65 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
65
Critical
0
Severe
20
Most recent
2018-02-14

Of the 65 instrument fracture recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 20 (31%) are Severe.

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all instrument fracture recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

1–25 of 65

  • HighFDA (Devices)·Z-0516-2018·2018-02-14

    Zimmer Biomet Recalls 1.0mm Drill Bits Due to Fracture Risk

    Zimmer Biomet is recalling 1,524 non-sterile 1.0mm drill bits because a raw material anomaly may increase the risk of instrument fracture.

    Product
    DRILL BIT MINI QUICK CONNECT 1.0MM, REF 2312-20-200 & 2312-20-202, NON STERILE
    Category
    Medical Device
    Distribution
    35 states
  • SevereFDA (Devices)·Z-3164-2017·2017-10-04

    Zimmer Biomet Recalls ECT Internal Fracture Fixation Drills

    Zimmer Biomet is recalling 4,423 ECT Internal Fracture Fixation Drills because raw material anomalies may increase the risk of instrument fracture during use.

    Product
    ECT Internal Fracture Fixation Drill 2.0 mm Diameter (.079 Inch), Item Number/EDI 00231802000, Nonsterile. orthopedic surgical instrument.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-3181-2017·2017-10-04

    Zimmer Biomet Recalls Orthopedic Surgical Drills and Screw Taps

    Zimmer Biomet is recalling 1,129 orthopedic surgical drills and screw taps due to raw material anomalies that may increase the risk of instrument fracture.

    Product
    Zimmer Periarticular Locking Plate System Drill Standard 2.7 mm Diameter, Item Number/EDI 00236020527, Nonsterile. orthopedic surgical instrument.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-3183-2017·2017-10-04

    Zimmer Biomet Recalls Orthopedic Drill Bits Due to Fracture Risk

    Zimmer Biomet is recalling specific orthopedic drill bits and screw taps because raw material anomalies may cause the instruments to fracture during use.

    Product
    ECT Internal Fracture Fixation Quick-Connect Drill 2.0 mm Diameter 12.5 cm Length, Item Number/EDI 00241002100, Nonsterile. orthopedic surgical instrument.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-3151-2017·2017-10-04

    Zimmer Biomet Recalls Orthopedic Surgical Drill Bits and Screw Taps

    Zimmer Biomet is recalling specific orthopedic surgical instruments due to a raw material anomaly that may increase the risk of instrument fracture during use.

    Product
    Zimmer Natural Nail System Calibrated Drill Long 4.3mm, Item Number/EDI 00249004443, Nonsterile. orthopedic surgical instrument.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-3196-2017·2017-10-04

    Zimmer Biomet Recalls Orthopedic Drill Bits Due to Fracture Risk

    Zimmer Biomet is recalling specific orthopedic drill bits and screw taps because raw material anomalies may increase the risk of instrument fracture during use.

    Product
    Drill Bit Quick-Connect 3.5 mm Diameter 110 mm Length, Item Number/EDI 00480611035, Nonsterile. orthopedic surgical instrument.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-3175-2017·2017-10-04

    Zimmer Biomet Recalls Straight Shank Drill Bits Due to Fracture Risk

    Zimmer Biomet is recalling 62 units of 4.0 mm Straight Shank Drill Bits because raw material anomalies may increase the risk of instrument fracture during use.

    Product
    Straight Shank Drill Bits 4.0 mm Diameter, Item Number/EDI 00231804006, Nonsterile. orthopedic surgical instrument.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-3202-2017·2017-10-04

    Zimmer Biomet Recalls Orthopedic Drill Bits Due to Fracture Risk

    Zimmer Biomet is recalling 150 nonsterile orthopedic drill bits because raw material anomalies may cause the instruments to fracture during use.

    Product
    Drill Bit Quick-Connect 4.5 mm Diameter 145 mm Length, Item Number/EDI 00480614545, Nonsterile. orthopedic surgical instrument.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-3199-2017·2017-10-04

    Zimmer Biomet Recalls Orthopedic Drill Bits Due to Fracture Risk

    Zimmer Biomet is recalling 15 nonsterile orthopedic drill bits because raw material anomalies may increase the risk of instrument fracture during use.

