The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

20526–20550 of 40124

  • HighFDA (Devices)·Z-1594-2019·2019-06-05

    Maquet Getinge ECC Tubing Sets Recalled for Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific ECC tubing sets because a design feature may prevent sterilization gas from reaching all fluid paths, potentially compromising sterility.

    Product
    Maquet Getinge-BEQ-TOP 8208#3/8 inch ECC Pack Material: 701068798
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1514-2019·2019-06-05

    Maquet Getinge Custom Tubing Sets Recalled for Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific custom tubing sets for extracorporeal circulation because a design feature may prevent proper sterilization, potentially compromising sterility.

    Product
    Maquet Getinge-BEQ-TOP 15705 Material: 701051122
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1517-2019·2019-06-05

    Maquet Getinge-BEQ-TOP 5502 ECC Pack Recall for Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific batches of ECC packs because a design feature may prevent proper sterilization, potentially compromising sterility.

    Product
    Maquet Getinge-BEQ-TOP 5502 ECC Pack Material: 701051791
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1672-2019·2019-06-05

    Maquet Cardiovascular Recalls Custom Tubing Sets for Extracorporeal Circulation

    Maquet Cardiovascular is recalling custom tubing sets for extracorporeal circulation because a design flaw may prevent sterilization gas from reaching all parts of the device.

    Product
    Maquet Getinge-BEQ-TOP 35503 SGD Pack Material:701068797R01
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1513-2019·2019-06-05

    Maquet Getinge-BO-TOP 26300 Custom Tubing Sets Recalled for Sterility Assurance Issues

    Maquet Cardiovascular is recalling specific custom tubing sets for extracorporeal circulation because a design configuration may prevent proper sterilization, potentially compromising sterility.

    Product
    Maquet Getinge-BO-TOP 26300 CUSTOM PACK Material: 701050975
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1493-2019·2019-06-05

    Abbott TactiSys Quartz Equipment Recalled for Log Storage Defect

    Abbott is recalling 317 TactiSys Quartz Equipment units because a software defect prevents new log data from being stored, which may cause intermittent contact force data display.

    Product
    TactiSys Quartz Equipment (with software version 1.7) Model: PN-004 400 Part Numbers: 600043767 (China), 100154367 (Global), 100154368 (SWAP)
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1523-2019·2019-06-05

    Maquet Pediatric ECC Tubing Sets Recalled for Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific pediatric extracorporeal circulation tubing sets because a design feature may prevent proper sterilization, potentially compromising sterility.

    Product
    Maquet Getinge-BEQ-TOP 31000 PEDIATRIC ECC Material:701052843
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1576-2019·2019-06-05

    Maquet Getinge Custom Tubing Sets Recalled for Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific custom tubing sets for extracorporeal circulation because a design feature may prevent proper sterilization, potentially compromising sterility.

    Product
    Maquet Getinge-BEQ-T 16405 LIVER TX INFUSION Material:701066097
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1677-2019·2019-06-05

    Maquet Getinge Rotaflow Pack Recall Due to Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific Rotaflow Packs because a design feature may prevent proper sterilization, potentially compromising sterility.

    Product
    Maquet Getinge- BEQ-T 53500 Evanston Rotaflow Pack Material:709000215R01
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1625-2019·2019-06-05

    Maquet Getinge Rotaflow Support Pack Recalled Due to Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific Rotaflow Support Packs because a design feature may prevent proper sterilization, potentially compromising sterility.

    Product
    Maquet Getinge-BEQ-T 48003 Rotaflow ONLY Support Pack Material:709000490
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1530-2019·2019-06-05

    Maquet Getinge Custom Tubing Sets Recalled for Sterility Assurance Concerns

    Maquet Cardiovascular is recalling custom tubing sets for extracorporeal circulation because a design feature may prevent sterilization gas from reaching all parts of the fluid path.

    Product
    Maquet Getinge-BEQ-TOP 25001 MONTEFIORE Material: 701053906
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1641-2019·2019-06-05

    Maquet Neonate ECC Tubing Sets Recalled for Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific neonate extracorporeal circulation tubing sets because a design feature may prevent proper sterilization, potentially compromising sterility.

    Product
    Maquet Getinge-BEQ-TOP 28601 NEONATE ECC QPiD Material: 701051935R01
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1502-2019·2019-06-05

    Maquet Getinge ECC Tubing Sets Recalled Due to Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific batches of custom tubing sets for extracorporeal circulation because a design feature may prevent proper sterilization.

