The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

28626–28650 of 39756

  • SevereFDA (Drugs)·D-0428-2015·2015-04-08

    Baxter Recalls Clinimix E Due to Sterility Assurance Concerns

    Baxter Healthcare is recalling 7,444 containers of Clinimix E 5/20 due to a lack of assurance of sterility and increased leak complaints.

    Product
    CLINIMIX E — CLINIMIX E (LEUCINE, PHENYLALANINE, LYSINE, METHIONINE, ISOLEUCINE, VALINE, HISTIDINE, THREONINE, TRYPTOPHAN, ALANINE, GLYCINE, ARGININE, PROLINE, SERINE, TYROSINE, DIBASIC POTASSIUM PHOSPHATE, MAGNESIUM CHLORIDE, SODIUM CHLORIDE, CALCIUM CHLORIDE, DEXTROSE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1786-2015·2015-04-08

    Spice N' More Recalls Cumin Powder for Undeclared Peanut

    Spice N' More Corp. is recalling various brands of cumin powder because the product may contain undeclared peanut protein.

    Product
    Cumin Powder (comino molido) Various brands: 1) Key Food Quality Natural Spices , NET WT. 12 oz., UPC 073296001440; 2.)La Mina" Quality Natural Spices NET WT. 12 oz., UPC 818685010517; 3) Salma Natural Cumin NET WT. 12 oz., UPC 023913159085; 4.) Spice Class All Natural Cumin…
    Category
    Food
    Distribution
    8 states
  • SevereFDA (Devices)·Z-1362-2015·2015-04-08

    Pega Medical Recalls GAP Nail 4.8mm Due to Distal Screw Hole Failures

    Pega Medical Inc. is recalling 7 units of the 4.8mm GAP Nail because of failures at the distal cortical screw holes, primarily in patients with specific bone conditions.

    Product
    GAP Nail 4.8mm (diameter size) of the GAP ENDO-EXO MEDULLARY SYSTEM. Catalog number GAP-N48-16; GAP-N48-18; GAP-N48-26; GAP-N48-28. Product Usage: The GAP Endo-Exo Medullary System is used for the treatment of fractures or correction of deformities in the femur, tibia and…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1356-2015·2015-04-08

    Medtronic Temporary Pacemaker Recalled for Battery Connection Failure

    Medtronic is recalling 6,040 Model 5392 temporary pacemakers because specific AA batteries may fail to connect, potentially stopping pacing therapy.

    Product
    Medtronic Dual Chamber Temporary External Pacemaker, Model 5392. Product Usage: The temporary pacemaker is used with a cardiac pacing lead system for temporary single or dual chamber pacing in a clinical environment by trained personnel. The temporary pacemaker can be used…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1874-2015·2015-04-08

    Healthy Mama Protein Drink Recalled for Undeclared Milk Allergen

    Maternal Science Inc. is recalling Healthy Mama Boost It Up Mighty Mango Protein Drink because it contains undeclared milk.

    Product
    Healthy Mama Boost It Up Mighty Mango Caffeine Free Protein with Energy Drink 12 fl oz Distributed by: Maternal Science, Inc. 50 Tice Boulevard, Suite 340 Woodcliff Lake, NJ 07677 UPC 810758020058
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1863-2015·2015-04-08

    Tres Leches Cake Recalled for Undeclared Soy Allergen

    AL'S PICADERA is recalling Tres Leches Cake because the label fails to declare soy as an ingredient. The product was distributed in Puerto Rico.

    Product
    LBL reads in part:*** AL'S PICADERA*** MANTENGASE REFRIGERADO ENTREMESES & POSTRES*** 3 LECHES***"
    Category
    Food
    Distribution
    1 state
  • SevereFDA (Food)·F-1795-2015·2015-04-08

    Ground Cumin Recalled for Undeclared Peanut Protein

    The Spicemill LLC is recalling 99 bottles of Ground Cumin in Connecticut due to undeclared peanut protein.

    Product
    Cumin Ground, 2.75 oz., UPC: 811267012008. Product is packaged in a plastic bottle with a black flip-top lid.
    Category
    Food
    Distribution
    1 state
  • SevereFDA (Food)·F-1784-2015·2015-04-08

    Fiesta Pacific Recalls Horchata Syrup Due to Bacterial Growth Risk

    Fiesta Pacific is recalling Brown Label Horchata Post Mix Fountain Syrup because a formulation error and lack of preventive processes allow potentially harmful bacteria, including Clostridium botulinum, to grow.

    Product
    Horchata Post Mix Fountain Syrup, 3 gallons (11.4 Liters), UPC 0 09319 00006 0.
    Category
    Food
    Distribution
    5 states
  • SevereFDA (Food)·F-1803-2015·2015-04-08

    My Spice Sage Ground Cumin Recalled for Undeclared Peanut

    Zenobia Company LLC is recalling My Spice Sage Ground Cumin because it may contain undeclared peanut protein. The recall covers 1,467 units sold nationwide.

    Product
    My Spice Sage CUMIN GROUND under the following labels and packaging: 1) NET WT 1 oz (28g) UPC 00105001, packed in a plastic resealable bag 2) NET WT 4 oz (113g) UPC 00105004 packed in a plastic resealable bag, 3) NET WT 4.9 oz (139g) UPC 00105000 packed in a plastic bottle, 4)…
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1872-2015·2015-04-08

    Healthy Mama Boost It Up Protein Drink Recalled for Undeclared Milk

    Maternal Science Inc. is recalling Healthy Mama Boost It Up Mango with Ginger Protein Drink because it contains undeclared milk.