    Product
    Drill Bit Quick-Connect 3-Fluted 4.5 mm Diameter 195 mm Length, Item Number/EDI 00480719545, Nonsterile. orthopedic surgical instrument.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-3167-2017·2017-10-04

    Zimmer Biomet Recalls ECT Internal Fixation Drill Bits Due to Fracture Risk

    Zimmer Biomet is recalling ECT Internal Fixation Drill Bits because raw material anomalies may cause the instruments to fracture during use.

    Product
    ECT Internal Fixation Drill Bits 2.5 mm Diameter (0.98 Inch), Item Number/EDI 00231802506, Nonsterile. orthopedic surgical instrument.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-3158-2017·2017-10-04

    Zimmer Biomet Recalls M/DN Intramedullary Fixation Distal Drill Pilot Tips

    Zimmer Biomet is recalling 182 M/DN Intramedullary Fixation Distal Drill Pilot Tips due to raw material anomalies that may increase the risk of instrument fracture.

    Product
    M/DN Intramedullary Fixation Distal Drill Pilot Tip 3.2 mm Diameter, Item Number/EDI 00225503332, Nonsterile. orthopedic surgical instrument.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-3187-2017·2017-10-04

    Zimmer Biomet Recalls ECT Quick-Connect Drills Due to Fracture Risk

    Zimmer Biomet is recalling 62 ECT Internal Fracture Fixation Quick-Connect Drills because raw material anomalies may cause the instruments to fracture during use.

    Product
    ECT Internal Fracture Fixation Quick-Connect Drill 3.5 mm Diameter 11 cm Length, Item Number/EDI 00241003500, Nonsterile. orthopedic surgical instrument.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-3191-2017·2017-10-04

    Zimmer Biomet Recalls Orthopedic Drill Bits Due to Fracture Risk

    Zimmer Biomet is recalling specific orthopedic drill bits and screw taps because raw material anomalies may cause the instruments to fracture during use.

    Product
    Drill Bit Jacobs Chuck 3.2 mm Diameter 130 mm Length, Item Number/EDI 00480513032, Nonsterile. orthopedic surgical instrument.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-3188-2017·2017-10-04

    Zimmer Biomet Recalls ECT Internal Fracture Fixation Quick-Connect Drill Bits

    Zimmer Biomet is recalling 10 units of ECT Internal Fracture Fixation Quick-Connect Drills due to a raw material anomaly that may increase the risk of instrument fracture during use.

    Product
    ECT Internal Fracture Fixation Quick-Connect Drill 4.0 mm Diameter 20cm Length, Item Number/EDI 00241004000, Nonsterile. orthopedic surgical instrument.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-3157-2017·2017-10-04

    Zimmer Biomet Recalls NCB Periprosthetic Plate System Drill Bits

    Zimmer Biomet is recalling 185 NCB Periprosthetic Plate System Drill Bits due to a raw material anomaly that may increase the risk of instrument fracture during use.

    Product
    NCB Periprosthetic Plate System Drill Bit With Quick-Coupling 4.5 mm Diameter 195 mm Length, Item Number/EDI 0200024330, Nonsterile. orthopedic surgical instrument.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-3150-2017·2017-10-04

    Zimmer Biomet Recalls ECT Internal Fracture Fixation Quick-Connect Drills

    Zimmer Biomet is recalling 4 units of ECT Internal Fracture Fixation Quick-Connect Drills due to raw material anomalies that may increase the risk of instrument fracture.

    Product
    ECT Internal Fracture Fixation Quick-Connect Drill, 1.5 mm Diameter, 85mm Length, Item Number/EDI 00241001500, Nonsterile. orthopedic surgical instrument.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-3178-2017·2017-10-04

    Zimmer Biomet Recalls Orthopedic Screw Taps Due to Material Anomaly

    Zimmer Biomet is recalling 198 nonsterile orthopedic screw taps because raw material anomalies may increase the risk of instrument fracture during use.

