Severity 3 (High) recalls have a known hazard but no confirmed illness, injury, or property damage in the source text. The risk is theoretical-but-real: a pathogen pre-emptively pulled from shelves before anyone got sick, an allergen mislabeling on an uncommon allergen, a precautionary correction on a device that hasn't yet malfunctioned in the field. Most allergen recalls land here, as do most preventive food recalls based on routine sampling. You should still stop using the product, but you don't need to panic.

The full rubric is on the methodology page. Severity is computed deterministically from the agency’s own classification plus the source text — no editorial vibes.

26751–26775 of 50462

  • HighFDA (Devices)·Z-0588-2019·2018-12-19

    GE LOGIQ E10 Ultrasound System Recalled for Potential Burn Injury

    GE Healthcare is recalling 103 LOGIQ E10 Ultrasound Systems because a trans-esophageal probe may overheat, posing a risk of burn injury to patients.

    Product
    GE LOGIQ E10 Ultrasound System, Model #530000E10. The device is intended for use by a qualified physician for ultrasound evaluation of Fetal/Obstetrics; Abdominal; Pediatric; Small Organ (breast, testes, thyroid); Neonatal Cephalic; Adult Cephalic; Cardiac (adult and…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·18V897000·2018-12-19

    Seagrave Recalls 2017-2018 Emergency Vehicles for Brake Light Defect

    Seagrave is recalling 2017-2018 Capital and Marauder II emergency vehicles because Whelen accessory brake lights may falsely illuminate, increasing crash risk.

    Product
    SEAGRAVE — SEAGRAVE MARAUDER II, CAPITAL
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·19052·2018-12-18

    TerraTrike Rambler E.V.O. Adult Tricycles Recalled for Crash Hazards

    TerraTrike is recalling about 450 Rambler E.V.O. adult tricycles because the torque sensor can activate unexpectedly, causing the trike to power forward and posing crash and injury hazards.

    Product
    TerraTrike Rambler E.V.O adult tricycles
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·18V925000·2018-12-18

    Triple E Recalls 2019 Serenity RVs Due to Battery Fire Risk

    Triple E is recalling 2019 Serenity recreational vehicles because a metal cable may contact the battery terminal, creating a fire hazard.

    Product
    TRIPLE E — TRIPLE E SERENITY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·18V896000·2018-12-17

    Heartland Milestone Recalled for Improperly Secured Propane Hose

    Heartland is recalling 2019 Milestone trailers because a propane hose may be improperly secured, posing a fire risk if it contacts the tire.

    Product
    HEARTLAND — HEARTLAND MILESTONE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·18V892000·2018-12-17

    Blue Bird Recalls 2017-2019 Vision School Buses for Air Compressor Belt Defect

    Blue Bird is recalling 2017-2019 Vision school buses with specific Cummins engines because a slipping air compressor belt may cause the parking brake to apply while driving, increasing crash risk.

    Product
    BLUE BIRD — BLUE BIRD VISION
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·18V891000·2018-12-14

    Hyundai Recalls 2018 Elantra GT for Sunroof Obstacle Detection Defect

    Hyundai is recalling 2018 Elantra GT vehicles because the panoramic sunroof motor may be incorrectly programmed, preventing it from detecting obstacles while closing.

    Product
    HYUNDAI — HYUNDAI ELANTRA GT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·19050·2018-12-13

    TJX Recalls Glass and Ceramic Drawer Knobs Due to Laceration Hazard

    TJX is recalling glass and ceramic drawer knobs sold at T.J. Maxx, Marshalls, and HomeGoods because they can shatter when pulled, posing a laceration hazard.

    Product
    Glass and ceramic drawer knobs
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·18V890000·2018-12-13

    Frazer Recalls 2017-2018 Ambulances Due to Brake Light Wiring Issue

    Frazer is recalling 2017-2018 Type 1 and Type 3 ambulances and Mobile Stroke Units because Whelen accessory brake lights may illuminate without the brake pedal being pressed.

    Product
    FRAZER — FRAZER TYPE 1 AMBULANCE, TYPE 3 AMBULANCE, MOBILE STROKE UNIT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0532-2019·2018-12-12

    Zimmer Biomet Recalls Humeral Guide Wires Due to Sterility Compromise

    Zimmer Biomet is recalling 780 Humeral Guide Wires because creases in the packaging may compromise sterility. The product is a single-use surgical instrument.

