The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

6726–6750 of 27393

  • HighFDA (Devices)·Z-0396-2024·2023-11-29

    Boston Scientific EXALT Model D Duodenoscope Recall: Fluid Ingress in Lens

    Boston Scientific is recalling certain EXALT Model D Single-Use Duodenoscopes worldwide due to fluid ingress in the lens, which causes poor image quality. Affected devices should not be used; contact the manufacturer.

    Product
    EXALT Model D Single-Use Duodenoscope: Outer box UPN# M00542420 & Outer box UPN# M0054242CE0.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0333-2024·2023-11-29

    Gastroscope Devices Recalled for Inadequate Channel Drying Process

    Aizu Olympus recalls 680 gastroscope-EUS devices due to unvalidated channel drying. Water remaining in the channels poses contamination and infection risks.

    Product
    Gastroscope-endoscopic ultrasound (EUS) guided fine needle aspiration (FNA) and for endoscopic surgery within the upper digestive tract. Model Numbers: GF-UC140P-AL5, GF-UCT180, GF-UE160-AL5.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0342-2024·2023-11-29

    Sigmoidovideoscope models recalled due to improper channel drying process

    Aizu Olympus sigmoidovideoscope (model PCF-S) units are being recalled due to an unvalidated channel drying process. Some repaired units returned with water in channels, risking contamination and infection.

    Product
    Signmoidovideoscope-For endoscopy and endoscopic surgery within the lower digestive tract (including the anus, rectum and sigmoid colon). Model Number: PCF-S.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0346-2024·2023-11-29

    Olympus endoscopes recalled for potential water contamination in channels

    Aizu Olympus Co., Ltd. is recalling duodenovideoscope models due to an unvalidated channel air drying process. Water remaining in the channels after repair poses a potential contamination risk that could lead to infection.

    Product
    Duodenovideoscope-EndoTherapy accessories (such as a biopsy forceps), and other ancillary equipment for endoscopy and endoscopic surgery Model Numbers: TJF-145, TJF-150, TJF-Q180V, TJF-Q190V.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0345-2024·2023-11-29

    Ultrasonic Gastrovideoscope Model TGF-UC180J Recalled for Inadequate Channel Drying

    Aizu Olympus is recalling ultrasonic gastrovideoscopes due to an unvalidated channel drying process that left some scopes with water in the channels after repair. Water remaining in the device poses a risk of contamination and infection.

    Product
    Ultrasonic gastrovideoscope-Real time ultrasound imaging,ultrasound guided needle aspiration and other endoscopic procedures within the upper gastrointestinal tract and surrounding organs Model Number: TGF-UC180J.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0387-2024·2023-11-29

    Biomet Compress Device Short Anchor Plug recalled for metal burrs

    Biomet is recalling the Compress Device Short Anchor Plug due to metal burrs in transverse holes that may prevent proper insertion of drill or pins, potentially extending surgical time. No injuries have been reported.

    Product
    Compress Device Short Anchor Plug, 26 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178568
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0360-2024·2023-11-29

    Avanos BALLARD Closed Suction System mislabeled for DEHP content

    Certain lots of AVANOS BALLARD Closed Suction System for Adults were labeled as DEHP-free but contain DEHP in tubing components. These units are used for mechanical ventilation and distributed in the US and South Africa.

    Product
    AVANOS BALLARD Closed Suction System for Adults, 14 Fr, DSE, MDI, Product code 221038, provide suction on patients on mechanical ventilation
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0331-2024·2023-11-29

    Endoscopic surgical instruments recalled for unvalidated drying process

    Aizu Olympus is recalling cystonephroscope endoscopes due to an unvalidated air drying process that allowed water to remain in instrument channels. Retained moisture poses a risk of contamination and infection.

    Product
    Cystonephroscope-endoscopic diagnosis and treatment within the bladder, urethra, and kidney Model Numbers: CYF-5, CYF-VH, CYF-VHR.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0373-2024·2023-11-29

    Biomet Compress Device Segmental Anchor Plugs Recalled for Metal Burrs

    Biomet has recalled certain Compress Device Segmental Anchor Plugs (16 MM) due to metal burrs in the transverse holes. These burrs may prevent the drill or pins from passing through, potentially extending surgical time.

    Product
    Compress Device Segmental Anchor Plug, 16 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178406
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0320-2024·2023-11-29

    Medtronic Mo.Ma Ultra cerebral protection device labeling error recalled

    Medtronic is recalling 2,767 units of the Mo.Ma Ultra Proximal Cerebral Protection Device due to labeling errors on the manifold that result in incorrect identification of inflation and deflation ports.

    Product
    Medtronic Mo.Ma Ultra Proximal Cerebral Protection Device, Model Number MUS0130069X6
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0306-2024·2023-11-22

    Philips Spectral CT on Rails Software Crash During Fluoroscopy Operations

    Philips is recalling the Spectral CT on Rails (Model 728334, Software Version 5.1.0) due to a software crash that occurs when CCT Fluoroscopy mode and foot pedal are activated simultaneously. The crash requires system restart.

    Product
    Spectral CT on Rails, Software Version 5.1.0, Model Number 728334
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0292-2024·2023-11-22

    Philips Big Bore RT CT Scanner Defect May Cause Incorrect Treatment Planning

    A software defect in Philips Big Bore RT CT scanners may cause incorrect coordinates in radiation therapy planning systems, affecting 56 units distributed nationwide and internationally.

    Product
    Big Bore RT with software version V4.8.0.10421- Model: 728242 CT scanner and simulator designed for radiation oncology and therapy.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0308-2024·2023-11-22

    Laboratory Culture Disks Recalled for Aspergillus Flavus Contamination

    Microbiologics Inc is recalling LYFO-DISK P. venetum laboratory culture disks (lot 794-142) found contaminated with Aspergillus flavus during complaint investigation. The product was distributed worldwide.

