locking Plate

    Philips is recalling MultiDiagnost Eleva imaging systems because a missing locking plate may cause unexpected stand or table tilt movement that users cannot stop.

    Product
    MultiDiagnost Eleva w/ Flat Detector, Product codes 708034, 708037, 708038 Product Usage: As a multifunctional I universal imaging application system, General RIF, Fluoroscopy, Radiography and Angiography can be performed along with more specialized interventional…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1059-2019·2019-04-03

    Fenwal CATSmart Vacuum Unit Recalled for Potential Failure During Use

    Fenwal Inc is recalling 198 Vacuum Units for the CATSmart system because they may stop working and display a failure message during use.

    Product
    Vacuum Unit for CATSmart Vacuum Pump. Fresenius CATSmart (Continuous Autotransfusion System) is indicated for the processing of blood collected intraoperatively and postoperatively to obtain washed packed red blood cells for reinfusion.
    Category
    Medical Device
    Distribution
    Distributed nationwide