The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

4901–4925 of 90255

  • HighFDA (Devices)·Z-0504-2026·2025-11-26

    Luer tip caps recalled after trays failed routine biocompatibility testing

    Becton Dickinson is recalling 4,180,000 BD Luer Tip Caps after internal testing confirmed that certain device trays failed routine biocompatibility testing.

    Product
    BD Luer Tip Caps; Catalog Number(s) or Model Number(s): 308341;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0524-2026·2025-11-26

    Gynecology and robotic kits recalled over smoke pencils that may self activate

    Medline is recalling 2,844 gynecology laparoscopy and robotic convenience kits containing SafeAir Smoke Evacuation Pencils, after Stryker expanded its recall of the pencils by 47 lots.

    Product
    MEDLINE convenience kits labeled as: 1) GYN LAPAROSCOPY CDS #34-RF, REF CDS920099S; 2) GYN LAPAROSCOPY CDS-LF, REF CDS983764J; 3) ROBOTIC, REF CDS984262N; 4) ROBOTIC, REF CDS984262P; 5) ROBOTIC UROLOGY-RF, REF DYNJ38844N; 6) DA VINCI PROSTATE/COLPOPEXY, REF…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0507-2026·2025-11-26

    Heart pump implant kits recalled over corrosion at the battery connector

    Thoratec is recalling 248 HeartMate II LVAS Implant Kits because potential corrosion at the backup battery cable connector may cause a Backup Battery Fault Alarm.

    Product
    Brand Name: HeartMate Product Name: HeartMate II¿ LVAS Implant Kit Model/Catalog Number: 106015, HeartMate II¿ LVAS Kit, with Pocket Controller, Sealed, US; 106016, HeartMate II¿ LVAS Kit, with Pocket Controller, Sealed, EU Software Version: N/A Product Description: The…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0503-2026·2025-11-26

    Oncology software recalled because appended medication orders may mismatch the schedule

    Elekta is recalling four systems running MOSAIQ Oncology Information System builds 3.1.3 through 3.2.3.0 because appended wave medication orders may not match the intended schedule.

    Product
    MOSAIQ Oncology Information System Software Builds 3.1.3, 3.2.1, 3.2.2 & 3.2.3.0 Software Version and UDI Codes: 3.1.3.0 (01)07340201500026(10)3.1.3.0 3.1.3.1 (01)07340201500026(10)3.1.3.1 3.1.3.2 (01)07340201500026(10)3.1.3.2 3.1.3.3 (01)07340201500026(10)3.1.3.3…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0518-2026·2025-11-26

    Port insertion packs recalled over smoke pencils that may stay live

    Medline is recalling 12 Port Insertion Pack convenience kits containing SafeAir Smoke Evacuation Pencils, after Stryker expanded its recall of the pencils by 47 lots.

    Product
    MEDLINE convenience kits labeled as: PORT INSERTION PACK, REF DYNJ81597
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0540-2026·2025-11-26

    Bone void implants recalled over an incorrect product name on packaging

    Berkeley Advanced Biomaterials is recalling 62 Tribio Implants 7.5mm x 40mm because the outer packaging carries an incorrect product name.

    Product
    Tribio Implant 7.5mm x 40mm REF M80 SB008 UDI code: (01) 00816125023653(10) EBL10B13C(17) 270630 Tribio" Implant is indicated for use in bony voids or gaps of the skeletal system (i.e. extremities, pelvis and posterolateral spine). These osseous defects are surgically…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0508-2026·2025-11-26

    HeartMate II controllers recalled over corrosion at the battery connector

    Thoratec is recalling 2,424 HeartMate II Pocket Controllers because potential corrosion at the backup battery cable connector may cause a Backup Battery Fault Alarm.

    Product
    Brand Name: HeartMate Product Name: HeartMate II¿ Controller (standalone) Model/Catalog Number: 106017, HeartMate II¿ Pocket Controller, US; 106762, HeartMate II¿ Pocket Controller, US; 107801, HeartMate II¿ Pocket Controller Software Version: N/A Product Description: The…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0572-2026·2025-11-26

    Nephrostomy balloon kits recalled after containing the wrong sized catheter

    Olympus is recalling 60 Nephro-EZDilate nephrostomy balloon catheter kits because they contained a 4mm x 4cm urinary tract balloon instead of the correct 8mm x 15cm nephrostomy balloon.

    Product
    Brand Name: EZDilate Nephrostomy Balloon Catheter and Inflation Device Kit Product Name: Olympus Nephro-EZDilate Nephrostomy Balloon Catheter Model/Catalog Number: BPCN0815K Product Description: The Nephro-EZDilate nephrostomy balloon catheter is a reinforced catheter…
    Category
    Medical Device
    Distribution
    6 states
  • HighFDA (Devices)·Z-0514-2026·2025-11-26

    Central line and flap packs recalled over smoke pencils that may activate

    Medline is recalling 142 central line and free flap convenience packs containing SafeAir Smoke Evacuation Pencils, after Stryker expanded its recall of the pencils by 47 lots.

    Product
    MEDLINE convenience kits labeled as: 1) CENTRAL LINE PACK, REF DYNJ00281P; 2) FREE FLAP PACK, REF DYNJ68213C.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0521-2026·2025-11-26

    General surgery and knee kits recalled over smoke pencil activation defect

    Medline is recalling 20,941 general surgery, laparoscopy and total knee convenience kits containing SafeAir Smoke Evacuation Pencils, after Stryker expanded its recall by 47 lots.