    Product
    Maquet Getinge-BEQ-TOP 17207 3/8 ECC PACK Material: 701049346
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1621-2019·2019-06-05

    Maquet Getinge Tubing Sets Recalled Due to Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific tubing sets for extracorporeal circulation because a design feature may prevent proper sterilization of the stopcock ports.

    Product
    Maquet Getinge-BEQ-T 25502 1/4 Better Bladder Material: 709000434
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1548-2019·2019-06-05

    Maquet Getinge-BEQ-TOP 26402 ECC Pack Recall Due to Sterility Concerns

    Maquet Cardiovascular is recalling specific batches of ECC Packs because a design feature may prevent proper sterilization, potentially compromising sterility.

    Product
    Maquet Getinge-BEQ-TOP 26402 ECC PACK Material: 701062310
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1619-2019·2019-06-05

    Maquet Cardiovascular Recalls Custom Tubing Sets for Extracorporeal Circulation

    Maquet Cardiovascular is recalling custom tubing sets for extracorporeal circulation because a design flaw may prevent sterilization gas from reaching all parts of the device.

    Product
    Maquet Getinge-BEQ-T 9409 Lurie Chlds Large 3/8 Material: 709000428
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1649-2019·2019-06-05

    Maquet Getinge Custom Tubing Sets Recalled for Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific custom tubing sets for extracorporeal circulation because a design feature may prevent proper sterilization gas flow.

    Product
    Maquet Getinge- BEQ-TOP 32100 Adult Custom Pack Material:701054438R01
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1691-2019·2019-06-05

    NeuroLogica Recalls Samsung GM85 Mobile Digital X-ray Imaging Systems

    NeuroLogica is recalling 288 Samsung GM85 Mobile Digital X-ray Imaging Systems due to a potential safety latch issue that could cause the arm to fall.

    Product
    Samsung GM85 Mobile Digital X-ray Imaging System Product Usage: The GM85 Digital X-ray imaging System is intended for use in generating radiographic images of human anatomy by a qualified/trained doctor or technician. This device is not intended for mammographic…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1679-2019·2019-06-05

    Maquet Getinge Custom Tubing Sets Recalled for Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific custom tubing sets for extracorporeal circulation because a design feature may prevent proper sterilization.

    Product
    Maquet Getinge- BEQ-T 9411 Lurie Children's 1/4 ADAPT Material:709000485R01
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1665-2019·2019-06-05

    Maquet Getinge Children's ECC Tubing Sets Recalled for Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific Children's Large ECC Packs because a design feature may prevent proper sterilization, potentially compromising sterility.

    Product
    Maquet Getinge-BEQ-TOP 49101 Childrens Large ECC Pack Material: 701067069R01
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1533-2019·2019-06-05

    Maquet Getinge Custom Tubing Sets Recalled for Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific custom tubing sets for extracorporeal circulation because a design feature may prevent proper sterilization, potentially compromising sterility.

    Product
    Maquet Getinge-BEQ-TOP 32100 ADULT CUSTOM PAC Material:701054438
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1552-2019·2019-06-05

    Maquet Custom Tubing Sets Recalled for Sterility Assurance Concerns

    Maquet Cardiovascular is recalling custom tubing sets for extracorporeal circulation because a design feature may prevent proper sterilization, potentially compromising sterility.

    Product
    Maquet Getinge-BEQ-TOP 30901 CUSTOM CPB PACK Material:701063071
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1645-2019·2019-06-05

    Maquet Custom Tubing Sets Recalled for Sterility Assurance Concerns

    Maquet Cardiovascular is recalling custom tubing sets for extracorporeal circulation because a design flaw may prevent proper sterilization, potentially compromising sterility.

    Product
    Maquet Getinge-BEQ-TOP 250011/4 1/4 Less than 20 kg up Material: 701053906R01
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1603-2019·2019-06-05

    Maquet Getinge ECC Tubing Sets Recalled for Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific batches of custom tubing sets for extracorporeal circulation because the design may prevent proper sterilization gas flow.

    Product
    Maquet Getinge-BEQ-T 51502 Ochsner ECC Ancillary Pack Material:709000115
    Category
    Medical Device
    Distribution
    Distributed nationwide