    Product
    Zimmer Periarticular Locking Plate System, Locking Screw Tap Standard Quick-Connect 3.5 mm Diameter, Item Number/EDI 00236015335, Nonsterile. orthopedic surgical instrument.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-3160-2017·2017-10-04

    Zimmer Biomet Recalls Orthopedic Surgical Instruments Due to Fracture Risk

    Zimmer Biomet is recalling 21 units of M/DN Intramedullary Fixation Femoral Drills because raw material anomalies may cause the instruments to fracture during use.

    Product
    M/DN Intramedullary Fixation Femoral Drill Large 5.0 mm Item Number/EDI 00225503550, Nonsterile. orthopedic surgical instrument.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-3180-2017·2017-10-04

    Zimmer Biomet Recalls Orthopedic Surgical Drills Due to Fracture Risk

    Zimmer Biomet is recalling 1,091 nonsterile orthopedic surgical drills and screw taps because raw material anomalies may cause instrument fracture.

    Product
    Zimmer Periarticular Locking Plate System Drill Standard 2.0 mm Diameter, Item Number/EDI 00236017520, Nonsterile. orthopedic surgical instrument.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-3193-2017·2017-10-04

    Zimmer Biomet Recalls Orthopedic Drill Bits Due to Fracture Risk

    Zimmer Biomet is recalling specific orthopedic drill bits and screw taps because a raw material anomaly may increase the risk of instrument fracture during use.

    Product
    Drill Bit Quick-Connect 2.0 mm Diameter 100 mm Length, Item Number/EDI 00480610020, Nonsterile. orthopedic surgical instrument.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3162-2017·2017-10-04

    Zimmer Biomet Recalls ECT Internal Fracture Fixation Drills Due to Material Anomaly

    Zimmer Biomet is recalling 1,999 ECT Internal Fracture Fixation Drills because raw material anomalies may increase the risk of instrument fracture during use.

    Product
    ECT Internal Fracture Fixation Drill 1.5 mm Diameter (.059 Inch), Item Number/EDI 00231801500, Nonsterile. orthopedic surgical instrument.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3200-2017·2017-10-04

    Zimmer Biomet Recalls Orthopedic Drill Bits Due to Fracture Risk

    Zimmer Biomet is recalling 453 nonsterile orthopedic drill bits because raw material anomalies may cause instrument fracture during use.

    Product
    Drill Bit Quick-Connect Calibrated 3-Fluted 2.5 mm Diameter 230 mm Length, Item Number/EDI 00480723025, Nonsterile. orthopedic surgical instrument.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3156-2017·2017-10-04

    Zimmer Biomet Recalls ECT Internal Fracture Fixation Long Drills

    Zimmer Biomet is recalling 10 units of ECT Internal Fracture Fixation Long Drills due to raw material anomalies that may increase the risk of instrument fracture.

    Product
    ECT Internal Fracture Fixation Long Drill, 6.4 mm (1/4 Inch) Diameter 20.3 cm(8 Inch) Length, Item Number/EDI 00129100406, Nonsterile. orthopedic surgical instrument.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3170-2017·2017-10-04

    Zimmer Biomet Recalls ECT Internal Fracture Fixation Drill Bits

    Zimmer Biomet is recalling 1,255 ECT Internal Fracture Fixation Drill Bits due to raw material anomalies that may increase the risk of instrument fracture during use.

    Product
    ECT Internal Fracture Fixation Drill 3.2 mm Diameter (.126 Inch), Item Number/EDI 00231803200, Nonsterile. orthopedic surgical instrument.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3147-2017·2017-10-04

    Zimmer Biomet Recalls M/DN Intramedullary Fixation Femoral Drill Bits

    Zimmer Biomet is recalling 25 units of M/DN Intramedullary Fixation Femoral Drills due to raw material anomalies that may increase the risk of instrument fracture during use.

    Product
    M/DN Intramedullary Fixation Femoral Drill 3.7 mm Diameter Replaces 2255-08-32, Item Number/EDI 00225503137, Nonsterile. orthopedic surgical instrument.
    Category
    Medical Device
    Distribution
    Distributed nationwide