    Product
    MEDLINE convenience kits labeled as: 1) GENERAL LAPAROSCOPY, REF CDS930027W; 2) GENERAL MAJOR CDS, REF CDS980245X; 3) BASIC GENERAL CDS, REF CDS980566F; 4) TOTAL KNEE CDS, REF CDS982823R; 5) BASIC CDS, REF CDS982936U; 6) UPPER EXTREMITY CDS, REF CDS983907M; 7)…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0509-2026·2025-11-26

    ECMO consoles recalled after eleven reports of a blank touchscreen error

    Medtronic is recalling 167 MC3 VitalFlow Consoles after eleven reports of an E70 error code that leaves the touchscreen blank for up to two minutes during operation.

    Product
    MC3 VitalFlow Console, REF 58100; Blood pump of ecmo
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0527-2026·2025-11-26

    Gynecology surgery kits recalled over smoke pencils that may activate

    Medline is recalling 570 gynecology laparotomy, lithotomy and hysterectomy convenience kits containing SafeAir Smoke Evacuation Pencils, after Stryker expanded its recall by 47 lots.

    Product
    MEDLINE convenience kits labeled as: 1) GYN LAPAROTOMY HARPER PACK-LF, REF DYNJ0160684F; 2) MAJOR LITHOTOMY PACK-LF, REF DYNJ0425778O; 3) MINOR VAGINAL #76-RF, REF DYNJ27434R; 4) ABDOMINAL HYST PACK, REF DYNJ44848M; 5) DA VINCI HYSTERECTOMY, REF DYNJ44863Q; 6)…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0520-2026·2025-11-26

    Basin packs recalled over smoke pencils that may activate unprompted

    Medline is recalling 1,921 basin convenience packs containing SafeAir Smoke Evacuation Pencils, after Stryker expanded its recall of the pencils by 47 lots.

    Product
    MEDLINE convenience kits labeled as: 1) MINOR SINGLE BASIN PACK, REF DYNJ37698L; 2) BASIN PACK, REF DYNJ50123D; 3) MAJOR BASIN PACK, REF DYNJ59816A; 4) OSC BASIN PACK, REF DYNJ68217A.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V817000·2025-11-25

    International truck control units can lose ABS and stability control

    International is recalling certain 2016-2026 trucks with Bendix control units because electrical noise may cause the ECU to misprocess commands or stop working, disabling ABS and stability control.

    Product
    INTERNATIONAL — INTERNATIONAL 8600, HV, HX, LONESTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V816000·2025-11-25

    Rivian delivery van driver seat belt pretensioner cable can be damaged

    Rivian is recalling certain 2022-2025 EDV vehicles because the driver's seat belt pretensioner cable may become damaged and fail to restrain the occupant as intended in a crash.

    Product
    RIVIAN — RIVIAN EDV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V818000·2025-11-25

    Volvo Recalls XC60 Models Due to Improperly Tightened Front Seat Bolts

    Volvo is recalling 2018, 2025, and 2026 XC60 vehicles because front seat bolts may be loose. This defect could prevent seats from restraining occupants during a crash.

    Product
    VOLVO — VOLVO XC60MHEV, XC60
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V819000·2025-11-25

    2026 Cadillac Vistiq Electric Vehicles Missing Owner's Manual

    General Motors is recalling certain 2026 Cadillac Vistiq electric vehicles because the radio may not have been configured to download the electronic owner's manual during production. Without access to the manual, owners may not know how to safely use and operate the vehicle.

    Product
    CADILLAC — CADILLAC VISTIQ
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V812000·2025-11-24

    Newell Recalls 2022 P50 Coaches Due to Seat Mounting Defect

    Newell Coach Corp. is recalling 2022 P50 coaches because improperly welded pedestal mounting plates may cause seat assemblies to detach, increasing crash injury risk.

    Product
    NEWELL — NEWELL P50
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V813000·2025-11-24

    Foretravel Recalls Realm and Realm 450 Vehicles for Seat Weld Defect

    Foretravel is recalling 2020-2022 Realm and 2022 Realm 450 vehicles because a seat mounting plate may be improperly welded, allowing the seat to detach.

    Product
    FORETRAVEL — FORETRAVEL REALM, REALM 450
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V814000·2025-11-24

    nuCamp Trailers Recalled for Incorrect Weight Labels

    Pleasant Valley is recalling 2025-2026 nuCamp trailers because incorrect weight information on labels may lead to unintentional overloading and increased crash risk.

    Product
    NUCAMP — NUCAMP TAB 320, TAB 360, TAB 400, TAG
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V810000·2025-11-21

    Altec Recalls 2019-2024 AT Series Vehicles Due to Emergency Stop Defect

    Altec is recalling 2019-2024 AT Series vehicles because the lower emergency stop may not function when the upper control is selected, increasing the risk of death or serious injury.

    Product
    ALTEC — ALTEC AT SERIES
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereCPSC·26096·2025-11-20

    Folding learning towers recalled after 14 reports of the platform collapsing

    About 9,780 Grow 'N Stow Folding Learning Towers are being recalled because the platform inside the tower can collapse; 14 collapses have been reported including one child with bruises.

    Product
    Grow 'N Stow Folding Learning Tower
    Category
    Consumer Product
    Distribution