    Product
    Healthy Mama Boost it Up Mango with Ginger Caffeine Free Protein with Energy Drink 12 fl oz Distributed by: Maternal Science, Inc. 50 Tice Boulevard, Suite 340 Woodcliff Lake, NJ 07677 UPC 810758020058
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V210000·2015-04-08

    KTM Recalls 2015 690 Enduro R Motorcycles Due to Rear Brake Line Damage

    KTM is recalling 409 model year 2015 690 Enduro R motorcycles because the rear brake line may be damaged, potentially causing a loss of braking ability and increasing crash risk.

    Product
    KTM — KTM 690 ENDURO R
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1794-2015·2015-04-08

    Adkins Barbecue Spice Recalled Due to Recalled Cumin Ingredient

    American Spice & Seasoning, Inc. is recalling Adkins Barbecue Spice because it contains cumin from a recalled supplier.

    Product
    Adkins Barbecue Spice Net Wt. 25 lbs. UPC: 0-77139-21382-3
    Category
    Food
    Distribution
    2 states
  • SevereFDA (Devices)·Z-1370-2015·2015-04-08

    BD FACSCalibur Instruments Recalled for Incorrect Circuit Breaker Amperage

    BD Biosciences is recalling 72 BD FACSCalibur instruments because some have circuit breakers with incorrect amperage ratings, which may fail to open during over-current situations.

    Product
    BD FACSCalibur; Catalog Numbers 342973, 342975, 34976 In vitro Diagnostics Use.
    Category
    Medical Device
    Distribution
    3 states
  • SevereFDA (Food)·F-1790-2015·2015-04-08

    Archer Farms Ground Cumin Recalled for Undeclared Peanut Allergen

    Brinkhoff & Monoson Inc is recalling Archer Farms ground cumin because it may contain undeclared peanut allergens.

    Product
    Archer Farms Cumin, ground, packaged in 6 oz clear square glass bottle with a silver metal cap and a label weight of 2.8oz (79 g), Distributed by Target Corp. Minneapolis, MN;
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1793-2015·2015-04-08

    Prima Spice Recalls Ground Cumin Jugs Due to Peanut Contamination

    Prima Spice, Inc. is recalling Chef's Delight Ground Cumin 5.0 lb jugs due to possible peanut protein contamination.

    Product
    Chef's Delight Spices & Herbs - Ground Cumin, Net Wt. 5.0 lb Jugs, Packed for Hermolia, Packed by CO, Brooklyn, NY
    Category
    Food
    Distribution
    0 states
  • SevereFDA (Food)·F-1789-2015·2015-04-08

    Brinkhoff & Monoson Dark Chili Powder Recalled for Undeclared Peanut Allergen

    Brinkhoff & Monoson is recalling Dark Chili Powder distributed by The Fresh Market because it contains cumin that may be contaminated with undeclared peanut allergens.

    Product
    Dark Chili Powder packaged in the following configurations: (1) a 5 by 7 in clear square bag with a zipper seal and a label weight of 2.24 oz (63.5 g), Distributed by The Fresh Market, Greensboro, NC, and (2) 4 oz clear square glass bottle with a silver metal cap and a label…
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1806-2015·2015-04-08

    Gilster-Mary Lee Recalls Honey & Oat Mixers Cereal for Undeclared Almonds

    Gilster-Mary Lee Corp. is recalling Honey & Oat Mixers dry cereal because it contains undeclared almonds, a major food allergen.

    Product
    Honey & Oat Mixers ready-to-eat dry cereal sold under the market pantry brand and packaged in card stock cartons with a new weight of 18 oz. (1 lb. 2 oz.) 510 g.
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1357-2015·2015-04-08

    DePuy RECLAIM Hip Implant Inserter Adaptor Recalled for Fracture Risk

    DePuy Orthopaedics is recalling 54 units of the RECLAIM Assembled Implant Inserter Adaptor because the instrument may fracture during surgery, potentially leaving plastic pieces in the patient.

    Product
    RECLAIM Assembled Implant Inserter Adaptor orthopedic manual surgical instrument for hip implantation.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereUSDA FSIS·056-2015·2015-04-08

    Vern's and Sons Recalls Beef and Chicken Burritos Produced Without Inspection

    Vern's and Sons Food Service is recalling approximately 450 pounds of beef and chicken burritos produced without federal inspection. The products were shipped to retail locations in Oregon and Washington.

    Product
    Vern's and Sons Food Service Recalls Beef and Chicken Products Produced Without Benefit of Inspection
    Category
    Food
    Distribution
    2 states
  • SevereFDA (Food)·F-1873-2015·2015-04-08

    Healthy Mama Protein Drink Recalled for Undeclared Milk Allergen

    Maternal Science Inc. is recalling 60 units of Healthy Mama Boost it Up Pom Cherry Caffeine Free Protein with Energy Drink because it contains undeclared milk.

    Product
    Healthy Mama Boost it Up Pom Cherry Caffeine Free Protein with Energy Drink 12 fl oz Distributed by: Maternal Science, Inc. 50 Tice Boulevard, Suite 340 Woodcliff Lake, NJ 07677 UPC 810758020126
    Category
    Food
    Distribution
    Distributed nationwide