The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

2951–2975 of 14957

  • HighNHTSA·23V661000·2023-09-29

    Kenworth and Peterbilt Trucks Recalled for Trailer Brake Timing Delay

    PACCAR is recalling certain 2020–2024 Kenworth and Peterbilt commercial trucks. Delayed trailer brake release can create trailer instability and increase crash risk.

    Product
    PETERBILT — PETERBILT, KENWORTH 536, T380, 548, T280
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V658000·2023-09-29

    2024 Forest River Wildwood fifth wheels missing emergency exit

    Forest River is recalling certain 2024 Wildwood and Salem fifth wheels that may be missing a secondary emergency exit window, which could delay occupant egress in an emergency.

    Product
    FOREST RIVER — FOREST RIVER SALEM, WILDWOOD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V660000·2023-09-29

    Forest River Recalls 2024 Coachmen and Shasta Trailers for Fire Risk

    Forest River is recalling 2024 Coachmen and Shasta fifth wheel trailers because an incorrect fuse in the power distribution center may increase the risk of a fire.

    Product
    COACHMEN — COACHMEN, SHASTA BROOKSTONE, CHAPARRAL, PHOENIX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V663000·2023-09-29

    Winnebago Revel motorhomes electrical cable fire risk recall

    Winnebago is recalling certain 2020–2024 Revel motorhomes because cables near the lithium batteries may contact battery hold-down brackets, damaging the cables and causing a short circuit that increases fire risk.

    Product
    WINNEBAGO — WINNEBAGO REVEL
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V659000·2023-09-29

    Coachmen Prism and Concord Recalled for Incorrect Federal Placard Information

    Forest River is recalling 2021-2024 Coachmen Prism and 2023-2024 Concord vehicles because the Federal Placard may display incorrect seat belt counts, potentially leading to vehicle overloading.

    Product
    COACHMEN — COACHMEN PRISM, CONCORD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V655000·2023-09-28

    Diamond C Trailers Recall 2023-2024 Models Due to Winch Failure

    Diamond C is recalling 2023-2024 FMAX, SDX, and PX trailers because the spare tire winch may loosen or fail, increasing crash risk.

    Product
    DIAMOND C TRAILERS — DIAMOND C TRAILERS FMAX, PX, SDX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V656000·2023-09-28

    Autocar Recalls Xpeditor and Legend Vehicles for Steering Defect

    Autocar is recalling 2022-2023 Xpeditor and 2023 Legend vehicles because a steering column bolt may not be secured, risking sudden loss of steering.

    Product
    AUTOCAR — AUTOCAR XPEDITOR, LEGEND
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V654000·2023-09-28

    2024 RAM 2500 Rearview Camera Display Software Malfunction Recall

    Chrysler recalls 2024 RAM 2500 vehicles due to radio software that may prevent the rearview camera from displaying. Loss of rearview visibility increases crash risk.

    Product
    RAM — RAM 3500, 2500, 1500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V657000·2023-09-28

    2023 Nissan Ariya Inverter Software May Cause Loss of Drive Power

    Nissan is recalling certain 2023 Ariya vehicles due to a potential inverter software defect that may cause an unexpected loss of drive power. The loss of drive power increases the risk of a crash.

    Product
    NISSAN — NISSAN ARIYA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V653000·2023-09-27

    Peterbilt 567 and 579 Trucks: Fuel Tank Puncture Risk from Loose U-bolts

    PACCAR is recalling 2021-2024 Peterbilt 567 and 579 trucks. U-bolts securing the air tank can contact and wear through the fuel tank over time. A punctured tank can leak fuel, increasing the risk of fire.

    Product
    PETERBILT — PETERBILT 579, 567
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V652000·2023-09-25

    Kia Recalls Multiple Models Due to Electrical Short Fire Risk

    Kia is recalling 1.7 million vehicles because an electrical short in the brake control unit may cause an engine compartment fire.

    Product
    KIA — KIA SORENTO, RIO, OPTIMA HYBRID, SOUL
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V651000·2023-09-22

    Hyundai Recalls Multiple Models Due to ABS Module Fire Risk

    Hyundai is recalling over 1.6 million vehicles because a leaking ABS module may cause an engine compartment fire. Owners should park outside until the repair is complete.

