The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

1876–1900 of 9961

  • HighCPSC·21158·2021-06-30

    UPPAbaby RumbleSeat Adapters Recalled for Child Fall Hazard

    UPPAbaby is recalling approximately 86,000 RumbleSeat adapters that can detach from strollers, posing a fall hazard to children. The company has received 135 reports of detachments, including injuries such as bumps, scrapes, and two broken noses.

    Product
    UPPAbaby adapters included with Rumbleseats
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·21159·2021-06-30

    Children's Robes Fail Federal Flammability Standards, Pose Burn Risk

    SIORO-branded children's robes sold on Amazon from December 2020 through April 2021 fail to meet federal flammability standards for sleepwear, posing a risk of burn injuries to children.

    Product
    Children's Robes
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·21757·2021-06-24

    La Paloma Girls' Nightgowns Recalled for Flammability Standard Violation

    La Paloma is recalling about 70 girls' nightgowns sold online from November through December 2020 because they fail to meet federal flammability standards for children's sleepwear, posing a burn hazard. No injuries have been reported.

    Product
    Girls' Nightgowns
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·21756·2021-06-24

    Gramr Brushed Gold Tea Kettles Recalled for Burn Hazard

    Gramr is recalling about 92,135 Brushed Gold Tea Kettles because they can expel hot water and excessive steam during use, posing a burn hazard. The company has received 122 reports of the kettles expelling hot water or steam, including 18 reports of minor burn injuries.

    Product
    Brushed Gold Tea Kettles
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·21755·2021-06-24

    Plant Guru Essential Oils Lack Child-Resistant Packaging

    Plant Guru is recalling about 25,600 units of wintergreen, birch, and essential oil blend products because the packaging is not child-resistant despite containing methyl salicylate, which poses a poisoning risk if swallowed by young children.

    Product
    Wintergreen Essential Oil, Birch Essential Oil, Headache Relief Essential Oil Blend, Headache Relief Roll-On Essential Oil Blend, and Deep Muscle Essential Oil Blend
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·21E056000·2021-06-23

    R.C. Willett NorthStar Truck Campers Recalled for Gas Leak Risk

    R.C. Willett is recalling NorthStar 8.5 Arrow U truck campers with specific Dometic stoves because an over-tightened bolt may damage the seal, causing a gas leak and fire risk.

    Product
    EQUIPMENT:APPLIANCE:OVEN/STOVE/COOKTOP recall
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·21151·2021-06-16

    Cove Appliance 24-inch Built-in Dishwashers Recalled for Fire Hazard

    Cove Appliance is recalling about 42,000 built-in dishwashers because the heating element can fail to shut off and overheat, creating a fire hazard. The company has received five reports of burning smells, flames, and smoking inside the dishwashers, though no injuries have been reported.

    Product
    Cove Appliance 24-inch built-in dishwashers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·21754·2021-06-10

    Children's Barhee Fishing Hero Toy Games Recalled for Excessive Lead Content

    Blue Star Trading is recalling about 300 Barhee Fishing Hero toy games sold on Amazon.com because metal rollers on the flying dinosaur figures contain lead levels exceeding the federal ban. Lead is toxic to young children if ingested.

    Product
    Children's Barhee Fishing Hero Toy Games
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereCPSC·21150·2021-06-09

    Klein Tools Non-Contact Voltage Tester Recalled for Shock Hazard

    Klein Tools non-contact voltage testers (model NCVT-1) are recalled because the on/off button can fail to disengage, causing the tester to malfunction and potentially fail to detect live voltage. One shock injury has been reported.

    Product
    Klein Tools Non-Contact Voltage Tester Model NCVT-1
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·21149·2021-06-09

    CamelBak Water Bottle Caps Recalled for Choking Hazard

    CamelBak is recalling certain caps sold with Podium and Peak Fitness water bottles because a small silicone valve can come loose and detach, posing a choking hazard. No injuries have been reported.

    Product
    CamelBak Podium and Peak Fitness water bottles
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • ModerateFDA (Food)·F-0649-2021·2021-06-09

    Genpak Bake n Show Muffin Trays Recalled for Foreign Objects

    Genpak is recalling Bake n Show Muffin Trays in three sizes due to the discovery of foreign objects in product packaging. The recall affects units distributed across multiple US states and Canada.

