Zimmer Biomet Recalls Orthopedic Surgical Instruments Due to Fracture Risk
Zimmer Biomet is recalling 171 orthopedic surgical instruments because raw material anomalies may increase the risk of instrument fracture during use.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: The recall involves a risk-of-harm product (instrument fracture) where injury has not yet been reported, which aligns with the 'High' severity criteria in the rubric.
Plain-English summary
Zimmer Biomet, Inc. is recalling 171 units of the Zimmer Periarticular Locking Plate System Locking Screw Tap Standard Quick-Connect, 2.7 mm Diameter (Item Number/EDI 00236015327). These nonsterile orthopedic surgical instruments were distributed nationwide in the United States and internationally to Australia, Brazil, Canada, China, El Salvador, Germany, Guatemala, India, Japan, Panama, Malaysia, Mexico, Netherlands, South Korea, Singapore, Taiwan, and Trinidad.
The recall was initiated because various trauma and extremity instruments, including drill bits and screw taps, were manufactured from raw material with an anomaly. This anomaly may be on or below the surface and can increase the risk of instrument fracture. The affected lot numbers are 63574373, 63622721, 63398756, 63415316, 63444654, 63462301, 63474169, 63485122, 63485126, 63496894, 63505359, 63530405, and 63530406.
Healthcare providers and facilities should stop using these instruments and contact Zimmer Biomet for further instructions. The source text does not report any specific injuries or illnesses associated with this recall.
The recalled product
- Product
- Zimmer Periarticular Locking Plate System Locking Screw Tap Standard Quick-Connect, 2.7 mm Diameter, Item Number/EDI 00236015327, Nonsterile. orthopedic surgical instrument.
- Manufacturer
- Zimmer Biomet, Inc.
- Hazard
- Affected units
- 171
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (12)
- Lot Numbers: 63574373
- 63622721
- 63398756
- 63415316
- 63444654
- 63462301
- 63474169
- 63485122
- 63485126
- 63496894
- 63505359
- 63530405 & 63530406
Distribution
Distributed nationwide across the United States.
Part of a larger recall action
This product is one of 60 recalled by Zimmer Biomet, Inc. under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.
See all 60 products in this recall →Related recalls
Same manufacturer · Zimmer Biomet, Inc.
See all →- HighZimmer Biomet Recalls Spinal Rod Cutters Due to Fracture Risk
FDA (Devices) · 2020-12-30
- ModerateZimmer Biomet Recalls Polaris Spinal System Screws for Labeling Update
FDA (Devices) · 2020-12-23
- HighZimmer Biomet Recalls Hip Prosthesis Cups Due to Sterilant Biocompatibility Concerns
FDA (Devices) · 2020-11-11
- HighZimmer Biomet Recalls Hip Prosthesis Components Due to Sterilant Biocompatibility Concerns
FDA (Devices) · 2020-11-11
- HighZimmer Biomet Recalls Hip Prosthesis Component Due to Sterilant Concerns
FDA (Devices) · 2020-11-11
Same hazard · instrument fracture
See all →- HighZimmer Biomet Recalls 1.0mm Drill Bits Due to Fracture Risk
FDA (Devices) · 2018-02-14
- HighZimmer Biomet Recalls Herbert Cannulated Bone Screw System Drills
FDA (Devices) · 2017-10-04
- HighZimmer Biomet Recalls Orthopedic Drill Bits Due to Fracture Risk
FDA (Devices) · 2017-10-04
- SevereZimmer Biomet Recalls Orthopedic Drill Bits Due to Fracture Risk
FDA (Devices) · 2017-10-04
- HighZimmer Biomet Recalls Orthopedic Drill Bits Due to Fracture Risk
FDA (Devices) · 2017-10-04
Similar recalls
- HighZimmer Biomet Recalls 1.0mm Drill Bits Due to Fracture Risk
FDA (Devices) · 2018-02-14
- ModerateZimmer Biomet Recalls Mislabeled Periarticular Locking Plate System Screws
FDA (Devices) · 2016-01-20
- HighZimmer Biomet Recalls Spinal Rod Cutters Due to Fracture Risk
FDA (Devices) · 2020-12-30
- ModerateZimmer Biomet Recalls Orthopedic Plates Due to Labeling Mismatch
FDA (Devices) · 2016-01-20
- HighZimmer Periarticular Locking Plate recalled due to thread form defect
FDA (Devices) · 2023-08-09
- HighZimmer Distal Lateral Fibular Plate Recall: Locking Screw Malfunction Risk
FDA (Devices) · 2024-05-08