    Product
    HYUNDAI — HYUNDAI ELANTRA, AZERA, SANTA FE, GENESIS COUPE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V649000·2023-09-22

    2023 Kia Forte Right Front Control Arm Defect Recall

    Kia is recalling 2023 Forte vehicles due to improper welds on the right front lower control arm, which may fail and cause loss of steering control. Affected owners should not drive the vehicle until repaired.

    Product
    KIA — KIA FORTE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V648000·2023-09-22

    2024 East to West RV Recall: Detachable Rear Ladder Poses Injury Risk

    Forest River is recalling certain 2024 East to West Blackthorn and Tandara fifth wheels. The rear ladder may detach due to improper anchoring, creating a potential injury risk.

    Product
    EAST TO WEST — EAST TO WEST TANDARA, BLACKTHORN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V650000·2023-09-22

    2024 Hyundai Kona Seat Belt Retractor Malfunction Recall

    Hyundai is recalling certain 2024 Kona vehicles because the rear seat belt retractors may not function properly. A defective seat belt could fail to restrain occupants in a crash, increasing injury risk.

    Product
    HYUNDAI — HYUNDAI KONA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V647000·2023-09-21

    2023 Subaru Driveshaft Center Support Bolts May Loosen

    Subaru is recalling certain 2023 Ascent, Legacy, Impreza, and Outback vehicles because center support bolts for the driveshaft may loosen, potentially causing the driveshaft to disconnect and increasing crash risk. Dealers will clean and replace the bolts at no charge.

    Product
    SUBARU — SUBARU OUTBACK, ASCENT, LEGACY, IMPREZA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V642000·2023-09-20

    2023 Chevrolet Tahoe and Related Models Suspension Bolt Recall

    General Motors is recalling certain 2023 Tahoe, Suburban, Escalade, Escalade ESV, Yukon, and Yukon XL vehicles due to improperly heat-treated rear suspension bolts that may break, risking wheel misalignment and crash.

    Product
    CADILLAC — CADILLAC, CHEVROLET, GMC ESCALADE ESV, SUBURBAN, TAHOE, YUKON
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V644000·2023-09-20

    BMW Recalls 2023 740i, 760i, and i7 Models for Wiper Failure

    BMW is recalling 2023 740i, 760i, and i7 vehicles because windshield wipers may fail in certain weather, reducing visibility and increasing crash risk.

    Product
    BMW — BMW 760I, I7, 740I
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V646000·2023-09-20

    Wabash National Dry Van Trailers Recalled for Rear Impact Guard Defect

    Wabash National is recalling certain 2009-2024 dry van trailers because the rear impact guard is positioned too far forward, potentially reducing crash protection. Dealers will add an extension to the guard free of charge.

    Product
    WABASH NATIONAL — WABASH NATIONAL VAN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V674000·2023-09-20

    GM Recalls 2014 Buick Verano and Chevrolet Cruze for Air Bag Defect

    General Motors is recalling 2014 Buick Verano and Chevrolet Cruze vehicles because side roof-rail air bag inflators may rupture, potentially causing injury from metal fragments.

    Product
    CHEVROLET — CHEVROLET, BUICK CRUZE, VERANO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V643000·2023-09-20

    Tiffin motorhomes recalled for cooktop electrical shock hazard

    Tiffin is recalling certain 2016-2024 Allegro Bus and 2017-2024 Zephyr motorhomes because the 240-volt cooktop may not be grounded, creating an electrical shock hazard. Tiffin will install a ground for the junction box at no charge.

    Product
    TIFFIN — TIFFIN ALLEGRO BUS, ZEPHYR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23E068000·2023-09-18

    Hyundam Fuel Pump Recall for Potential Loss of Drive Power

    Hyundam Industrial is recalling fuel pumps where the impeller may deform, causing pump failure and loss of drive power, which increases the risk of a crash.

    Product
    FUEL SYSTEM, GASOLINE:DELIVERY:FUEL PUMP recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23E069000·2023-09-18

    Chrysler Recalls Mopar Gear Position Sensors and Transmission Assemblies

    Chrysler is recalling specific Mopar Gear Position Sensors and Transmission Assemblies because they may cause rearview camera and reverse light failures, increasing crash risk.

    Product
    POWER TRAIN:MANUAL TRANSMISSION recall
    Category
    Vehicle
    Distribution
    Distributed nationwide