    Product
    Zimmer M/DN¿ Intramedullary Fixation Humeral Guide Wire - Bullet Tip, 2.4 mm Diameter, 70 cm Length Item Number: 00-2255-026-00 Product Usage: A single use surgical instrument used during orthopaedic surgery for implantation of a prosthesis.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0551-2019·2018-12-12

    Capintec Recalls Captus 700 Thyroid Uptake Systems Due to Spring Arm Failure

    Capintec Inc is recalling 65 Captus 700 Thyroid Uptake Systems because a broken tension rod can cause the spring arm to fail and the collimator to fall.

    Product
    Captus 700 Thyroid Uptake System, Model # 5430-3137 and 5430-3138
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0538-2019·2018-12-12

    Zimmer Biomet Recalls Natural Nail System Guide Wires Due to Sterility Compromise

    Zimmer Biomet is recalling 57,241 Natural Nail System Tear Drop Guide Wires because creases in the sealing area may compromise product sterility.

    Product
    Zimmer Natural Nail¿ System - Tear Drop Guide Wire, 3.0 mm Diameter, 100 cm Length Item Number: 47-2490-097-00 Product Usage: A single use surgical instrument used during orthopaedic surgery for implantation of a prosthesis.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0542-2019·2018-12-12

    Zimmer Biomet Recalls Pressure Sentinel Guide Wires Due to Sterility Compromise

    Zimmer Biomet is recalling 1,676 Pressure Sentinel Guide Wires because creases in the packaging seal may compromise sterility. The defect could increase the risk of infection during orthopaedic surgery.

    Product
    Zimmer Pressure Sentinel¿ Intramedullary Reaming System, Guide Wire, Bullet Tip, 2.4 mm Diameter Item Number: 00-2228-024-00 Product Usage: A single use surgical instrument used during orthopaedic surgery for implantation of a prosthesis.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0558-2019·2018-12-12

    Siemens Artis Zee and Zeego X-ray Systems Recalled for Cooling Hose Leak

    Siemens is recalling 64 Artis Zee and Zeego angiography systems due to a possible cooling hose leak that can cause the X-ray tube to overheat and block imaging.

    Product
    Artis Zee and Zeego, model no. 10272462 AXIOM Artis zee/Zeego is a family of dedicated angiography systems developed for single and biplane diagnostic imaging and interventional procedures including, but not limited to, pediatric and obese patients.
    Category
    Medical Device
    Distribution
    12 states
  • HighFDA (Devices)·Z-0560-2019·2018-12-12

    Atrium Medical Recalls 28Fr Thoracic Catheters Due to Seal Defect

    Atrium Medical Corporation is recalling 2,930 units of 28Fr PVC Thoracic Catheters due to a seal defect in sterile barrier pouches that could compromise sterility.

    Product
    Atrium 28Fr PVC Thoracic Catheter RIGHT ANGLE, Part No. 8128
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0534-2019·2018-12-12

    Zimmer Biomet Recalls Guide Wires Due to Sterility Compromise

    Zimmer Biomet is recalling 9,387 units of ZMS Intramedullary Fixation Smooth Guide Wires because creases in the sealing area compromise product sterility.

    Product
    Zimmer ZMS¿ Intramedullary Fixation Smooth Guide Wire, 3.0 mm Diameter, 100 cm Length Item Number: 47-2237-037-00 Product Usage: A single use surgical instrument used during orthopaedic surgery for implantation of a prosthesis.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0545-2019·2018-12-12

    Philips Brilliance 16 Slice CT Scanner Recalled for Gantry Cover Separation Risk

    Philips Medical Systems is recalling 6,343 Brilliance 16 Slice CT scanners nationwide due to a potential fiberglass resin separation that could cause the gantry front cover to fall.

    Product
    Brilliance 16 Slice (Power), Model 728240 Product Usage: Computed Tomography X-ray systems intended to produce cross-sectional Images of the body by computer reconstruction of X-ray transmission data taken at different angles and planes. These devices may include signal…
    Category
    Medical Device
    Distribution
    Distributed nationwide