The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

27801–27825 of 40357

  • SevereFDA (Devices)·Z-0924-2017·2017-02-01

    Philips Allura Xper FD20 C-arm Recall Due to Loose Screws

    Philips is recalling two Allura Xper FD20 C-arm systems because production errors left screws loose, posing a risk of uncontrolled rotation.

    Product
    Allura Xper FD20 R8.2 722028 is intended for: Cardiovascular and vascular X-ray imaging applications, including diagnostic, interventional procedures (such as PTCA, stent placement and atherectomies), pacemaker implantations and Electrophysiology(EP).
    Category
    Medical Device
    Distribution
    1 state
  • SevereFDA (Devices)·Z-1099-2017·2017-02-01

    Roche Recalls Accu-Chek Connect App Due to Insulin Dosing Errors

    Roche Diabetes Care is recalling the Accu-Chek Connect app because software defects may cause incorrect insulin bolus recommendations, potentially leading to hypoglycemia.

    Product
    Accu-Chek Connect Diabetes Management App
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1066-2017·2017-02-01

    Villa Radiology Systems Recalls Apollo EZ X-Ray Systems Due to Injury Risk

    Villa Radiology Systems LLC is recalling 66 Apollo EZ multi-function x-ray systems because a chain of faults caused an injury to a user.

    Product
    Apollo EZ: Model: 9784152036 Multi-function x-ray systems capable of routine radiograph and general fluoroscopy procedures.
    Category
    Medical Device
    Distribution
    26 states
  • SevereFDA (Devices)·Z-0922-2017·2017-02-01

    Philips Allura Xper FD20 C-arm Recall for Loose Screws

    Philips is recalling one Allura Xper FD20 unit because production errors left screws loose, which could cause the C-arm to rotate uncontrolled.

    Product
    Allura Xper FD20 722012 is intended for: Cardiovascular and vascular X-ray imaging applications, including diagnostic, interventional procedures (such as PTCA, stent placement and atherectomies), pacemaker implantations and Electro Physiology(EP).
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-1097-2017·2017-02-01

    Softbank II Transfusion Software Recalled for Potential Incorrect Results

    Soft Computer Consultants is recalling Softbank II software due to a software error that may produce incorrect results in transfusion services.

    Product
    SCC Soft Computer Softbank II software Product Usage: Supports single and multi-site transfusion services in healthcare facilities. Used by healthcare personal to document, query, and view the integrated information regarding patients and products. Quality control testing…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1077-2017·2017-02-01

    Roche Recalls 30 Cobas b 123 POC Systems for Quality Control Issue

    Roche Diagnostics is recalling 30 cobas b 123 POC systems because a software issue may prevent automatic quality control from running, potentially leading to undetected incorrect test results.

    Product
    Cobas b 123 POC system The cobas b 123 POC system is a fully automated POC system for whole blood in vitro measurement of pH, blood gases (B3G), electrolytes Nat, K+, iCaWt (ISE), hematocrit (THct), metabolites (Glu, Lac), total hemoglobin (tHb), hemoglobin derivatives (O2Hb…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1076-2017·2017-02-01

    INOmax DSIR Plus Delivery System Recalled for Inaccurate Valve Calibration

    INO Therapeutics is recalling 45 INOmax DSIR Plus delivery systems because an out-of-tolerance manometer may cause inaccurate valve calibration.

    Product
    Mallinckrodt Pharmaceuticals INOmax DSIR Plus delivery system. Model 10007. Delivers INOMAX (nitric oxide for inhalation). The INOmax DSIR uses a dual-channel design to ensure the safe delivery of INOMAX. The first channel has the delivery CPU, the flow controller and…
    Category
    Medical Device
    Distribution
    18 states
  • HighFDA (Devices)·Z-1095-2017·2017-02-01

    Baxter Recalls Phoenix Dialysis Machine Preventive Maintenance Kits

    Baxter Healthcare is recalling Phoenix Dialysis Machine Preventive Maintenance Kits due to incorrect silicone connectors that may cause fluid leaks.

    Product
    Maintenance Kit PH2, Cod. 6997274 The Phoenix Hemodialysis delivery system is intended to be used to provide high flux and low flux hemodialysis, hemofiltration and ultrafiltration on patients weighing 15 Kilograms or more. The Phoenix system is to be used with either high or…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1074-2017·2017-02-01

    Medline Recalls Unna-Z Compression Wraps Due to Mold Contamination

    Medline Industries is recalling Unna-Z compression wraps due to contamination with common mold species. The recall affects units distributed in the US and several international countries.