    Product
    LYFO-DISK, P. venetum, Catalog number 0794L
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0291-2024·2023-11-22

    Atrium Advanta V12 Covered Stent System Recalled for Weld Failure

    Atrium Medical Corporation is recalling 141 units of the Advanta V12 Covered Stent System due to a balloon-to-catheter weld failure that may cause loss of balloon pressure during stent deployment. Affected units were distributed to eleven countries.

    Product
    Atrium Advanta V12 Covered Stent System, 10mm x 59mm x 80cm (OUS)-Indicated for restoring and improving the patency of the iliac andrenal arteries. Renal approval includes 5mm, 6mm and 7mm diameter Advanta V12 covered stent sizes. In Canada, the Advanta V12 Covered Stent indicat
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0298-2024·2023-11-22

    LIFEPAK 15 Defibrillator Recall: Loose Battery Pins May Cause Power Failure

    Physio-Control is recalling LIFEPAK 15 defibrillators due to loose battery pins that may cause power failure. Users should verify device functionality immediately.

    Product
    LIFEPAK 15, REF: 99577-000061, Part Number V15-2-000067
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0312-2024·2023-11-22

    Medline Recalls Central Line Blood Culture Kits Over Expired Components

    Medline Industries is recalling 1,600 Central Line Blood Culture kits due to component expiration prior to the listed kit expiration date. Expired materials could compromise blood culture test accuracy.

    Product
    CENTRAL LINE BLOOD CULTURE DRA, REF DYNDH1562
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0305-2024·2023-11-22

    Defibrillator battery pins may loosen, affecting power

    Physio-Control LIFEPAK 15 defibrillators (serial numbers 48433670 and 48744028) may experience battery pin loosening, potentially causing power issues. Two units were distributed in AZ, CA, NC, NJ, and NY.

    Product
    LIFEPAK 15, REF: 99577-001960, Part Number: V15-7-000026
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0303-2024·2023-11-22

    LIFEPAK 15 Defibrillator Recall: Loose Battery Pins May Cause Power Loss

    Physio-Control is recalling 8 LIFEPAK 15 defibrillators due to loose battery pins that may cause power loss. Affected units were distributed in Arizona, California, North Carolina, New Jersey, and New York.

    Product
    LIFEPAK 15, REF: 99577-001957, Part Number V15-5-000586 and V15-7-000022
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0309-2024·2023-11-22

    Medical Device Reagent Recalled for Unreliable Test Results

    Beckman Coulter's Transferrin reagent lot 2573 does not maintain stability as claimed, causing unreliable patient test results and control failures. The company confirmed the issue affects diagnostic accuracy.

    Product
    AU/DxC AU Chemistry Transferrin REF: OSR6152 Immune complexes formed in solution scatter light in proportion to their size, shape and concentration. Turbidimeters measure the reduction of incident light due to reflection, absorption, or scatter. In the procedure, the measurement
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0297-2024·2023-11-22

    LIFEPAK 15 Defibrillator Recall: Loose Battery Pins May Cause Power Loss

    Physio-Control is recalling LIFEPAK 15 defibrillators due to potential loose battery pins that could result in power loss. Affected devices were distributed in AZ, CA, NC, NJ, and NY.

    Product
    LIFEPAK 15, REF: 99577-000055, Part Number V15-2-000061
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0295-2024·2023-11-22

    IBA Proton Therapy System Patient Positioning Can Move Unexpectedly

    The IBA Proton Therapy System's patient positioning system can perform unexpected motions, risking patient crushing. Five US units and nine international units are affected.

    Product
    IBA Proton Therapy System - PROTEUS 235. PTS-11 versions, PTS-12 versions with Orion PPS version OSS6.0. Configured with Orion Patient Positioning System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0318-2024·2023-11-22

    Express Dry Seal Chest Drains Recalled for Insufficient Setup Instructions

    Atrium Medical Corporation is recalling Express Dry Seal Chest Drains (models 4000-100N and 4050-100N) due to inadequate instructions for proper catheter and patient tube connection setup. No injuries have been reported.

    Product
    Express Dry Seal Chest Drains (Express): 4000-100N DRAIN, EXPRESS, SINGLE; 4050-100N DRAIN, EXPRESS, BRU
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0319-2024·2023-11-22

    CT Scanner Software Bug May Cause Gantry to Move to Wrong Position

    Philips Spectral CT on Rails software version 5.1.0 may fail to move the needle position to the desired location during scans. This could cause the gantry to move unexpectedly and potentially collide with the user or needle.

    Product
    Spectral CT on Rails, Software Version 5.1.0, Model Number 728334
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0301-2024·2023-11-22

    LIFEPAK 15 Defibrillator Recalled for Loose Battery Pins Causing Power Loss

    Physio-Control is recalling LIFEPAK 15 defibrillators due to potential loose battery pins that could cause power failure. Four affected units have been distributed to Arizona, California, North Carolina, New Jersey, and New York.

    Product
    LIFEPAK 15, REF: 99577-001955, Part Number V15-5-000584 and V15-7-000020
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0293-2024·2023-11-22

    Philips Brilliance CT Big Bore May Send Incorrect Coordinates During Radiation Therapy Planning

    Philips Brilliance CT Big Bore units with software V4.8.0.10421 may produce inaccurate image position data when offset reconstruction is used. This could lead to incorrect radiation therapy planning or diagnosis.

    Product
    Brilliance CT Big Bore with software version V4.8.0.10421 Model:728244 CT scanner and simulator designed for radiation oncology and therapy.
    Category
    Medical Device
    Distribution
    Distributed nationwide