    Product
    Bake n Show¿ Muffin Tray 4 Cavity Large, Bake n Show¿ Muffin Tray 4 Cavity Large Shallow & Bake n Show¿ Muffin Tray 6 Cavity
    Category
    Consumer Product
    Distribution
    24 states
  • ModerateFDA (Food)·F-0651-2021·2021-06-09

    Genpak Bake n Show Cake Trays Recalled for Foreign Objects

    Genpak is recalling Bake n Show Round and Square Cake Trays due to the presence of foreign objects found in product packaging. The trays were distributed across multiple U.S. states and Canada.

    Product
    Bake n Show¿ Cake Tray Round & Bake n Show¿ Cake Tray Square
    Category
    Consumer Product
    Distribution
    24 states
  • ModerateFDA (Food)·F-0648-2021·2021-06-09

    Genpak Bake n Show Angel Food Trays Recalled for Foreign Objects

    Genpak is recalling Bake n Show Angel Food Trays (8-inch and 8-inch shallow models) because foreign objects were found in the product packaging. Consumers should stop using affected trays.

    Product
    Bake n Show¿ Angel Food Tray 8 Inch & 8 inch shallow
    Category
    Consumer Product
    Distribution
    24 states
  • CriticalCPSC·21147·2021-06-03

    Fisher-Price Recalls Rock 'n Glide Soothers After Four Infant Deaths

    Fisher-Price is recalling 4-in-1 Rock 'n Glide Soothers and 2-in-1 Soothe 'n Play Gliders due to reports of four infant deaths from suffocation.

    Product
    Fisher-Price 4-in-1 Rock 'n Glide Soothers and 2-in-1 Soothe 'n Play Gliders
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·21752·2021-06-03

    Kalorik Recalls Electric Steakhouse Grills Due to Electric Shock Hazard

    Kalorik is recalling Pro 1500F Electric Steakhouse Grills because incorrectly electroplated knobs can cause electric shocks after the grill preheats.

    Product
    Kalorik Pro 1500F Electric Steakhouse Grills
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·21E049000·2021-06-02

    Adventurer Truck Campers Recalled for Potential Gas Leak from Dometic Stoves

    Adventurer LP is recalling specific truck campers equipped with Dometic stoves because a saddle valve bolt may be overtightened, causing a gas leak that increases fire risk.

    Product
    EQUIPMENT:APPLIANCE:OVEN/STOVE/COOKTOP recall
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·21750·2021-05-27

    Williams Advanced Materials Recalls Three Chemicals for Packaging and Labeling Violations

    Williams Advanced Materials & Chemicals is recalling sodium hydroxide, heptane, and naphtha because the packaging is not child-resistant and labels violate federal requirements.

    Product
    Williams Advanced Materials & Chemicals Recalls Three Chemical Products Due to Failure to Meet Child-Resistant Packaging Requirement and Violation of FHSA Labeling Requirement (Recall Alert)
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·21751·2021-05-27

    Umbrosa Pool and Patio Umbrellas Recalled Due to Arm Breakage Hazard

    Umbrosa is recalling about 250 pool and patio umbrellas because the arm can break at the elbow while in use, posing an injury hazard.

    Product
    Umbrosa umbrellas equipped with the Umbrosa Evolution Arm/Holder
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereCPSC·21138·2021-05-26

    HSN Recalls 5.4 Million Handheld Clothing Steamers Due to Burn Hazard

    HSN is recalling 5.4 million Joy/JM-branded My Little Steamer handheld clothing steamers because they can expel hot water, posing a serious burn hazard.

    Product
    Joy/JM-branded My Little Steamer® and My Little Steamer® Go Mini
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·21139·2021-05-26

    Ergobaby Recalls METROUS Strollers Due to Choking Hazard

    Ergobaby is recalling METROUS strollers because a harness buckle button can break and detach, posing a choking hazard to young children.

    Product
    METROUS1, METROUS2 and METROUS4 Compact City Strollers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·21141·2021-05-26

    Target Recalls Room Essentials Shower Stools Due to Fall Hazard

    Target is recalling Room Essentials Shower Stools because they can become unstable or slippery, posing a fall hazard. About 58,500 units were sold.

    Product
    Room Essentials Shower Stools
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·21V371000·2021-05-20

    2021 Forest River Columbus Dining Chair Legs May Detach During Use

    The Allure Swivel Dining chair legs in 2021 Forest River Columbus trailers may detach, creating an injury risk if occupied. Dealers will install reinforcing hardware free of charge.

    Product
    FOREST RIVER — FOREST RIVER COLUMBUS
    Category
    Consumer Product
    Distribution
    Distributed nationwide