    Product
    Unna-Z, Unna Boot with Zinc and Calamine, Compression Wrap, 1 Per Box, 3-4in x 10yds
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1081-2017·2017-02-01

    Atrium Medical Recalls Pediatric Ocean Drains Due to Non-Sterile Packaging

    Atrium Medical is recalling Pediatric Chamber Ocean Drains because the outer packaging is not sterile. The recall covers units with expiration dates prior to October 2019.

    Product
    Atrium Medical Pediatric Chamber Ocean Drains as follows: 2012-320 Ocean Infant/Pediatric drain, with in-line connector and suction control stopcock, ¿ in. Tubing, Sims and Pedi connector in bag on back of drain Product Usage: To evacuate air and/or fluid from the chest…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1098-2017·2017-02-01

    Softbank Transfusion Software Recalled for Potential Incorrect Results

    Soft Computer Consultants is recalling Softbank decision support software due to a software error that may produce incorrect results.

    Product
    Softbank software Product Usage: Decision support software for transfusion service. It keeps track of inventory from outside sources, multi-site inventory control, records of testing of units, and allows for record keeping for transfusion preparation.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1085-2017·2017-02-01

    Atrium Medical Oasis Dual Chamber Drain Recall Due to Sterility Issue

    Atrium Medical is recalling Oasis dual chamber drains because the outer packaging is not sterile. The recall affects units with expiration dates prior to October 2019.

    Product
    Atrium Medical 3620-100: Oasis dual chamber drain with in-line connectors (2 Patient Tubes) Product Usage: To evacuate air and/or fluid from the chest cavity or mediastinum.  To help re-establish lung expansion and restore breathing dynamics.  To facilitate postoperative…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1061-2017·2017-02-01

    Philips Recalls Velara Generators Due to Potential System Lockup

    Philips is recalling 59 Velara Generators used with Allura Xper Systems because the devices may lock up. The recall is voluntary and covers units in the US and internationally.

    Product
    Velara Generator with an old Firmware version used with Philips Allura Xper Systems (Allura 15 & 12 (monoplane), Allura FD10C, Allura FD10F, Allura FD 10 F/C, Allura FD20, Allura XPER FD10/10, Allura XPER FD20 Biplane)
    Category
    Medical Device
    Distribution
    16 states
  • HighFDA (Devices)·Z-1106-2017·2017-02-01

    Philips Cisco 3850 Switch Recall Due to Monitoring Loss Risk

    Philips is recalling Cisco 3850 switches used with IntelliVue systems because they may experience a loss of centralized monitoring.

    Product
    Philips Cisco 3850 layer 3 switch, 865339 model WS-C3850-12S-E in use with IntelliVue Information Center iX or Classic Information Center
    Category
    Medical Device
    Distribution
    19 states
  • HighFDA (Devices)·Z-1083-2017·2017-02-01

    Atrium Medical Oasis Single Drain Recalled for Non-Sterile Packaging

    Atrium Medical is recalling Oasis Single Drains because the outer packaging is not sterile, posing a risk of infection.

    Product
    Atrium Medical Oasis Single Drain as follows: 3600-100 Oasis single drain with in-line connector 3600-150 Oasis single drain with in-line connector and Pre-connected 2550 ATS Bag Product Usage: To evacuate air and/or fluid from the chest cavity or mediastinum.  To help…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1062-2017·2017-02-01

    Philips Velara Generator Recall for System Lockup Risk

    Philips is recalling 59 Velara Generators with old firmware used with the Integris BH5000 because the system may lock up.

    Product
    Velara Generator with an old Firmware version used with the Philips Integris BH5000
    Category
    Medical Device
    Distribution
    16 states
  • HighFDA (Devices)·Z-1091-2017·2017-02-01

    Merge Hemo software recall due to potential connection issues

    Merge Healthcare is recalling Merge Hemo software versions 6.10 through 9.40.3 because the Hemo Monitor may fail to communicate with the Client PC during power-up.

    Product
    Merge Hemo software. Merge Hemo monitors, measures, and records physiologic data from a human patient undergoing a cardiac catheterization procedure
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1096-2017·2017-02-01

    Hitachi Oasis MRI C-Spine Coil Recalled Due to Overheating Balun

    Hitachi Medical Systems America Inc is recalling 180 Hitachi Oasis MRI System C-Spine Coils because the coil balun was found to be hot to the touch after an exam.

    Product
    Hitachi Oasis MRI System - C-Spine Coil
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1094-2017·2017-02-01

    Baxter Recalls Phoenix Dialysis Machine Preventive Maintenance Kits

    Baxter Healthcare is recalling Phoenix Dialysis Machine Preventive Maintenance Kits due to incorrect silicone connectors that may cause fluid leaks during dialysis.

    Product
    Maintenance Kit PH1, Cod. 6997266 The Phoenix Hemodialysis delivery system is intended to be used to provide high flux and low flux hemodialysis, hemofiltration and ultrafiltration on patients weighing 15 Kilograms or more. The Phoenix system is to be used with either high or…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1090-2017·2017-02-01

    Roche Recalls Five cobas p 612 Pre-analytical Systems in Texas and Washington

    Roche Diagnostics is voluntarily recalling five cobas p 612 pre-analytical systems in Texas and Washington. The recall was initiated on December 27, 2016, and classified as Class II.

    Product
    cobas p 612 pre-analytical system; Pre-analytical sample handling that includes de-capping, Aliquotting and sorting of samples for analysis.
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1092-2017·2017-02-01

    Roche Tina-Quant CRP Latex Test System Recalled for Low Results

    Roche is recalling Tina-Quant CRP Latex High Sensitive test kits due to potential under-recovery of results, which may lead to incorrect cardiovascular risk assessments.

    Product
    Tina-Quant (Latex) HS Test System (C-Reactive Protein (Latex) High Sensitive) The Tina-Quant CRP (Latex) High Sensitive Immunoturbidimetric assay is for the in-vitro quantitative determination of C-reactive protein (CRP) in human serum and plasma on Roche automated clinical…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1069-2017·2017-02-01

    Binding Site IgG4 Reagent Kits Recalled for Inaccurate Results

    The Binding Site Group is recalling Human IgG4 Subclass Liquid Reagent Kits because they may yield falsely low results for samples with extremely high IgG4 levels.

    Product
    Human lgG4 Subclass Liquid Reagent Kits For use on the Roche Cobas"6000 This kit is intended for qualifying human IgG subclasses 1,2,3 and 4 immunoglobulins in serum on the Beckman Coulter AU series. Meaurement of these immunoglobulins ais in the diagnosis of abnormal…
    Category
    Medical Device
    Distribution
    6 states
  • ModerateFDA (Devices)·Z-1080-2017·2017-02-01

    Atrium Medical Recalls Dual Chamber Ocean Drains Due to Sterility Issues

    Atrium Medical is recalling Dual Chamber Ocean Drains because the outer packaging is not sterile. The recall affects units with expiration dates prior to October 2019.

    Product
    Atrium Medical Dual Chamber Ocean Drains as follows: 2020-000 Ocean dual chamber, in-line connectors and suction control stopcock (2 Patient Tubes) 2020-100 Ocean dual chamber with in-line connectors and no suction control stopcock (2 Patient Tubes) 2020-300 Ocean dual…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1070-2017·2017-02-01

    Binding Site IgG4 Reagent Kits Recalled for Inaccurate Results

    The Binding Site Group is recalling Human IgG4 Subclass Liquid Reagent Kits because they may yield spuriously low results for samples with extremely high IgG4 levels.

    Product
    Human lgG4 Subclass Liquid Reagent Kits Human lgG1& lgG2 Antisera, lgG3 & 4 Latex reagent and lgG Antisera for use on Hitachi 911/912/917 and Hitachi Modular P Product Code LK009.H/LK001.H This kit is intended for qualifying human IgG subclasses 1,2,3 and 4 immunoglobulins…
    Category
    Medical Device
    Distribution
    6 states
  • ModerateFDA (Devices)·Z-1079-2017·2017-02-01

    Atrium Medical Ocean Drains Recalled Due to Non-Sterile Outer Packaging

    Atrium Medical is recalling Ocean Drains because the outer packaging is not sterile. The recall covers units with expiration dates prior to October 2019.

    Product
    Atrium Medical Ocean Drains as follows: 2002-000 Ocean single drain, with in-line connectors and suction control stopcock 2002-040 Ocean single drain, in-line connector and suction control stopcock, Pedi connector in bag on back of the drain 2002-050 Ocean single drain…
    Category
    Medical Device
    Distribution
    Distributed nationwide